Hi,



Some readers may remember a couple of weeks ago I asked about adding a
wireless room stat to an existing system (S plan, 7 day timer, independent
hot water and heating)



Based upon the very helpful advice from this group I've now installed the
Honeywell CM67-RF unit (87 quid from rkm-heating-controls BTW). This unit is
a 7 day wireless programmable room stat and means I don't use the existing
timer to control the heating at all but I've left the existing timer to
control the hot water.



I have now wired it all together but there's a problem.



Test 1 - test heating only using the CM67

Power on, go to manual and it's good news. The heating works fine, the
boiler fires, the pump whirs, radiators get hot and the CM67 is happy to
control it. I've still to program the unit but that can wait.



Test 2 - test water only using the existing timer

Power on and the existing timer is working so I set the time and day and
switch the unit to constantly heat the hot water. The hot water light on the
timer comes on but nothing else happens, no boiler, no pump, no valve
action. Oh dear.



Test 3 - wire the heating back to how it was, into the old timer unit, to
make sure something hasn't broken (lose wire etc.) during installation.

Both heating and water work together and independently fine - just like it
use to.



Here's the old wiring into the existing timer from left to right
http://www.jjh1.demon.co.uk/wiring2.jpg



Pin 0 - earth (green and yellow) x2

Pin 1 - neutral (blue)

Pin 2 - live (brown)

Pin 3 - ON (brown)

Pin 4 - C (jumper wire from pin 2)

Pin 5 - OFF (no wire)

Pin 6 - ON (blue)

Pin 7 - C (jumper wire from pin 2)

Pin 8 - OFF (no wire)



I worked out which ON wire controlled the heating by disconnecting each ON
wire in turn. It turns out the brown wire on Pin 3 controls the heating.



For the new wiring I've simpled wired the brown wire on Pin 3 into the new
unit.



Now I'm confused as to why in the new set up the heating works but the water
doesn't. Any ideas?




Thanks in advance



Jules



PS - I've left the CH wired back into the existing timer to get heating and
water to work.


 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Wireless Room Stats - Any good? Mike Hibbert UK diy 7 January 9th 04 04:53 PM
Adding a wireless room thermostat JH UK diy 14 January 5th 04 04:17 PM
Are room thermostats out of fashion? stuart noble UK diy 143 December 24th 03 01:19 AM
Room thermostat Mihai UK diy 2 November 5th 03 09:45 PM
HWCH : Thermostat for one room Frank Z UK diy 3 July 31st 03 11:19 AM


All times are GMT +1. The time now is 11:47 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"