Hi,

Electrics are supposed to be simple. but perhaps it's me who is
simple.

We have a light fitting in the kitchen with 4 halogen bulbs. It is
controlled by 2 switches in parallel - one normal and one dimmer. It's
been working fine - every so often a bulb goes, trips the RCD, gets
replaced, and all continues working.

This time when one blew, it tripped the RCD, I reset the RCD and now
the light doesn't work at all. All other lights on the circuit work
OK. I have tightened all the wiring in the switches, and also the
fitting. A multimeter across the two contacts in each bulb housing
shows there is 240V getting to each one when the switch is on. I have
replaced every bulb with brand new ones. But still no light.

I have no idea where to go from here - surely if power is getting to
the bulbs then there can't be a wiring issue? Having said that I don't
know if the fact there's 240V there means there's enough *power*
there. I also noted that when the switch is off there is still about
25V across the contacts, but have no idea if this is normal.

Any ideas gratefully received

regards
-Rob
  #2   Report Post  
The3rd Earl Of Derby
 
Posts: n/a
Default Lights stopped working - help!

Rob wrote:
Hi,

Electrics are supposed to be simple. but perhaps it's me who is
simple.

We have a light fitting in the kitchen with 4 halogen bulbs. It is
controlled by 2 switches in parallel - one normal and one dimmer. It's
been working fine - every so often a bulb goes, trips the RCD, gets
replaced, and all continues working.

This time when one blew, it tripped the RCD, I reset the RCD and now
the light doesn't work at all. All other lights on the circuit work
OK. I have tightened all the wiring in the switches, and also the
fitting. A multimeter across the two contacts in each bulb housing
shows there is 240V getting to each one when the switch is on. I have
replaced every bulb with brand new ones. But still no light.

I have no idea where to go from here - surely if power is getting to
the bulbs then there can't be a wiring issue? Having said that I don't
know if the fact there's 240V there means there's enough *power*
there. I also noted that when the switch is off there is still about
25V across the contacts, but have no idea if this is normal.

Any ideas gratefully received

regards
-Rob


Maybe the contacts on that particular fitting has aquired a carbon deposit
build up on it and if so this would in effect trip the RCD when a lamp is
replaced?
--
Sir Benjamin Middlethwaite


  #3   Report Post  
Andrew Gabriel
 
Posts: n/a
Default Lights stopped working - help!

In article ,
Rob writes:
Hi,

Electrics are supposed to be simple. but perhaps it's me who is
simple.

We have a light fitting in the kitchen with 4 halogen bulbs. It is
controlled by 2 switches in parallel - one normal and one dimmer. It's
been working fine - every so often a bulb goes, trips the RCD, gets
replaced, and all continues working.

This time when one blew, it tripped the RCD, I reset the RCD and now


I suspect you mean MCB?

the light doesn't work at all. All other lights on the circuit work
OK. I have tightened all the wiring in the switches, and also the
fitting. A multimeter across the two contacts in each bulb housing
shows there is 240V getting to each one when the switch is on. I have
replaced every bulb with brand new ones. But still no light.


Multi-meters are not good for measuring mains voltage. A tiny
capacitive leakage in a length of cable can result in mains
voltage readings, when there is in fact no connection at all.

I have no idea where to go from here - surely if power is getting to
the bulbs then there can't be a wiring issue? Having said that I don't
know if the fact there's 240V there means there's enough *power*
there. I also noted that when the switch is off there is still about
25V across the contacts, but have no idea if this is normal.


I suspect the lamp which failed arced across, drawing high current,
and blew the dimmer (after all, it tripped the MCB instantly, which
probably means it passed over 30A momentarily). It might have only
blown a fuse in the dimmer, but IME it is likely to have blown the
triac (the key semi-conductor component).

--
Andrew Gabriel
  #5   Report Post  
Lurch
 
Posts: n/a
Default Lights stopped working - help!

On or around Sat, 05 Nov 2005 16:16:48 GMT, Rob
mused:

I thought the MCB would have tripped before the dimmer had
a chance to blow, but there ya go.

It would appear it did, several times.
--
| Stuart @ SJW Electrical. Please Reply to group. |
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Luminglas stopped working Sam Goldwasser Electronics Repair 3 October 30th 04 09:03 PM
two lights in sequence glow dimly only if both have working bulbs - why? and how to fix fixhouse Home Repair 9 August 10th 04 10:11 PM
Bathroom lights - what's allowed/required? [email protected] UK diy 16 October 15th 03 11:26 PM
electric oven stopped working Haroon Electronics Repair 5 July 21st 03 04:42 AM


All times are GMT +1. The time now is 06:08 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"