This leads to a pdf explaining the basic stuff:
https://electrical.nebraska.gov/sites/electrical.nebraska.gov/files/doc/FREQUENTLY%20ASKED%20FLOOD%20QUESTIONS%202019.pdf

Anything below the high water mark needs to be replaced. There
will be a lot
of really busy people over the next few months.
It seems odd that a homeowner can rewire his principal residence but
has to hire
a pro to wire a weekend home.
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 14,141
Default Electrical Inspections, Nebraska floods, FAQ

On Wed, 20 Mar 2019 17:05:48 -0500, Dean Hoffman
wrote:

This leads to a pdf explaining the basic stuff:
https://electrical.nebraska.gov/sites/electrical.nebraska.gov/files/doc/FREQUENTLY%20ASKED%20FLOOD%20QUESTIONS%202019.pdf

Anything below the high water mark needs to be replaced. There
will be a lot
of really busy people over the next few months.
It seems odd that a homeowner can rewire his principal residence but
has to hire
a pro to wire a weekend home.


Typically if your second home is never rented and you are not selling
it soon, you can still get an owner/builder permit.

BTW this is something most people do not think of

******************
7.
Water has been in my home how much electrical wiring has to
be replaced?
Electrical equipment and devices that were below the high flood water
line will need to be replaced. NM Cable will need to be replaced or
cut back to a point that the interior paper is dry.
***********************

All the more reason to consider using UF or THHN/THWN in a raceway if
flooding might be an issue. I used Smurf Tube and individual
conductors in my addition. It really did not add much to the final
cost and provided some great benefits.

http://gfretwell.com/electrical/addi...murf%20job.jpg
http://gfretwell.com/electrical/addition/J%20box.jpg
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,636
Default Electrical Inspections, Nebraska floods, FAQ

On 3/20/19 5:51 PM, wrote:
On Wed, 20 Mar 2019 17:05:48 -0500, Dean Hoffman
wrote:

This leads to a pdf explaining the basic stuff:
https://electrical.nebraska.gov/sites/electrical.nebraska.gov/files/doc/FREQUENTLY%20ASKED%20FLOOD%20QUESTIONS%202019.pdf

Anything below the high water mark needs to be replaced. There
will be a lot
of really busy people over the next few months.
It seems odd that a homeowner can rewire his principal residence but
has to hire
a pro to wire a weekend home.


Typically if your second home is never rented and you are not selling
it soon, you can still get an owner/builder permit.

BTW this is something most people do not think of

******************
7.
Water has been in my home how much electrical wiring has to
be replaced?
Electrical equipment and devices that were below the high flood water
line will need to be replaced. NM Cable will need to be replaced or
cut back to a point that the interior paper is dry.
***********************

All the more reason to consider using UF or THHN/THWN in a raceway if
flooding might be an issue. I used Smurf Tube and individual
conductors in my addition. It really did not add much to the final
cost and provided some great benefits.

http://gfretwell.com/electrical/addi...murf%20job.jpg
http://gfretwell.com/electrical/addition/J%20box.jpg

There isn't much space left in that box. The news people are
using the
words historic and unprecedented to describe the flooding. The Platte
River
runs across the state east to west and floods almost every year. It's wide
and shallow so freezes up. Ice jams cause the flooding. The name
Nebraska is based on an Oto Indian word meaning "flat water".
The flooding is mainly in the eastern third of the state. Frozen
ground, snow melt,
and a storm called a bomb cyclone made a lot of rivers overflow.
  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 14,141
Default Electrical Inspections, Nebraska floods, FAQ

On Wed, 20 Mar 2019 18:43:08 -0500, Dean Hoffman
wrote:

On 3/20/19 5:51 PM, wrote:
On Wed, 20 Mar 2019 17:05:48 -0500, Dean Hoffman
wrote:

This leads to a pdf explaining the basic stuff:
https://electrical.nebraska.gov/sites/electrical.nebraska.gov/files/doc/FREQUENTLY%20ASKED%20FLOOD%20QUESTIONS%202019.pdf

Anything below the high water mark needs to be replaced. There
will be a lot
of really busy people over the next few months.
It seems odd that a homeowner can rewire his principal residence but
has to hire
a pro to wire a weekend home.


Typically if your second home is never rented and you are not selling
it soon, you can still get an owner/builder permit.

BTW this is something most people do not think of

******************
7.
Water has been in my home how much electrical wiring has to
be replaced?
Electrical equipment and devices that were below the high flood water
line will need to be replaced. NM Cable will need to be replaced or
cut back to a point that the interior paper is dry.
***********************

All the more reason to consider using UF or THHN/THWN in a raceway if
flooding might be an issue. I used Smurf Tube and individual
conductors in my addition. It really did not add much to the final
cost and provided some great benefits.

http://gfretwell.com/electrical/addi...murf%20job.jpg
http://gfretwell.com/electrical/addition/J%20box.jpg

There isn't much space left in that box.


How do you figure that? It is a 256 CU/IN box (8x8x4) and I am nowhere
near the 113 12 ga conductors that would fit.
Since all grounds only count as one the conductor count is less than
20
The news people are
using the
words historic and unprecedented to describe the flooding. The Platte
River
runs across the state east to west and floods almost every year. It's wide
and shallow so freezes up. Ice jams cause the flooding. The name
Nebraska is based on an Oto Indian word meaning "flat water".
The flooding is mainly in the eastern third of the state. Frozen
ground, snow melt,
and a storm called a bomb cyclone made a lot of rivers overflow.


Yeah I saw that on the news, How many of these people are actually in
a designated flood zone? (FEMA)

  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,636
Default Electrical Inspections, Nebraska floods, FAQ

On 3/20/19 7:08 PM, wrote:
On Wed, 20 Mar 2019 18:43:08 -0500, Dean Hoffman
wrote:

On 3/20/19 5:51 PM,
wrote:
On Wed, 20 Mar 2019 17:05:48 -0500, Dean Hoffman
wrote:

This leads to a pdf explaining the basic stuff:
https://electrical.nebraska.gov/sites/electrical.nebraska.gov/files/doc/FREQUENTLY%20ASKED%20FLOOD%20QUESTIONS%202019.pdf

Anything below the high water mark needs to be replaced. There
will be a lot
of really busy people over the next few months.
It seems odd that a homeowner can rewire his principal residence but
has to hire
a pro to wire a weekend home.

Typically if your second home is never rented and you are not selling
it soon, you can still get an owner/builder permit.

BTW this is something most people do not think of

******************
7.
Water has been in my home how much electrical wiring has to
be replaced?
Electrical equipment and devices that were below the high flood water
line will need to be replaced. NM Cable will need to be replaced or
cut back to a point that the interior paper is dry.
***********************

All the more reason to consider using UF or THHN/THWN in a raceway if
flooding might be an issue. I used Smurf Tube and individual
conductors in my addition. It really did not add much to the final
cost and provided some great benefits.

http://gfretwell.com/electrical/addi...murf%20job.jpg
http://gfretwell.com/electrical/addition/J%20box.jpg

There isn't much space left in that box.


How do you figure that? It is a 256 CU/IN box (8x8x4) and I am nowhere
near the 113 12 ga conductors that would fit.
Since all grounds only count as one the conductor count is less than
20

Dummy attack on my part. I just looked at the 7 conduits and
2 cables
going in. I didn't realize how deep the box is.
The news people are
using the
words historic and unprecedented to describe the flooding. The Platte
River
runs across the state east to west and floods almost every year. It's wide
and shallow so freezes up. Ice jams cause the flooding. The name
Nebraska is based on an Oto Indian word meaning "flat water".
The flooding is mainly in the eastern third of the state. Frozen
ground, snow melt,
and a storm called a bomb cyclone made a lot of rivers overflow.


Yeah I saw that on the news, How many of these people are actually in
a designated flood zone? (FEMA)

No idea.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Electrical Inspections Chris B[_2_] UK diy 72 August 21st 17 10:32 PM
What training/qualifications/letters are needed to do caravan site electrical inspections/certificates? [email protected] UK diy 1 July 7th 11 12:07 AM
OT - Cowboys & the floods Don Spumey UK diy 48 July 10th 07 09:17 PM
Floods Of $10.00 Bills In Your Bank Account Today mahlbergs Home Ownership 0 September 27th 05 12:40 AM
Jet Lathe in Southeast Nebraska Matt Metalworking 1 August 26th 04 10:11 PM


All times are GMT +1. The time now is 03:49 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"