Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,199
Default Using "old-work" hi-hats for new construction

I am doing a small room in my basement which will be sheetrocked. In
the past I have used new-work hi-hats, but I think it would be easier
to use old work hi-hats for 2 reasons.
1) Can put up ceiling first then cut hole instead of cutting out hole
before installing.
2) Can remove hi-hat to gain access to ceiling.

Anyone have inputs? Any disadvantages in doing this?
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,473
Default Using "old-work" hi-hats for new construction


"Mikepier" wrote in message
...
I am doing a small room in my basement which will be sheetrocked. In
the past I have used new-work hi-hats, but I think it would be easier
to use old work hi-hats for 2 reasons.
1) Can put up ceiling first then cut hole instead of cutting out hole
before installing.
2) Can remove hi-hat to gain access to ceiling.

Anyone have inputs? Any disadvantages in doing this?


The new work frames, are just a more durable installation.


  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,934
Default Using "old-work" hi-hats for new construction


I am doing a small room in my basement which will be sheetrocked. In
the past I have used new-work hi-hats, but I think it would be easier
to use old work hi-hats for 2 reasons.
1) Can put up ceiling first then cut hole instead of cutting out hole
before installing.
2) Can remove hi-hat to gain access to ceiling.

Anyone have inputs? Any disadvantages in doing this?




The new work frames, are just a more durable installation.




*I agree. The old work cans are only supported by the drywall unless you
install them next to a beam and drive a screw in. You would still have
access to the ceiling with new cans. They are made so that the "Can" can
drop down or be pushed up for access to the junction box. It is also easier
to lay out the recessed lights when you can see what obstacles will prevent
you from installing a light in a certain area.

  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,764
Default Using "old-work" hi-hats for new construction

On Sep 27, 11:16*pm, Mikepier wrote:
I am doing a small room in my basement which will be sheetrocked. In
the past I have used new-work hi-hats, but I think it would be easier
to use old work hi-hats for 2 reasons.
1) Can put up ceiling first then cut hole instead of cutting out hole
before installing.


With a Rotozip you'll get a pretty much perfect hole either way.

2) Can remove hi-hat to gain access to ceiling.


What's hiding above that light that needs access?

Anyone have inputs? Any disadvantages in doing this?


It's pretty much of a toss up in my mind. It's a basement and you're
the one doing the installation - your call.

R
  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 106
Default Using "old-work" hi-hats for new construction

*I agree. *The old work cans are only supported by the drywall unless you
install them next to a beam and drive a screw in. *You would still have
access to the ceiling with new cans. *They are made so that the "Can" can
drop down or be pushed up for access to the junction box. *It is also easier
to lay out the recessed lights when you can see what obstacles will prevent
you from installing a light in a certain area.


I was not aware that you can remove the can on a new work hi-hat. Next
time I go to Lowes I have to check it out.
Basically I need access to the ceiling in case I need to run
something in the future.


  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 50
Default Using "old-work" hi-hats for new construction

On Sep 28, 9:03*am, RicodJour wrote:
On Sep 27, 11:16*pm, Mikepier wrote:

I am doing a small room in my basement which will be sheetrocked. In
the past I have used new-work hi-hats, but I think it would be easier
to use old work hi-hats for 2 reasons.
1) Can put up ceiling first then cut hole instead of cutting out hole
before installing.


With a Rotozip you'll get a pretty much perfect hole either way.

2) Can remove hi-hat to gain access to ceiling.


What's hiding above that light that needs access?

Anyone have inputs? Any disadvantages in doing this?


It's pretty much of a toss up in my mind. *It's a basement and you're
the one doing the installation - your call.

R


I'll second the call for the Rotozip... if you don't have one, borrow/
rent it just for however many lights you have to put up... it will
make the cut much easier, and will come out looking perfect.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post