UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 8
Default Honeywell acuator wiring - old to new

First thing to make clear is am not an electrician or plumber. I would
really appreciate the advice being non-technical.

I have a central heating system with 2 Honeywell V4043H1C56 actuators.

The hot water one (nearest the immersion) is working fine but the
other which controls the hot water going to the rads sticks &
therefore needs to be replaced.

First thing to make clear is that it is old & therefore I am having to
replace the actuator & install the converter plate as it is not the
more recent all in one model. Therefore I do have to drain the system.

Problem & therefore advice I need concerns the wiring. The currently
fitted old model has 5 wires, the new model has 6, the most
noticeable difference being an extra white wire.

Wiring in the cupboard is as follows - Colour at the start of each
line is the one from the current actuator

1. Blue & a 2nd blue feeds into to wiring block with a Blue, Blue &
Black on the other side of the wiring block.

2. Grey & a 2nd grey feeds into a Blue & Brown on the other side

3. Green with yellow stripe & a 2nd Green with yellow stripe feeds
into 2 Green with yellow stripes on the other side

4.Red & a 2nd Red feeds into a Red on the other side

5.Black is joined together with one yellow wire


This leaves two questions for installation of the new actuator-----

Do I use the brown wire on the new actuator in the same way as the
black in the previous & what do I do with the white wire in the new
actuator ?

Many thanks for anyone who can give me help.

Neil

  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2
Default Honeywell acuator wiring - old to new

On Fri, 10 Aug 2007 07:48:26 -0700, in uk.d-i-y Neil DG
wrote:

First thing to make clear is am not an electrician or plumber. I would
really appreciate the advice being non-technical.

I have a central heating system with 2 Honeywell V4043H1C56 actuators.

The hot water one (nearest the immersion) is working fine but the
other which controls the hot water going to the rads sticks &
therefore needs to be replaced.

First thing to make clear is that it is old & therefore I am having to
replace the actuator & install the converter plate as it is not the
more recent all in one model. Therefore I do have to drain the system.


What do you mean by "the converter plate"?

Problem & therefore advice I need concerns the wiring. The currently
fitted old model has 5 wires, the new model has 6, the most
noticeable difference being an extra white wire.


You need to tell us ALL the differenced. The new presumably has an
orange, yes?

Wiring in the cupboard is as follows - Colour at the start of each
line is the one from the current actuator

1. Blue & a 2nd blue feeds into to wiring block with a Blue, Blue &
Black on the other side of the wiring block.

2. Grey & a 2nd grey feeds into a Blue & Brown on the other side

3. Green with yellow stripe & a 2nd Green with yellow stripe feeds
into 2 Green with yellow stripes on the other side

4.Red & a 2nd Red feeds into a Red on the other side

5.Black is joined together with one yellow wire


This leaves two questions for installation of the new actuator-----


Do I use the brown wire on the new actuator in the same way as the
black in the previous & what do I do with the white wire in the new
actuator ?


NO!!! Some years ago red and black were used for live and neutral
respectively, but are nowadays replaced by brown and blue. i.e. red
replaced by brown, black replaced by blue.

Your description is not clear enough to give real advice, but

The Honeywell site has relevent info at
http://content.honeywell.com/uk/homes/FAQ/2port.pdf

It says the white is only fitted to 28mm an 1" valves AND replacement
heads part no. 40003916-001, so you can leave it unconnected (but
insulated).

The FAQ has more details at
http://www.diyfaq.org.uk/plumbing/co.../controls.html

Phil
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Installation of Honeywell RTH8500 thermostat - Wiring [email protected] Home Repair 21 July 30th 07 03:43 PM
Need Help Wiring Honeywell RTH7500 carpathia Home Repair 3 October 23rd 06 02:26 AM
Wiring a Honeywell RTH7500 Norwalk Paul Home Repair 2 October 23rd 05 08:22 PM
Honeywell Programmer wiring diagram Alan UK diy 6 November 2nd 04 11:35 AM
Leaving a Honeywell CH valve energised, wiring choices Toby UK diy 1 July 14th 03 06:20 PM


All times are GMT +1. The time now is 05:26 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"