We own a 5000/6260 Watt generator that is used for temporary emergency
service during electrical outages. In our area (SE Kansas). Outages
related to thunderstorms and ice storms are fairly common. Outages
can last from a couple of hours to more than a day.

Being a lot Irish, I really don't want to spring for the full $600 -
$1,000+ plus for a full up transfer switch installation. A am also
opposed to the old Dryer Plug approach. Remembering to isolate the
house with main breakers might work now; but as our brains age it
looks like a good way to kill a lineman. Here are needs and a
proposed approach:

Main Needs a
1) Sump Pump main control circuit (basement)
2) Backup Sump Pump battery charger circuit (basement)
3) Furnace (central heat NOT air conditioning - basement)
4) Freezer (basement)
5) Refrigerator (main floor)

These five items are well within normal and surge capacity of the
generator so I should have some capacity to run a few lamps.

Planned Approach:

1) Install a standard four prong female generator connection box so
that 10/4 wire passes directly through the sill plate of the house.
This will be done outside, or just inside of the garage door. (In
either case the generator will, of course, be located well away from
the house).

2) The 10/4 wire, from the box, will enter the basement and be routed
down to about four feet above the floor via conduit.

3) At the bottom of the wire/conduit I will install a fourplex box and
split the circuit into two 120v circuits with a standard two-plug
receptacle on each. This will serve items 1) through 4) above via
direct connection or extension cords. The longest cord run will be
15-20'

This circuit will be "dumb" and will not be hooked to the main house
circuit.

When needed, we will move the generator outside of the garage and use
a standard 4-blade, 30 amp, 30' generator cord to connect the
generator to the dumb circuit which will serve basement needs. The
fridge and lights will be served by a couple of the four standard 120v
circuits on the generator.

Anyone else done something similar - or better? I do want to keep
cost down and keep it safe. But it is a solution that MIGHT get used
once every year or so.

Thanks
RonB
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
generator capable of emergency power to small freezer as well as tools on the allotment etc Allthumbs UK diy 12 July 22nd 09 01:10 PM
Emergency power system for one perosn: Generator or battery system? [email protected] Home Repair 89 February 18th 09 12:19 PM
exercising an emergency generator Jim Elbrecht Home Repair 47 December 21st 08 04:28 AM
Correct me if I'm wrong - please. Emergency generator question [email protected] UK diy 25 September 25th 06 06:09 PM
Emergency generator question Tony Hayes UK diy 44 September 6th 03 07:58 AM


All times are GMT +1. The time now is 10:15 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"