Tumble Dryer Vent
I am remodelling my kitchen and the most logical place for the tumble dryer
is against an internal wall. Can it be vented up and out a flat roof. The washing machine can empty the waste water into the soil pipe in a planned toilet/shower room. I planned to vent the toilet out through the flat roof so was wondering if the tumble dryer can vent out the same place. I need to ensure that the hot air from the tumble dryer doesn't vent back into the toilet. Kevin. |
#2
Posted to uk.d-i-y
|
|||
|
|||
Tumble Dryer Vent
Zen83237 wrote:
I am remodelling my kitchen and the most logical place for the tumble dryer is against an internal wall. Can it be vented up and out a flat roof. The washing machine can empty the waste water into the soil pipe in a planned toilet/shower room. I planned to vent the toilet out through the flat roof so was wondering if the tumble dryer can vent out the same place. I need to ensure that the hot air from the tumble dryer doesn't vent back into the toilet. Never a good idea to have vents like this through a flat roof; lots of scope for leaks. Certainly possible though. Pretty sure you wouldn't be allowed to combine the toilet and tumble-drier vents but Building Regs gurus here may know better. My first thought though is are you sure you need the vent even for the toilet - ie, have you looke into the possibility of fitting it with an air-admittance valve instead? http://www.screwfix.com/prods/78150/Plumbing/Soil-Vent/FloPlast-Push-Fit-Air-Admittance-Valve-Grey?cm_re=SEARCHPROMO-_-AIR-ADMITTANCE-_-78150 May or may not be possible depending on various factors; however maybe you've already been down this road? David |
#3
Posted to uk.d-i-y
|
|||
|
|||
Tumble Dryer Vent
"Lobster" wrote in message ... Zen83237 wrote: I am remodelling my kitchen and the most logical place for the tumble dryer is against an internal wall. Can it be vented up and out a flat roof. The washing machine can empty the waste water into the soil pipe in a planned toilet/shower room. I planned to vent the toilet out through the flat roof so was wondering if the tumble dryer can vent out the same place. I need to ensure that the hot air from the tumble dryer doesn't vent back into the toilet. Never a good idea to have vents like this through a flat roof; lots of scope for leaks. Certainly possible though. Pretty sure you wouldn't be allowed to combine the toilet and tumble-drier vents but Building Regs gurus here may know better. My first thought though is are you sure you need the vent even for the toilet - ie, have you looke into the possibility of fitting it with an air-admittance valve instead? http://www.screwfix.com/prods/78150/Plumbing/Soil-Vent/FloPlast-Push-Fit-Air-Admittance-Valve-Grey?cm_re=SEARCHPROMO-_-AIR-ADMITTANCE-_-78150 May or may not be possible depending on various factors; however maybe you've already been down this road? David This is a medium to long term plan that will involve building a kitchen extention and toilet shower room. I am trying to visualise the options before getting any plans done. I don't quite understand how the air admittance valve works so I need to look into that. I have a cooker hood extracting through a flat roof and that is ok. Kevin |
#4
Posted to uk.d-i-y
|
|||
|
|||
Tumble Dryer Vent
Zen83237 wrote:
I am remodelling my kitchen and the most logical place for the tumble dryer is against an internal wall. Can it be vented up and out a flat roof. The washing machine can empty the waste water into the soil pipe in a planned toilet/shower room. I planned to vent the toilet out through the flat roof so was wondering if the tumble dryer can vent out the same place. I need to ensure that the hot air from the tumble dryer doesn't vent back into the toilet. Kevin. instead of spending a fortune on venting the existing TD, why not just purchase a condensing one? About £150ish. If you start knocking holes out of a flat roof, it's likely to end up costing you many hundreds of pounds. |
#5
Posted to uk.d-i-y
|
|||
|
|||
Tumble Dryer Vent
Zen83237 wrote:
"Lobster" wrote in message ... Zen83237 wrote: I am remodelling my kitchen and the most logical place for the tumble dryer is against an internal wall. Can it be vented up and out a flat roof. The washing machine can empty the waste water into the soil pipe in a planned toilet/shower room. I planned to vent the toilet out through the flat roof so was wondering if the tumble dryer can vent out the same place. I need to ensure that the hot air from the tumble dryer doesn't vent back into the toilet. Never a good idea to have vents like this through a flat roof; lots of scope for leaks. Certainly possible though. Pretty sure you wouldn't be allowed to combine the toilet and tumble-drier vents but Building Regs gurus here may know better. My first thought though is are you sure you need the vent even for the toilet - ie, have you looke into the possibility of fitting it with an air-admittance valve instead? http://www.screwfix.com/prods/78150/Plumbing/Soil-Vent/FloPlast-Push-Fit-Air-Admittance-Valve-Grey?cm_re=SEARCHPROMO-_-AIR-ADMITTANCE-_-78150 May or may not be possible depending on various factors; however maybe you've already been down this road? This is a medium to long term plan that will involve building a kitchen extention and toilet shower room. I am trying to visualise the options before getting any plans done. I don't quite understand how the air admittance valve works so I need to look into that. Where conventionally you would have a soil stack venting upwards, you'd basically cap it off with an AAV rather than have it go up through the roof. It uses the fact that you don't (necessarily) need to let air *out* of the system, but you do need to let air *in* to avoid vaccuum formation and the toilet not flushing etc. The AAV is a one-way valve which lets that happen, ie without letting gas out of sewer into your house; and would be a no-brainer in your scenario provided it's appropriate... there are several conditions eg you can't be at the end of the run of your sewer; at least every 3 or 4 houses(?) has to have a fully open vent etc. David |
#6
Posted to uk.d-i-y
|
|||
|
|||
Tumble Dryer Vent
Zen83237 wrote: I am remodelling my kitchen and the most logical place for the tumble dryer is against an internal wall. Can it be vented up and out a flat roof. The washing machine can empty the waste water into the soil pipe in a planned toilet/shower room. I planned to vent the toilet out through the flat roof so was wondering if the tumble dryer can vent out the same place. I need to ensure that the hot air from the tumble dryer doesn't vent back into the toilet. I'd be rather more concerned that the toilet smells didn't get back into the tumble drier :-) -- Dave - The Medway Handyman www.medwayhandyman.co.uk |
#7
Posted to uk.d-i-y
|
|||
|
|||
Tumble Dryer Vent
On 30 May, 18:44, Lobster wrote:
Zen83237 wrote: I planned to vent the toilet out through the flat roof so was wondering if the tumble dryer can vent out the same place. My first thought though is are you sure you need the vent even for the toilet - ie, have you looke into the possibility of fitting it with an air-admittance valve instead? By 'vent the toilet' does the OP mean 'vent the stack,' or 'vent the WC extractor'? Might make a wee bit of difference to answers around combining the two. J |
#8
Posted to uk.d-i-y
|
|||
|
|||
Tumble Dryer Vent
Zen83237 wrote: I am remodelling my kitchen and the most logical place for the tumble dryer is against an internal wall. Can it be vented up and out a flat roof. snip I'd be concerned about such a long vertical run: what would happen to any water that condenses out of the exhaust stream? And as others have said, the complications of a long-term weather-proof hole in a flat roof do not appeal. Sounds like a case for a condensing drier. -- Kevin Poole ****Use current date to reply (e.g. )**** |
#9
Posted to uk.d-i-y
|
|||
|
|||
Tumble Dryer Vent
Kevin Poole wrote:
Zen83237 wrote: I am remodelling my kitchen and the most logical place for the tumble dryer is against an internal wall. Can it be vented up and out a flat roof. snip I'd be concerned about such a long vertical run: what would happen to any water that condenses out of the exhaust stream? Self-flushing toilet? ;-) David |
#10
Posted to uk.d-i-y
|
|||
|
|||
Tumble Dryer Vent
wrote in message ... On 30 May, 18:44, Lobster wrote: Zen83237 wrote: I planned to vent the toilet out through the flat roof so was wondering if the tumble dryer can vent out the same place. My first thought though is are you sure you need the vent even for the toilet - ie, have you looke into the possibility of fitting it with an air-admittance valve instead? By 'vent the toilet' does the OP mean 'vent the stack,' or 'vent the WC extractor'? Might make a wee bit of difference to answers around combining the two. J Yes, I mean vent the room. I should also point out that the existing soil pipe to the upstairs bathroom will have to go through the flat roof. The wc can discharge into the existing soil pipe. Kevin |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Vented tumble dryer with vent on right rather than at back - does it exist? | UK diy | |||
Tumble Dryer Condenser Vent Kit | UK diy | |||
Help With Tumble Dryer | UK diy | |||
Tumble dryer vent | UK diy | |||
tumble dryer which? | UK diy |