UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Mika
 
Posts: n/a
Default C/H Boiler Conversion

Dear All,

Just thinking about converting my cast-iron boiler system to a
combi/condensing boiler.

I have the Vaillant EcoMax 835 (120,000 BTU).

Questions...
1) Anyone got this boiler? If so, any feedback?
2) Costs for conversion of open-vent to closed system (London)?
3) Any other issues?

Any comments (constructive) would be greatly received.

Mika
  #2   Report Post  
Christian McArdle
 
Posts: n/a
Default C/H Boiler Conversion

2) Costs for conversion of open-vent to closed system (London)?

Is this DIY or paying?

Provided that the system is up to the increased pressure, it is a very
simple job. You remove the old tanks and cap off the old feed/vent. You add
the pressure vessel, filling loop, pressure relief valve/pipework and
pressure gauge. That's it. Normally, the majority (or all) of these
components come ready fitted and plumbed in the new boiler. You just stick
the pressure relief pipe out of the wall and connect it up, ensuring it
terminates at a safe location.

BTW, the 835 is a combi boiler. Is this what you want? Your old system is
probably a storage one. If you like baths, you might want to keep the
storage system. However, the combi side will be better for showers. OTOH,
some high output combis are unable to modulate down particularly low, which
counts against them as they will cycle when doing the central heating.

Christian.



  #3   Report Post  
Ed Sirett
 
Posts: n/a
Default C/H Boiler Conversion

On Mon, 19 Jan 2004 03:51:59 +0000, Mika wrote:

Dear All,

Just thinking about converting my cast-iron boiler system to a
combi/condensing boiler.

I have the Vaillant EcoMax 835 (120,000 BTU).

Questions...
1) Anyone got this boiler? If so, any feedback?
2) Costs for conversion of open-vent to closed system (London)?
3) Any other issues?

Any comments (constructive) would be greatly received.


Other posters seem to have covered the points.
Professionally you would be looking at about boiler + 1000
(+VAT if the fitter is VAT registered).
These boilers are about 1100 quid with the flue +VAT.

So I would expect about just over 2000 all in.
BG will be about 3000.


--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Boiler kettling? David Hearn UK diy 5 January 1st 04 07:47 PM
Gas boiler service review/advice David Hearn UK diy 1 November 18th 03 04:21 PM
Replacing a boiler David Hearn UK diy 38 November 12th 03 11:10 PM
Digital cylinder 'stat? Martin Angove UK diy 9 October 12th 03 08:32 PM
New Combi boiler GB UK diy 7 September 7th 03 11:34 PM


All times are GMT +1. The time now is 09:55 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"