#1
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
http://www.clubi.ie/plumbing-heating/bm.htm
Some may have seen this before - and of course it's not restricted to the Irish, I've seen stuff like this in the UK often enough. -- Skipweasel Pay no attention to the man behind the curtain. |
#2
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
On Sun, 12 Mar 2006 22:35:57 GMT, Guy King
wrote: http://www.clubi.ie/plumbing-heating/bm.htm Some may have seen this before - and of course it's not restricted to the Irish, I've dealt with Irish (Northern) plumbers and have _never_ met such a cack-handed bunch of bodge merchants in my life. Except perhaps my sister-in-law's plasterers, who managed to burn the cavity wall insulation out - by lighting a fire to keep warm, before the fireplace hearth was installed or the flue properly lined. We got off lightly, with merely the toilet cistern overflow that disappeared into an internal wall, the bath that had to be bailed through the window to empty it (and was self-filling in heavy rain) and of course the infamous Night of the Zombie Septic Tank. IMHE, it's down to the blatant nepotism that's rife in NI. "Ach, wee Jimmy will see you right" usually means "My idiot nephew Jimmy needs the work, as he's an inbred halfwit with vestigial gills. However we all drink at the same rugby club, and it's not either of us who has to live there afterwards". Oh, and they're not a patch on landfill contractors who turned our garden into an asbestos waste tip. Still, there was a drink in it for the right people, so that's alright then. |
#3
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
Andy Dingley wrote: Guy King wrote: http://www.clubi.ie/plumbing-heating/bm.htm Some may have seen this before - and of course it's not restricted to the Irish, I've dealt with Irish (Northern) plumbers and have _never_ met such a cack-handed bunch of bodge merchants in my life. RACIST !!!! Well, if the Jews and pikeys are getting some air cover ... ;-) P. |
#4
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
On Sun, 12 Mar 2006 22:35:57 +0000, Guy King wrote:
http://www.clubi.ie/plumbing-heating/bm.htm Some may have seen this before - and of course it's not restricted to the Irish, I've seen stuff like this in the UK often enough. The "Cistern overflow pipe and vent over flue" also shows the flue being unacceptably close to an air vent. Overall interesting, but sad that the text is as shoddy in places as the work it illustrates. |
#5
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
In message , John Stumbles
writes On Sun, 12 Mar 2006 22:35:57 +0000, Guy King wrote: http://www.clubi.ie/plumbing-heating/bm.htm Some may have seen this before - and of course it's not restricted to the Irish, I've seen stuff like this in the UK often enough. The "Cistern overflow pipe and vent over flue" also shows the flue being unacceptably close to an air vent. Overall interesting, but sad that the text is as shoddy in places as the work it illustrates. I wonder what Jewish plumbing's like -- geoff |
#6
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
"raden" wrote in message ... In message , John Stumbles writes On Sun, 12 Mar 2006 22:35:57 +0000, Guy King wrote: http://www.clubi.ie/plumbing-heating/bm.htm Some may have seen this before - and of course it's not restricted to the Irish, I've seen stuff like this in the UK often enough. The "Cistern overflow pipe and vent over flue" also shows the flue being unacceptably close to an air vent. Overall interesting, but sad that the text is as shoddy in places as the work it illustrates. I wonder what Jewish plumbing's like The same, but it says that way for longer as they are into their 20th estimate. |
#7
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
On Sun, 12 Mar 2006 22:35:57 GMT, Guy King
wrote: http://www.clubi.ie/plumbing-heating/bm.htm Some may have seen this before - and of course it's not restricted to the Irish, I've seen stuff like this in the UK often enough. The page http://www.clubi.ie/plumbing-heating/gripes.htm states:- "PTFE joint tape in the thread of compression fittings is a common sign of uninformed DIY." Where exactly is one supposed to put PTFE tape if not on the thread of compression fittings? -- Chris Cowley |
#8
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
The page http://www.clubi.ie/plumbing-heating/gripes.htm states:-
"PTFE joint tape in the thread of compression fittings is a common sign of uninformed DIY." Where exactly is one supposed to put PTFE tape if not on the thread of compression fittings? Well, certainly not on the thread of compression fittings. A compression joint works with a seal between the fitting and olive and between the olive and the pipe. These are metal to metal joints. Some people wrap the olive in PTFE, but this is unnecessary and could even cause leakages in the future if the PTFE degrades and there is no actual metal to metal seal. The thread on a compression joint is not part of the water seal and should not have PTFE applied. The sign of a professionally done compression joint is the use of no PTFE at all. PTFE is used on BSP fittings usually with a jointing compound. Examples are radiator tails and outside taps, where the thread IS part of the water seal. Christian. |
#9
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
On Mon, 13 Mar 2006 10:35:42 +0000, Christian McArdle wrote:
PTFE is used on BSP fittings usually with a jointing compound. Examples are radiator tails and outside taps, where the thread IS part of the water seal. You mean without, Shirley? PTFE tape OR jointing compound (e.g. Boss White) poss. with hemp. |
#10
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
PTFE is used on BSP fittings usually with a jointing compound. Examples
are radiator tails and outside taps, where the thread IS part of the water seal. You mean without, Shirley? PTFE tape OR jointing compound (e.g. Boss White) poss. with hemp. Nah, with. I smother the PTFE in Fernox LS-X. Works every time. Never once a leak, even on parallel BSP. I see PTFE as the hemp replacement and LS-X as the Boss White replacement. Christian. |
#11
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
On Mon, 13 Mar 2006 10:35:42 -0000, "Christian McArdle"
wrote: Where exactly is one supposed to put PTFE tape if not on the thread of compression fittings? Well, certainly not on the thread of compression fittings. A compression joint works with a seal between the fitting and olive and between the olive and the pipe. These are metal to metal joints. [snip] Oh right. I never knew - I've always used PTFE on compression threads as lots of sources seem to say it should be used (e.g. various DIY books, http://www.diydata.com/techniques/pl...ompression.htm ). I guess I can save myself a few pennies by stopping using it, then! Cheers, -- Chris Cowley |
#12
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
On Mon, 13 Mar 2006 15:44:41 +0000, Chris Cowley
wrote: Oh right. I never knew - I've always used PTFE on compression threads as lots of sources seem to say it should be used (e.g. various DIY books, http://www.diydata.com/techniques/pl...ompression.htm ). I guess I can save myself a few pennies by stopping using it, then! I always use it: 1. It ensures the thread doesn't seize and the joint can be tightened/dismantled easily at a later date. 2. It seals the thread. This can prevent a leak should any water find it's way between the outside of the olive and the main body of the joint. I agree that in theory a compression joint should be perfectly machined but in a lot of cases they aren't. sponix |
#13
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
The message
from Chris Cowley contains these words: Where exactly is one supposed to put PTFE tape if not on the thread of compression fittings? Well, I've never used it on compresion fittings - I've always used it on taper-threaded iron fittings. -- Skipweasel Pay no attention to the man behind the curtain. |
#14
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
Guy King wrote: Chris Cowley csaid Where exactly is one supposed to put PTFE tape if not on the thread of compression fittings? Well, I've never used it on compresion fittings - I've always used it on taper-threaded iron fittings. Or on BSP female tees with parallel threads, again for iron elbows etc. Wall plate elbows ... Spotting a pattern here, where the thread is involved in the seal. P. |
#15
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
Chris Cowley wrote:
The page http://www.clubi.ie/plumbing-heating/gripes.htm states:- "PTFE joint tape in the thread of compression fittings is a common sign of uninformed DIY." Where exactly is one supposed to put PTFE tape if not on the thread of compression fittings? Its real purpose is when you have to make a joint that requires a seal to be made on the threaded part of a connection. A compression fitting makes a seal between the pipe and casing by use of the olive - the threaded part itself does not even come into contact with the water. (In spite of it not being required, I personally still like a couple of turns on the thread of compression fittings since it lubricates the joint a little making it easier to do up tight, and disassemble later if required). -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |
#16
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
On Mon, 13 Mar 2006 10:49:23 +0000, John Rumm
wrote: Chris Cowley wrote: The page http://www.clubi.ie/plumbing-heating/gripes.htm states:- "PTFE joint tape in the thread of compression fittings is a common sign of uninformed DIY." Where exactly is one supposed to put PTFE tape if not on the thread of compression fittings? Its real purpose is when you have to make a joint that requires a seal to be made on the threaded part of a connection. A compression fitting makes a seal between the pipe and casing by use of the olive - the threaded part itself does not even come into contact with the water. ...in Theory. Of the olive seat/olive is less than perfect then water can seep past. sponix |
#17
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
"Sponix" wrote in message ... On Mon, 13 Mar 2006 10:49:23 +0000, John Rumm wrote: Chris Cowley wrote: The page http://www.clubi.ie/plumbing-heating/gripes.htm states:- "PTFE joint tape in the thread of compression fittings is a common sign of uninformed DIY." Where exactly is one supposed to put PTFE tape if not on the thread of compression fittings? Its real purpose is when you have to make a joint that requires a seal to be made on the threaded part of a connection. A compression fitting makes a seal between the pipe and casing by use of the olive - the threaded part itself does not even come into contact with the water. ..in Theory. In practice as well. Of the olive seat/olive is less than perfect then water can seep past. The water will work its way out via the gap between the nut and pipe. Look at a fitting. take it apart. |
#18
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
Chris Cowley wrote:
The page http://www.clubi.ie/plumbing-heating/gripes.htm states:- "PTFE joint tape in the thread of compression fittings is a common sign of uninformed DIY." Where exactly is one supposed to put PTFE tape if not on the thread of compression fittings? Things such as radiator tails. Taper threads. Gland packing, possibly. Not in compression fittings. |
#19
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
"Chris Bacon" wrote in message ... Chris Cowley wrote: The page http://www.clubi.ie/plumbing-heating/gripes.htm states:- "PTFE joint tape in the thread of compression fittings is a common sign of uninformed DIY." Where exactly is one supposed to put PTFE tape if not on the thread of compression fittings? Not at all, unless using plastic pipe. Things such as radiator tails. Yes, on BSP taper threads Taper threads. Yes, on BSP taper threads Gland packing, No. Not in compression fittings. See above. |
#20
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
"Doctor Drivel" wrote in message reenews.net... "Chris Bacon" wrote in message ... Chris Cowley wrote: The page http://www.clubi.ie/plumbing-heating/gripes.htm states:- "PTFE joint tape in the thread of compression fittings is a common sign of uninformed DIY." Where exactly is one supposed to put PTFE tape if not on the thread of compression fittings? A bloke I know swears by putting PTFE around the olives before tightening the compression fitting. Seems to work. A bit of normal threadlock on the threads - as much to stop it seizing/binding as to stop water. The olive seal is what counts for stopping water, not the thread. a |
#21
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
On Wed, 15 Mar 2006 23:51:48 GMT, "al"
wrote: A bloke I know swears by putting PTFE around the olives before tightening the compression fitting. I know blokes who swear blind that Elvis works down the chipshop, but it doesn't mean they're right. |
#22
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
al wrote:
A bloke I know swears by putting PTFE around the olives before tightening the compression fitting. Seems to work. A bit of normal threadlock on the threads - as much to stop it seizing/binding as to stop water. The olive seal is what counts for stopping water, not the thread. Gease/oil on the threads might stop them binding (it works fine on car wheel nuts) but threadlock can only lead to trouble. |
#23
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
"al" wrote in message news "Doctor Drivel" wrote in message reenews.net... "Chris Bacon" wrote in message ... Chris Cowley wrote: The page http://www.clubi.ie/plumbing-heating/gripes.htm states:- "PTFE joint tape in the thread of compression fittings is a common sign of uninformed DIY." Where exactly is one supposed to put PTFE tape if not on the thread of compression fittings? A bloke I know swears by putting PTFE around the olives before tightening the compression fitting. Seems to work. But so does cleaning the pipes and olives and not using *anything* else (which I always do and have never had one leak). Why add something that isn't required on the basis it "seems to work" A bit of normal threadlock on the threads - as much to stop it seizing/binding as to stop water. The olive seal is what counts for stopping water, not the thread. True but why put anything on the threads, I have never had one bind or seize if you clean everything and add nothing. -- Bob Mannix (anti-spam is as easy as 1-2-3 - not) |
#24
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
"Guy King" wrote in message ... http://www.clubi.ie/plumbing-heating/bm.htm Some may have seen this before - and of course it's not restricted to the Irish, I've seen stuff like this in the UK often enough. I have nothing like that all in one place. How about in Poland? |
#25
Posted to uk.d-i-y
|
|||
|
|||
Irish plumbing
We were somewhere around Barstow, on the edge of the desert, when the
drugs began to take hold. I remember Guy King saying something like: http://www.clubi.ie/plumbing-heating/bm.htm Some may have seen this before - and of course it's not restricted to the Irish, I've seen stuff like this in the UK often enough. Indeed. I've seen crap work all over the British Isles. This bit rings very true... "A reasonable charge should be made for a detailed written estimate as it is often used as a basis for corrective work carried out by others." I've been caught out by *******s like that a couple of times. -- Dave |