Combi boiler external controls help
Looking to fit an external controller for my recently fitted boiler, but am
a little confused as to which one to use/choose. They seem to be categorised into "programmers", "timeswitches", and even "mini programmers" (according to http://www.discountedheating.co.uk), but some apear to belong to more than one category. Could someone please care to explain the difference? BTW, I am looking for one that can do 5/2 or 7 day, 1 hour override, holiday mode, single channel, 3 on/off per day. I have a 3 c+e 2.5mm cable running from the boiler to the position where the controller is to be fitted. Many thanks in advance. |
#2
Posted to uk.d-i-y
|
|||
|
|||
Combi boiler external controls help
JoeJoe wrote:
Looking to fit an external controller for my recently fitted boiler, but am a little confused as to which one to use/choose. They seem to be categorised into "programmers", "timeswitches", and even "mini programmers" (according to http://www.discountedheating.co.uk), but some apear to belong to more than one category. Could someone please care to explain the difference? BTW, I am looking for one that can do 5/2 or 7 day, 1 hour override, holiday mode, single channel, 3 on/off per day. I have a 3 c+e 2.5mm cable running from the boiler to the position where the controller is to be fitted. You may find that a programmable room stat is a simpler solution. Something like: http://www.screwfix.com/app/sfd/cat/...12157&ts=17856 You cease needing to worry about on/off cycles etc and just tell it the temperature you want at various times during day. -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |
#3
Posted to uk.d-i-y
|
|||
|
|||
Combi boiler external controls help
"John Rumm" wrote in message ... JoeJoe wrote: Looking to fit an external controller for my recently fitted boiler, but am a little confused as to which one to use/choose. They seem to be categorised into "programmers", "timeswitches", and even "mini programmers" (according to http://www.discountedheating.co.uk), but some apear to belong to more than one category. Could someone please care to explain the difference? BTW, I am looking for one that can do 5/2 or 7 day, 1 hour override, holiday mode, single channel, 3 on/off per day. I have a 3 c+e 2.5mm cable running from the boiler to the position where the controller is to be fitted. You may find that a programmable room stat is a simpler solution. Something like: http://www.screwfix.com/app/sfd/cat/...12157&ts=17856 You cease needing to worry about on/off cycles etc and just tell it the temperature you want at various times during day. Thanks for that. However, it is a pretty big house, and I don't want to have to have to rely on one central thermostat. Each radiator has its own TRV, so I just want to be able to control On and Off times. |
#4
Posted to uk.d-i-y
|
|||
|
|||
Combi boiler external controls help
Thanks for that. However, it is a pretty big house, and I don't want to
have to have to rely on one central thermostat. Each radiator has its own TRV, so I just want to be able to control On and Off times. What are you using for the boiler interlock? Do you have one room with a room thermostat? Do you have a flow switch instead? Some other method? I presume you haven't subzoned? Christian. |
#5
Posted to uk.d-i-y
|
|||
|
|||
Combi boiler external controls help
In article ,
JoeJoe wrote: Could someone please care to explain the difference? BTW, I am looking for one that can do 5/2 or 7 day, 1 hour override, holiday mode, single channel, 3 on/off per day. I have a 3 c+e 2.5mm cable running from the boiler to the position where the controller is to be fitted. 2.5mm? Never seen that in triple and earth. 1mm should be fine. My choice would be the Horstmann H17XL. -- *Those who live by the sword get shot by those who don't* Dave Plowman London SW To e-mail, change noise into sound. |
#6
Posted to uk.d-i-y
|
|||
|
|||
Combi boiler external controls help
JoeJoe wrote:
You cease needing to worry about on/off cycles etc and just tell it the temperature you want at various times during day. Thanks for that. However, it is a pretty big house, and I don't want to have to have to rely on one central thermostat. Each radiator has its own TRV, so I just want to be able to control On and Off times. Well it does that as well, and the TRVs can still do their stuff. It does provide a boiler interlock (i.e. turns it off when the house is up to temperature (and the boiler would otherwise be trying to force water through a bunch of mostly closed TRVs) -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |
#7
Posted to uk.d-i-y
|
|||
|
|||
Combi boiler external controls help
On Wed, 04 Oct 2006 00:27:43 +0100, John Rumm wrote:
JoeJoe wrote: Looking to fit an external controller for my recently fitted boiler, but am a little confused as to which one to use/choose. They seem to be categorised into "programmers", "timeswitches", and even "mini programmers" (according to http://www.discountedheating.co.uk), but some apear to belong to more than one category. Could someone please care to explain the difference? BTW, I am looking for one that can do 5/2 or 7 day, 1 hour override, holiday mode, single channel, 3 on/off per day. I have a 3 c+e 2.5mm cable running from the boiler to the position where the controller is to be fitted. You may find that a programmable room stat is a simpler solution. Something like: http://www.screwfix.com/app/sfd/cat/...12157&ts=17856 You cease needing to worry about on/off cycles etc and just tell it the temperature you want at various times during day. Agreed this control (I've fitted around 50 units) does exactly what you want. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at http://www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards |
#8
Posted to uk.d-i-y
|
|||
|
|||
Combi boiler external controls help
"Dave Plowman (News)" wrote in message ... In article , JoeJoe wrote: Could someone please care to explain the difference? BTW, I am looking for one that can do 5/2 or 7 day, 1 hour override, holiday mode, single channel, 3 on/off per day. I have a 3 c+e 2.5mm cable running from the boiler to the position where the controller is to be fitted. 2.5mm? Never seen that in triple and earth. 1mm should be fine. My choice would be the Horstmann H17XL. Thanks for that - just ordered one. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Indirect Pandora Heatbank and Man Micromat/Boiler compatability | UK diy | |||
Combi boiler with underfloor heating? | UK diy | |||
New condensing boiler installation - truth or lies | UK diy | |||
Condensing Boiler News | UK diy | |||
new combi experience report | UK diy |