I was servicing my Keston Celcius 25 yesterday.

Over the years, I have noticed slight rust staining on the
bottom of the inside of the cover along the metalwork seam.
Obviously some moisture is ending up there, but I never
found the source. The sealed system has lost no pressure
in 3 years, and when running a garden hose into the end of
the flue, there is no condensate leak. I leave the automatic
bleed valve closed, so it's not that. The amount of water
must be small as I have never seen any there, and the
staining does mostly just wipe off, and there's no sign
on the outside of the case/cover.

Anyway, I think I found the source. I was running the
boiler with the cover off. The boiler is hard up against
a wall on the right hand side, which is bare unpainted
plaster. The air intake pipe faces this wall. When the
run-on timer finishes and the fan stops, moisture laiden
air convects out of the air intake. I noticed this because
without the cover on, enough was coming out to make the
plaster wet and change to a dark colour. With the cover
on, this is going to condense on the inside of the cover
and run down to the bottom.

To prevent any long term problem with this eventually
corroding through the case, I have run a bead of
silicone seal around the inside corners of the cover
bottom where there is a metal seam. The metal surface
seems to be sufficiently protected by the painted enamel
finish. The moisture probably evaporates next time the
boiler runs for a while. This might be a useful tip for
other Keston owners here who service their own boilers.

--
Andrew Gabriel
  #2   Report Post  
fred
 
Posts: n/a
Default

In article , Andrew
Gabriel writes
I was servicing my Keston Celcius 25 yesterday.

Over the years, I have noticed slight rust staining on the
bottom of the inside of the cover along the metalwork seam.


Thanks Andy, I've not noticed this on mine but will keep a look out. I
wonder if it depends on the flue configuration, natural convection meaning
that some (mine) don't see this but others do. If it helps, mine has a short
neutrally ventilated inlet with a v long vertical outlet.
--
fred
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
More Keston Woes Richard UK diy 10 May 24th 06 08:36 PM
Keston problem and solution Andrew Gabriel UK diy 26 December 26th 04 05:48 PM
keston boiler problem Richard UK diy 5 August 12th 04 07:25 AM
Keston Questions (noise and flue options) Andrew UK diy 26 December 3rd 03 07:05 PM
Finding a gas fitter to install a Keston Celsius 25 - success!!! Tim Mitchell UK diy 0 September 16th 03 01:11 PM


All times are GMT +1. The time now is 12:31 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"