#41
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
replying to Pop Rivet, William Ross wrote:
Truly made offshore!~ -- for full context, visit https://www.homeownershub.com/mainte...it-538066-.htm |
#42
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
On Friday, December 29, 2017 at 4:14:06 PM UTC-6, William Ross wrote:
replying to Joshua, William Ross wrote: Looks like you bought an overseas appliance. This is why you need a transformer when American and traveling abroad. -- You're too late. 13 years ago, Joshua was abducted by giant outer space alien gerbils. The Air Force was unable to catch up with the flying saucer and Joshua has never been seen again. It's feared that the giant alien gerbils used him as a sex slave then ate him. It was a tragic loss. O_o [8~{} Uncle Alien Monster |
#43
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
On Friday, December 29, 2017 at 4:14:07 PM UTC-6, William Ross wrote:
replying to Pop Rivet, William Ross wrote: Truly made offshore!~ -- You're too late again. 13 years ago Pop Rivet was a victim of a hit carried out by the Renovators Gang. His lifeless body was found pop-rivetted to his pickup truck. Another tragic event. 8-( [8~{} Uncle Popped Monster |
#44
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
replying to TURTLE, Jr Frazier wrote:
I have a stratus aircond that goes in a electrial cab that came 480v 1 single plase. I was think two legs of 480 hot but just wont to check .hate to blow up 2500.00 dollar aircon -- for full context, visit https://www.homeownershub.com/mainte...it-538066-.htm |
#45
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
On Wed, 21 Feb 2018 20:14:03 GMT, Jr Frazier
m wrote: replying to TURTLE, Jr Frazier wrote: I have a stratus aircond that goes in a electrial cab that came 480v 1 single plase. I was think two legs of 480 hot but just wont to check .hate to blow up 2500.00 dollar aircon If it really says 480 1P then you do use two phase conductors of your 3P. If this was intended to be line to neutral it would be rated 277V, pretty popular in lighting. |
#46
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
I have a bowl feeder that we recieved from China that is single phase 480. The control unit has a black and white wire with a ground. It's not difficult to find 480 single phase on your transformer. In this case a header machine. If your transformer doesn't have a legible diagram, just find your single phase 480 by checking between the legs on the transformer. If it's fed by 480V 3ph you should be able to find it. I'm not an electrician, just an industrial maintenance guy, but I've had to do this many times as China doesn't wire their machines like American or European manufacturers.
|
#47
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
|
#49
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
On Wed, 1 May 2019 11:51:54 -0700 (PDT), TimR
wrote: On Wednesday, May 1, 2019 at 12:13:32 PM UTC-4, wrote: On Wed, 1 May 2019 08:16:39 -0700 (PDT), wrote: I have a bowl feeder that we recieved from China that is single phase 480. The control unit has a black and white wire with a ground. It's not difficult to find 480 single phase on your transformer. In this case a header machine. If your transformer doesn't have a legible diagram, just find your single phase 480 by checking between the legs on the transformer. If it's fed by 480V 3ph you should be able to find it. I'm not an electrician, just an industrial maintenance guy, but I've had to do this many times as China doesn't wire their machines like American or European manufacturers. On a 480/277 transformer you will be using 2 "hots". Typically they will be the Brown, Orange and Yellow legs. Gray will be the neutral. The 277 circuits will be Violet and Gray by the normal convention although it is not in the code. I don't know what a bowl feeder is but if it has a motor, and you connect to 3P power, it will run backwards. You need to unhook it and reverse the legs. All my time in a factory I never saw that not happen. It was so common in the computer biz newer machines had a reversing plug in the primary power tub that swapped 2 legs. If this is a single phase motor it doesn't really make any difference tho. You are only using 2 of the 3 phases. |
#50
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
On Wednesday, May 1, 2019 at 3:08:35 PM UTC-4, wrote:
On Wed, 1 May 2019 11:51:54 -0700 (PDT), TimR wrote: On Wednesday, May 1, 2019 at 12:13:32 PM UTC-4, wrote: On Wed, 1 May 2019 08:16:39 -0700 (PDT), wrote: I have a bowl feeder that we recieved from China that is single phase 480. The control unit has a black and white wire with a ground. It's not difficult to find 480 single phase on your transformer. In this case a header machine. If your transformer doesn't have a legible diagram, just find your single phase 480 by checking between the legs on the transformer. If it's fed by 480V 3ph you should be able to find it. I'm not an electrician, just an industrial maintenance guy, but I've had to do this many times as China doesn't wire their machines like American or European manufacturers. On a 480/277 transformer you will be using 2 "hots". Typically they will be the Brown, Orange and Yellow legs. Gray will be the neutral. The 277 circuits will be Violet and Gray by the normal convention although it is not in the code. I don't know what a bowl feeder is but if it has a motor, and you connect to 3P power, it will run backwards. You need to unhook it and reverse the legs. All my time in a factory I never saw that not happen. It was so common in the computer biz newer machines had a reversing plug in the primary power tub that swapped 2 legs. If this is a single phase motor it doesn't really make any difference tho. You are only using 2 of the 3 phases. Yeah I saw that but I wasn't sure I believed it was 1P. I can guarantee at least one motor that will run backwards on 1P though: my drill, if you're next to me and ask to borrow it. |
#51
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
Lol, i just wired some single phase 480v dope lights for a client.
|
#52
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
replying to Joshua, Justin Oliver wrote:
You have a 3 phase service.not a 3 pole service but it is the same.your just using 2 of your poles. The correct way to say that is 2 legs of the 3 phases or poles. Two legs or poles is single phase when using equipment. -- for full context, visit https://www.homeownershub.com/mainte...it-538066-.htm |
#53
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
replying to gfretwell, Justin Oliver wrote:
Thay get the 3 phase motor going by raping a rope around the shaft and pulling before starting or using a capacitor on a phase to make another phase then drop that phase after full speed then dropping that phase. And at that phase you dropped you will be getting 277 90 degree off of power companys sistem. You can use that as another phase to make a 3 phase sistem -- for full context, visit https://www.homeownershub.com/mainte...it-538066-.htm |
#54
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
replying to TURTLE, Justin Oliver wrote:
It is probably a277 or a 480 volt single phase motor You can probably wire those HVAC fan motor different ways. -- for full context, visit https://www.homeownershub.com/mainte...it-538066-.htm |
#55
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
That's a great question and I'm glad you asked and paid enough attention to realize that it was single phase rather than terminating it 3 phase.for Single phase 480v just land the 2 hits and a ground. There is no such thing as a stupid question my friends
|
#56
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
|
#57
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
If I have a 240/480 volt dual voltage single phase motor connected by 2.5mm 2c+e to an isolator and then just 1mm flex coming out with active, neutral and earth connected is it possible the power supply to be 480v or is it most definitely 240v
|
#58
Posted to alt.home.repair
|
|||
|
|||
Wiring a 480V Single Phase Circuit
On May 15, 2020 12:40PM, wrote in alt.home.repair:
That's a great question and I'm glad you asked and paid enough attention to realize that it was single phase rather than terminating it 3 phase.for Single phase 480v just land the 2 hits and a ground. There is no such thing as a stupid question my friends. I assume you mean 2 "hots" which would be different phases (not hits) and then a third wire being a green ground connection (a total of three wires. 2 hots of the same phase would be like wiring-up switching devices where one wire is line and the other is load. |