Default Combi boiler - hot water isn't very hot, but radiators work OK

my Ravenheat Combi boiler had a problem recently where it was on zero
pressure, so I turned a plastic tap underneath which was connected to
a felxible pipe, which seemed to let more water into the boiler.

The radiators now all work full heat, but the hot water isn't very
hot, and the hot water isn't hot at all when the switch is switched
from central heating and hot water to just hot water. I've tried
varying settings on both thermostats.

It seems like something's wrong as the boiler used to be fine to pump
out hot water when the switch is just set to hot water.

Pressure is about 0.8 bar cold and i'm not sure what it is when hot
but its over 1 bar.

Has anyone got any ideas please before I call out a plumber?

Many thanks.

  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,231
Default Combi boiler - hot water isn't very hot, but radiators work OK

On Wed, 04 Apr 2007 01:19:10 -0700, iceland_potter wrote:

my Ravenheat Combi boiler had a problem recently where it was on zero
pressure, so I turned a plastic tap underneath which was connected to
a felxible pipe, which seemed to let more water into the boiler.

The radiators now all work full heat, but the hot water isn't very
hot, and the hot water isn't hot at all when the switch is switched
from central heating and hot water to just hot water. I've tried
varying settings on both thermostats.

It seems like something's wrong as the boiler used to be fine to pump
out hot water when the switch is just set to hot water.

Pressure is about 0.8 bar cold and i'm not sure what it is when hot
but its over 1 bar.

Has anyone got any ideas please before I call out a plumber?

Many thanks.


It's very likely the diverter valve. Switch the CH off, run a hW tap,
if the boiler fires and the CH flow pipe gets hot the that's really all
the proof you need.


--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html
Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 113
Default Combi boiler - hot water isn't very hot, but radiators work OK

On 4 Apr 2007 01:19:10 -0700, "iceland_potter"
wrote:

my Ravenheat Combi boiler had a problem recently where it was on zero
pressure, so I turned a plastic tap underneath which was connected to
a felxible pipe, which seemed to let more water into the boiler.

The radiators now all work full heat, but the hot water isn't very
hot, and the hot water isn't hot at all when the switch is switched
from central heating and hot water to just hot water. I've tried
varying settings on both thermostats.

It seems like something's wrong as the boiler used to be fine to pump
out hot water when the switch is just set to hot water.

Pressure is about 0.8 bar cold and i'm not sure what it is when hot
but its over 1 bar.

Has anyone got any ideas please before I call out a plumber?

Many thanks.



On the assumption that this is not a troll.....The plastic tap you
refer to is the control for the Filling Loop to increase the pressure
in the boiler .The instructions that were left by the installer ( They
were weren't they?) will explain all ( You have read them haven't you
??) .

AIUI the pressure should be read when cold and not hot so it might be
that you need to put more water in when it's cold .

Is there not a temp control for the HW so you can increase it to a
temp that suits you ?


  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 4
Default Combi boiler - hot water isn't very hot, but radiators work OK

Thanks Ed and Stuart,

Ed - sounds like it could be that, although when I turn the hot tap
on, there is immediately a burst of hot water, then it goes lukewarm
at best for sustained periods of time.

Stuart - Why would I be a troll? I have a problem with my boiler, so
I posted to a diy usenet group, please explain why you think I may
have been a troll?

I have put more water in the boiler from cold though to raise the
pressure to 1.2 bar, this seemed to work for a bit then after a day or
so I'm left with the lukewarm-at-best problem as described.

  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,231
Default Combi boiler - hot water isn't very hot, but radiators work OK

On Tue, 10 Apr 2007 01:35:16 -0700, iceland_potter wrote:

Thanks Ed and Stuart,

Ed - sounds like it could be that, although when I turn the hot tap
on, there is immediately a burst of hot water, then it goes lukewarm
at best for sustained periods of time.

Stuart - Why would I be a troll? I have a problem with my boiler, so
I posted to a diy usenet group, please explain why you think I may
have been a troll?

I have put more water in the boiler from cold though to raise the
pressure to 1.2 bar, this seemed to work for a bit then after a day or
so I'm left with the lukewarm-at-best problem as described.


The most likely failure modes a

1) The water flow diaphragm has partly split is becoming less sensistive
and effective, whilst it still switches the boiler on it is not strong
enough to move the valve fully to the DHW position.

2) Due to anyone of a number of problems the diverter valve is too stiff
to shift to the DHW position.

HTH

--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html
Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards


  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 4
Default Combi boiler - hot water isn't very hot, but radiators work OK

Thanks Ed,

I ended up getting a gas boiler firm out under a caveat of my home
insurance who took a look. After much tutting he decided a whole
diverter valve replacement was required. He's due to come tomorrow,
lets hope this sorts out my boiler.

  #7   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 4
Default Combi boiler - hot water isn't very hot, but radiators work OK

Just for completeness, thought i'd post. The diverter valve was
replaced and boiler sorted.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Radiators only work when Hot Water is on. Organoman UK diy 11 April 5th 06 10:41 PM
Combi-boiler - No Hot Water unless CH is on. Terry UK diy 4 April 4th 06 12:16 AM
[Britony Combi boiler] Radiators don't get hot [email protected] UK diy 2 October 24th 05 06:16 PM
Combi boiler - Hot water 'heat dump' too hot Phil Addison UK diy 59 November 24th 04 07:33 PM
Boiler problem - hot water, cold radiators Dan the man UK diy 9 October 7th 03 11:26 PM


All times are GMT +1. The time now is 08:06 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"