Knocking down a load bearing wall
We want to knock down the wall between kitchen and dining room. Today
the civil engineer man came round to inspect and give us the dimensions for the Universal Beam. He checked in the loft and the dividing wall is not supporting the roof - which is good. I've done plenty of diy jobs and we have done one house restoration but not knocking down a supporting wall.. I'd like to take on this job and have help available to place the UB. Question is - how difficult is it? Anybody out there done this kind of thing and can give me any tips or advice? |
#2
Posted to uk.d-i-y
|
|||
|
|||
Knocking down a load bearing wall
"Pete L" wrote in message
ups.com... We want to knock down the wall between kitchen and dining room. Today the civil engineer man came round to inspect and give us the dimensions for the Universal Beam. He checked in the loft and the dividing wall is not supporting the roof - which is good. I've done plenty of diy jobs and we have done one house restoration but not knocking down a supporting wall.. I'd like to take on this job and have help available to place the UB. Question is - how difficult is it? Anybody out there done this kind of thing and can give me any tips or advice? This makes it seem easy http://www.houseprofessionals.com/di...ing_a_wall.htm |
#3
Posted to uk.d-i-y
|
|||
|
|||
Knocking down a load bearing wall
Pete L wrote:
We want to knock down the wall between kitchen and dining room. Today the civil engineer man came round to inspect and give us the dimensions for the Universal Beam. He checked in the loft and the dividing wall is not supporting the roof - which is good. I've done plenty of diy jobs and we have done one house restoration but not knocking down a supporting wall.. I'd like to take on this job and have help available to place the UB. Question is - how difficult is it? Anybody out there done this kind of thing and can give me any tips or advice? 25 years ago when we moved here I took down the wall between the lounge & dining room. Had to put in an RSJ. Did the calcs myself (pre internet days), got Building Control to approve. Took a weekend to do the job. Acro props are a must obviously. These days you can also hire Strong Boys http://www.knighton-tools.co.uk/acat..._Supports.html Biggest problem was cutting away the brickwork after installing the RSJ, used a mains angle grinder/cut off saw from a local hire shop. Dust simply unbelievable. Really. You cannot imagine it until you have done it. Panic buy dust masks! Also try taping off all doors etc. We found dust in unexpected areas for about 2 months afterwards. Slight difference in floor levels when the wall was cut away, be prepared for that. Still there 25 years later. Well within the capacity of a DIY guy, does need two of you at least. 5 years ago SWMBO decided a through lounge was a bad idea, so I put up a stud partition :-) -- Dave - The Medway Handyman www.medwayhandyman.co.uk 01634 717930 07850 597257 |
#4
Posted to uk.d-i-y
|
|||
|
|||
Knocking down a load bearing wall
On 13 Nov, 23:27, "The Medway Handyman"
wrote: Pete L wrote: We want to knock down the wall between kitchen and dining room. Today the civil engineer man came round to inspect and give us the dimensions for the Universal Beam. He checked in the loft and the dividing wall is not supporting the roof - which is good. I've done plenty of diy jobs and we have done one house restoration but not knocking down a supporting wall.. I'd like to take on this job and have help available to place the UB. Question is - how difficult is it? Anybody out there done this kind of thing and can give me any tips or advice? 25 years ago when we moved here I took down the wall between the lounge & dining room. Had to put in an RSJ. Did the calcs myself (pre internet days), got Building Control to approve. Took a weekend to do the job. Acro props are a must obviously. These days you can also hire Strong Boyshttp://www.knighton-tools.co.uk/acatalog/Masonry_Supports.html Biggest problem was cutting away the brickwork after installing the RSJ, used a mains angle grinder/cut off saw from a local hire shop. Dust simply unbelievable. Really. You cannot imagine it until you have done it. Panic buy dust masks! Also try taping off all doors etc. We found dust in unexpected areas for about 2 months afterwards. Slight difference in floor levels when the wall was cut away, be prepared for that. Still there 25 years later. Well within the capacity of a DIY guy, does need two of you at least. 5 years ago SWMBO decided a through lounge was a bad idea, so I put up a stud partition :-) -- Dave - The Medway Handymanwww.medwayhandyman.co.uk 01634 717930 07850 597257 Thanks for your advice. The sledgehammers will start swinging next Friday. I have the UB on order. It weighs nearly 200kg but hopefully with three of us we'll be able to slip the little blighter into place! We have dust masks for cutting the brickwork and will be sealing all doors....... |
#5
Posted to uk.d-i-y
|
|||
|
|||
Knocking down a load bearing wall
On 1 Dec, 09:33, Pete L wrote:
On 13 Nov, 23:27, "The Medway Handyman" wrote: Pete L wrote: We want to knock down the wall between kitchen and dining room. Today the civil engineer man came round to inspect and give us the dimensions for the Universal Beam. He checked in the loft and the dividing wall is not supporting the roof - which is good. I've done plenty of diy jobs and we have done one house restoration but not knocking down a supporting wall.. I'd like to take on this job and have help available to place the UB. Question is - how difficult is it? Anybody out there done this kind of thing and can give me any tips or advice? 25 years ago when we moved here I took down the wall between the lounge & dining room. Had to put in an RSJ. Did the calcs myself (pre internet days), got Building Control to approve. Took a weekend to do the job. Acro props are a must obviously. These days you can also hire Strong Boyshttp://www.knighton-tools.co.uk/acatalog/Masonry_Supports.html Biggest problem was cutting away the brickwork after installing the RSJ, used a mains angle grinder/cut off saw from a local hire shop. Dust simply unbelievable. Really. You cannot imagine it until you have done it. Panic buy dust masks! Also try taping off all doors etc. We found dust in unexpected areas for about 2 months afterwards. Slight difference in floor levels when the wall was cut away, be prepared for that. Still there 25 years later. Well within the capacity of a DIY guy, does need two of you at least. 5 years ago SWMBO decided a through lounge was a bad idea, so I put up a stud partition :-) -- Dave - The Medway Handymanwww.medwayhandyman.co.uk 01634 717930 07850 597257 Thanks for your advice. The sledgehammers will start swinging next Friday. I have the UB on order. It weighs nearly 200kg but hopefully with three of us we'll be able to slip the little blighter into place! We have dust masks for cutting the brickwork and will be sealing all doors....... You can pull back the carpets etc and get someone to wet the walls with a fine spray from a hose to reduce dust. Not as messy as you think if well directed, but be careful with electrical cutters. Simon. |
#6
Posted to uk.d-i-y
|
|||
|
|||
Knocking down a load bearing wall
On 1 Dec, 11:31, sm_jamieson wrote:
On 1 Dec, 09:33, Pete L wrote: On 13 Nov, 23:27, "The Medway Handyman" wrote: Pete L wrote: We want to knock down the wall between kitchen and dining room. Today the civil engineer man came round to inspect and give us the dimensions for the Universal Beam. He checked in the loft and the dividing wall is not supporting the roof - which is good. I've done plenty of diy jobs and we have done one house restoration but not knocking down a supporting wall.. I'd like to take on this job and have help available to place the UB. Question is - how difficult is it? Anybody out there done this kind of thing and can give me any tips or advice? 25 years ago when we moved here I took down the wall between the lounge & dining room. Had to put in an RSJ. Did the calcs myself (pre internet days), got Building Control to approve. Took a weekend to do the job. Acro props are a must obviously. These days you can also hire Strong Boyshttp://www.knighton-tools.co.uk/acatalog/Masonry_Supports.html Biggest problem was cutting away the brickwork after installing the RSJ, used a mains angle grinder/cut off saw from a local hire shop. Dust simply unbelievable. Really. You cannot imagine it until you have done it. Panic buy dust masks! Also try taping off all doors etc. We found dust in unexpected areas for about 2 months afterwards. Slight difference in floor levels when the wall was cut away, be prepared for that. Still there 25 years later. Well within the capacity of a DIY guy, does need two of you at least. 5 years ago SWMBO decided a through lounge was a bad idea, so I put up a stud partition :-) -- Dave - The Medway Handymanwww.medwayhandyman.co.uk 01634 717930 07850 597257 Thanks for your advice. The sledgehammers will start swinging next Friday. I have the UB on order. It weighs nearly 200kg but hopefully with three of us we'll be able to slip the little blighter into place! We have dust masks for cutting the brickwork and will be sealing all doors....... You can pull back the carpets etc and get someone to wet the walls with a fine spray from a hose to reduce dust. Not as messy as you think if well directed, but be careful with electrical cutters. Simon. Job done! Dust was, let's say, interesting...... The UB was ridiculously large but having spoken to the building inspector it's all due to the civil engineer covering himself against litigation. Apparently his calculation as to what size beam is required is 100% higher than is needed. His insurance company just want to make sure they never have to pay out! |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
This couldn't be a load bearing wall, could it? | Home Repair | |||
Knocking a load bearing wall | UK diy | |||
Knocking down non load bearing wall | UK diy | |||
load bearing wall | Home Repair | |||
load bearing wall | Home Repair |