Hi,
Have a friend with a brand new Baxi Platinum 24HE "System Boiler", and I need a new Combi boiler. They look identical, and the only difference we can see is the diverter valve. In the Combi it should have a 'T' and in his System one it just goes out to one outlet, to connect to a cylinder. Is it just a matter of replacing that with a T from their Combi model, does anyone know, or are there more complicated things to worry about? -- Thanks, Me Try Google Quik-e-search™ at www.Superhighstreet.com/home ....Finds anything or they buy it for you! |
#2
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() "Chris Tomlinson" wrote in message .uk... Hi, Have a friend with a brand new Baxi Platinum 24HE "System Boiler", and I need a new Combi boiler. They look identical, and the only difference we can see is the diverter valve. In the Combi it should have a 'T' and in his System one it just goes out to one outlet, to connect to a cylinder. Is it just a matter of replacing that with a T from their Combi model, does anyone know, or are there more complicated things to worry about? There is temperature control as well. If you want to convert it to a combi. Buy a plate heat exchanger, a flow switch, blending valve and an electric 3-way "diverting" valve. Have the flowswitch on the cold mains to the plate, when activated. it fires the boiler and diverts the 3-way valve to send all the boilers flow to the plate. All the boilers output will go through the plate heat exchanger. The blending valve will set the output temperature. If you can get some of the components inside the case fine. I think most would all be outside. Could be in the cupboard under the sink well insulated. |
#3
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() Chris Tomlinson wrote: Hi, Have a friend with a brand new Baxi Platinum 24HE "System Boiler", and I need a new Combi boiler. They look identical, and the only difference we can see is the diverter valve. In the Combi it should have a 'T' and in his System one it just goes out to one outlet, to connect to a cylinder. Is it just a matter of replacing that with a T from their Combi model, does anyone know, or are there more complicated things to worry about? -- Thanks, Me You need a http://www.heatweb.com/products/boilermaster/boilermaster.htm It's a heat exchanger with associated stuff that goes with a system boiler and effectively makes it a combi. A |
#4
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() wrote in message oups.com... Chris Tomlinson wrote: Hi, Have a friend with a brand new Baxi Platinum 24HE "System Boiler", and I need a new Combi boiler. They look identical, and the only difference we can see is the diverter valve. In the Combi it should have a 'T' and in his System one it just goes out to one outlet, to connect to a cylinder. Is it just a matter of replacing that with a T from their Combi model, does anyone know, or are there more complicated things to worry about? -- Thanks, Me You need a http://www.heatweb.com/products/boilermaster/boilermaster.htm It's a heat exchanger with associated stuff that goes with a system boiler and effectively makes it a combi. Buying the parts separately is much cheaper. Using this box, you can fit a large, say 50kW boiler and it will deliver amazing flowrates. |
#5
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() wrote in message ... On 31 Jul, wrote: You need a http://www.heatweb.com/products/boilermaster/boilermaster.htm It's a heat exchanger with associated stuff that goes with a system boiler and effectively makes it a combi. That and their shower master look interesting. No mention of prices on their site, which probably means they are expensive. I couldn't find an alternative source using google. They are special made to order. |
#6
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() wrote in message oups.com... Chris Tomlinson wrote: Hi, Have a friend with a brand new Baxi Platinum 24HE "System Boiler", and I need a new Combi boiler. They look identical, and the only difference we can see is the diverter valve. In the Combi it should have a 'T' and in his System one it just goes out to one outlet, to connect to a cylinder. Is it just a matter of replacing that with a T from their Combi model, does anyone know, or are there more complicated things to worry about? -- Thanks, Me You need a http://www.heatweb.com/products/boilermaster/boilermaster.htm It's a heat exchanger with associated stuff that goes with a system boiler and effectively makes it a combi. That is the wrong box: "Ideal for use on district heating and central boiler applications." This convertes a normal boioer to give instant hot water: http://www.heatweb.com/products/showermaster/showermaster.htm |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Indirect Pandora Heatbank and Man Micromat/Boiler compatability | UK diy | |||
New condensing boiler installation - truth or lies | UK diy | |||
Baxi Boiler | UK diy | |||
11degC across Boiler, why? | UK diy | |||
Baxi Solo 2 PF 80 boiler won't fire up | UK diy |