  #1   Report Post  
Martin
 
Posts: n/a
Default Cold Water Storage Tank

To comply with the warrenty of a shower pump I have to replace my 25
gallon water tank in the loft with a 50 gallon. I've read lots of
postings on this subject.

I've read somewhere that in a year or two new regs will require a dry
loft for new builds. There is always a good reason regs are changed
and therefore although I do not have a new build I do like to be
compliant.

Therefore my question is what soultions are available to achieve a dry
loft? I will not consider a combi bolier solution, mainly because
there is no backup for hot water should it fail, and unless you have
good reliable mains pressure power showers are out of the question.
Ideally I'd like to store my cold water downstairs in the utility
room, ofcourse this would not work with a standard tank as there would
be no pressure for taps above the tank etc etc.

Thanks in adavnce for your advice.

Regards,
Martin.
  #2   Report Post  
Grunff
 
Posts: n/a
Default Cold Water Storage Tank

Martin wrote:

Therefore my question is what soultions are available to achieve a dry
loft? I will not consider a combi bolier solution, mainly because
there is no backup for hot water should it fail, and unless you have
good reliable mains pressure power showers are out of the question.
Ideally I'd like to store my cold water downstairs in the utility
room, ofcourse this would not work with a standard tank as there would
be no pressure for taps above the tank etc etc.



We have a thermal store, and we're very happy with it. It's a
single cylinder, with a built in header tank. The water in the
cylinder is heated directly by the boiler, and circulated
through the radiators. Hot water is achieved by passing cold
mains water through a heat exchanger coil housed within the
cylinder (some systems use a plate exchanger, which is in some
ways better).

The system is simple, and has many advantages over non-store
setups. The main one is the large energy buffering capacity,
which allows long, continuous boiler burns.

--
Grunff

  #3   Report Post  
Will Dean
 
Posts: n/a
Default Cold Water Storage Tank

"Martin" wrote in message
om...

I've read somewhere that in a year or two new regs will require a dry
loft for new builds. There is always a good reason regs are changed


I just can't let that pass.

The overwhelming reason for regs to change is that there are vast
departments of people who's job it is to create new regulations and still
others who's job it is to enforce them. If they didn't keep changing the
rules, they'd have nothing to do.

Therefore my question is what soultions are available to achieve a dry
loft? I will not consider a combi bolier solution, mainly because
there is no backup for hot water should it fail, and unless you have
good reliable mains pressure power showers are out of the question.
Ideally I'd like to store my cold water downstairs in the utility
room, ofcourse this would not work with a standard tank as there would
be no pressure for taps above the tank etc etc.


I'd put a tank in the roof, and achieve karmic compliance-bliss by fitting
every bit of clobber going to make it comply with the water by-laws. You'll
be able to delight in fitting little strainer to stop insects coming up the
overflow *AND* spend time calculating the flow resistance of said strainer
to make sure it doesn't impede any possible overflow.

Then you can worry about whether there's enough insulation around/over the
tank (and did that lid clip on nicely?) and whether you've left a sufficient
gap in the insulation underneath it - while still making sure it's properly
supported.

If you're going to store cold water, which might be a good idea if your
mains flow-rate is poor, then the best place to put it is where gravity can
deliver it back to the rest of the house.

HTH,

Will




  #4   Report Post  
Andy Hall
 
Posts: n/a
Default Cold Water Storage Tank

On 28 Dec 2003 13:13:17 -0800, (Martin) wrote:

To comply with the warrenty of a shower pump I have to replace my 25
gallon water tank in the loft with a 50 gallon. I've read lots of
postings on this subject.

I've read somewhere that in a year or two new regs will require a dry
loft for new builds.


Really? News to me. I was talking to somebody at WRAS a couple of
weeks ago on a similar subject and this didn't come up.


There is always a good reason regs are changed
and therefore although I do not have a new build I do like to be
compliant.


There is a trend anyway to fit combi boilers into some types of new
build property simply to be able to de-skill the plumbing operation.

However, in a new property it is possible to easily provision an
adequate mains water supply. This may not be so easy in an older
property, so before rushing off to chase imaginary regulations, do
check the mains water supply to make sure that it is adequate.


Therefore my question is what soultions are available to achieve a dry
loft? I will not consider a combi bolier solution, mainly because
there is no backup for hot water should it fail, and unless you have
good reliable mains pressure power showers are out of the question.


The only way to meet the backup requirement is through some form of
storage - none of the mains fed hot water systems inherently do that.

In terms of mains fed hot water systems, apart from combi boilers you
can have a pressurised hot water cylinder - stores the hot water and
is heated via a coil similar to an open vented system - or a thermal
store where the bulk water is heated directly or indirectly by the
boiler and that is pumped through an efficient heat exchanger when
required. Both of these get you over the rate of heating problem of
low to mid range combi boilers in that they store the hot water or the
energy to heat it.

However, they are only as good as the mains supply.

Having said that, there are on the market, pressurised water storage
vessels. IIRC, these operate on a similar principle to the pressure
vessels used in sealed CH systems- i.e. with a diaphragm with air or
nitrogen on one side, water on the other. The application is for
where the static pressure of the supply is OK but the flow rate poor,
and there is a requirement for periodically large amounts of water.
I believe that these can be fitted on a ground floor - I tried to find
the manufacturer, but can't for the moment. ISTR them being quite
expensive, however.



Ideally I'd like to store my cold water downstairs in the utility
room, ofcourse this would not work with a standard tank as there would
be no pressure for taps above the tank etc etc.

Thanks in adavnce for your advice.

Regards,
Martin.


..andy

To email, substitute .nospam with .gl
  #5   Report Post  
Chris J Dixon
 
Posts: n/a
Default Cold Water Storage Tank

Andy Hall wrote:

However, in a new property it is possible to easily provision an
adequate mains water supply. This may not be so easy in an older
property, so before rushing off to chase imaginary regulations, do
check the mains water supply to make sure that it is adequate.


The only way to meet the backup requirement is through some form of
storage - none of the mains fed hot water systems inherently do that.

In terms of mains fed hot water systems, apart from combi boilers you
can have a pressurised hot water cylinder - stores the hot water and
is heated via a coil similar to an open vented system - or a thermal
store where the bulk water is heated directly or indirectly by the
boiler and that is pumped through an efficient heat exchanger when
required. Both of these get you over the rate of heating problem of
low to mid range combi boilers in that they store the hot water or the
energy to heat it.

However, they are only as good as the mains supply.

Having said that, there are on the market, pressurised water storage
vessels. IIRC, these operate on a similar principle to the pressure
vessels used in sealed CH systems- i.e. with a diaphragm with air or
nitrogen on one side, water on the other. The application is for
where the static pressure of the supply is OK but the flow rate poor,
and there is a requirement for periodically large amounts of water.
I believe that these can be fitted on a ground floor - I tried to find
the manufacturer, but can't for the moment. ISTR them being quite
expensive, however.

This has been suggested to me:
http://www.gah.co.uk/GAH_Dualstream/frameset.htm

No idea about cost though. I also note that the diaphragm only
has a 2-year warranty.

Alternatively, you could have a break tank in the garage, mounted
above a single feed pump.

Chris
--
Chris J Dixon Nottingham UK


Have dancing shoes, will ceilidh.


  #6   Report Post  
G&M
 
Posts: n/a
Default Cold Water Storage Tank


"Martin" wrote in message
I've read somewhere that in a year or two new regs will require a dry
loft for new builds. There is always a good reason regs are changed
and therefore although I do not have a new build I do like to be
compliant.


If they are going to enforce dry lofts they would need to first enforce our
water companies to deliver water under some sort of pressure 24 hours/day.
I'm okay but a friend's system drops to almost nothing at peak times so
things like the shower becomes unusable.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Contemplating unvented Indirect hot water upgrade vortex2 UK diy 21 December 4th 03 12:51 AM
No Cold Water Header Tank - Is this a problem? Chris UK diy 9 December 3rd 03 09:51 PM
how do I ensure there is a cold water path to the boilers return BigWallop UK diy 0 July 3rd 03 02:59 PM


All times are GMT +1. The time now is 06:18 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"