  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4
Default Winterize irrigation system - where to attach a compressor?

I have an irrigation system that I need to winterize. In the past I
used to hire a guy who installed the sprinklers but since I already
have the compressor and everything else I need, I'd rather save $70.
I've seen him hook up the compressor somewhere on the back low but I
don't know where. I was hoping that someone would be able to tell me
where to attach it and if there is anything else special I would need
to do.

Here are some pictures of my backflow:

http://www.medicfamily.com/tmp/DSC02319.JPG
http://www.medicfamily.com/tmp/DSC02320.JPG
http://www.medicfamily.com/tmp/DSC02321.JPG

Thanks!
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,926
Default Winterize irrigation system - where to attach a compressor?

On Nov 20, 6:56*pm, Mensur wrote:
I have an irrigation system that I need to winterize. In the past I
used to hire a guy who installed the sprinklers but since I already
have the compressor and everything else I need, I'd rather save $70.
I've seen him hook up the compressor somewhere on the back low but I
don't know where. I was hoping that someone would be able to tell me
where to attach it and if there is anything else special I would need
to do.

Here are some pictures of my backflow:

http://www.medicfamily.com/tmp/DSC02...p/DSC02321.JPG

Thanks!


How big is your compressor, mine is to small it has to little
volume, the one my sprinkler co uses is a big unit towed behind their
truck im sure if they only needed a small unit that is what they would
always use.

What do you do to keep the backflow preventer from freezing, I see
no lower drain provision, I remove mine it has a flange that unbolts
easily and I dont see that on yours, where do you live and how has
that been protected in the past as mine would have been ruined by now,
its 19 this morning. I see a spigot on the pipe from the backflow, I
will bet air goes there and clears the backflow out, if its gotten
under 32f for any length of time already you will have a $350 junk
backflow valve by now, and yours is not a 5 minute removal like mine.
I would change that set up so you have 2 easy to unbolt flanges, if
any water leaks past the interior shutoff it will settle at the bottom
of the backflow and freeze if an interior line drain is left closed,
mine leaks. My backflow was a 550 instal.

If it was my backflow Id sawzall off the valve at the vertical pipe
and be safe this winter, and next year put on a quick remove flange,
whare do you live.
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4
Default Winterize irrigation system - where to attach a compressor?

On Nov 21, 6:52*am, ransley wrote:
On Nov 20, 6:56*pm, Mensur wrote:

I have anirrigationsystem that I need towinterize. In the past I
used to hire a guy who installed the sprinklers but since I already
have the compressor and everything else I need, I'd rather save $70.
I've seen him hook up the compressor somewhere on the back low but I
don't know where. I was hoping that someone would be able to tell me
where to attach it and if there is anything else special I would need
to do.


Here are some pictures of my backflow:


http://www.medicfamily.com/tmp/DSC02...edicfamily.com...


Thanks!


* How big is your compressor, mine is to small it has to little
volume, the one my sprinkler co uses is a big unit towed behind their
truck im sure if they only needed a small unit that is what they would
always use.

* What do you do to keep the backflow preventer from freezing, I see
no lower drain provision, I remove mine it has a flange that unbolts
easily and I dont see that on yours, where do you live and how has
that been protected in the past as mine would have been ruined by now,
its 19 this morning. I see a spigot on the pipe from the backflow, I
will bet air goes there and clears the backflow out, if its gotten
under 32f for any length of time already you will have a $350 junk
backflow valve by now, and yours is not a 5 minute removal like mine.
I would change that set up so you have 2 easy to unbolt flanges, if
any water leaks past the interior shutoff it will settle at the bottom
of the backflow and freeze if an interior line drain is left closed,
mine leaks. My backflow was a 550 instal.

*If it was my backflow Id sawzall off the valve at the vertical pipe
and be safe this winter, and next year put on a quick remove flange,
whare do you live.


I live is South Carolina - it doesn't get too cold but it definetely
gets below 32F. I didn't do my winterization in the past - a guy that
installed the system did it before so I am not sure how he did it.
While he was there, all I could notice is that he attached a small
portable compressor and blew the water out.

I have a 33 gallon compressor that should do the trick especially if
the company was able to do it with a small portable compressor.

One thing I didn't mention is that I have a separate water meter and a
separate line for my irrigation so spigot on the house is not fed from
the same line.
  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,500
Default Winterize irrigation system - where to attach a compressor?

On Nov 21, 9:28*am, Mensur wrote:
On Nov 21, 6:52*am, ransley wrote:





On Nov 20, 6:56*pm, Mensur wrote:


I have anirrigationsystem that I need towinterize. In the past I
used to hire a guy who installed the sprinklers but since I already
have the compressor and everything else I need, I'd rather save $70.
I've seen him hook up the compressor somewhere on the back low but I
don't know where. I was hoping that someone would be able to tell me
where to attach it and if there is anything else special I would need
to do.


Here are some pictures of my backflow:


http://www.medicfamily.com/tmp/DSC02...edicfamily.com....


Thanks!


* How big is your compressor, mine is to small it has to little
volume, the one my sprinkler co uses is a big unit towed behind their
truck im sure if they only needed a small unit that is what they would
always use.


* What do you do to keep the backflow preventer from freezing, I see
no lower drain provision, I remove mine it has a flange that unbolts
easily and I dont see that on yours, where do you live and how has
that been protected in the past as mine would have been ruined by now,
its 19 this morning. I see a spigot on the pipe from the backflow, I
will bet air goes there and clears the backflow out, if its gotten
under 32f for any length of time already you will have a $350 junk
backflow valve by now, and yours is not a 5 minute removal like mine.
I would change that set up so you have 2 easy to unbolt flanges, if
any water leaks past the interior shutoff it will settle at the bottom
of the backflow and freeze if an interior line drain is left closed,
mine leaks. My backflow was a 550 instal.


*If it was my backflow Id sawzall off the valve at the vertical pipe
and be safe this winter, and next year put on a quick remove flange,
whare do you live.


I live is South Carolina - it doesn't get too cold but it definetely
gets below 32F. I didn't do my winterization in the past - a guy that
installed the system did it before so I am not sure how he did it.
While he was there, all I could notice is that he attached a small
portable compressor and blew the water out.

I have a 33 gallon compressor that should do the trick especially if
the company was able to do it with a small portable compressor.

One thing I didn't mention is that I have a separate water meter and a
separate line for my irrigation so spigot on the house is not fed from
the same line.- Hide quoted text -

- Show quoted text -



I've never seen a backflow valve that looks like that. On the 2
systems I've done myself, they were the PVC type and there was a
regular PVC fitting with a plug on the supply side of the backflow. I
take out that plug and use appropriate sized bushings to fit a male
air chuck on it. That takes care of getting the water out of the
backflow preventer. I don't know anyone that removes the backflow
preventer, they just blow it out.

On your system, the equivalent point would be the right had side, but
I have no idea what kind of peculiar fitting with the little screw is
that we're looking at. Unless someone here is familiar with that
valve, you could see if you can find a data sheet for that particular
valve and figure out what it's all about. Of just pay one more time
and watch.

Also, I agree with Ransley on the volume issue. I can do mine with a
decent size portable shop compressor. Not sure how big the tank is,
but it's one of the old craftsman horizontal tanks, with 2 wheels and
pull handle like a cart. I can do mine OK with that, but I have 3
rotor heads per zone, maybe 5 smaller pop up heads on another zone,
etc. I recently used it at a friends house and while we got through
it, I doubt I'd do it again. He has a lot more heads, maybe 8 on some
zones. It's very marginal, because there isn't enough volume. On a
zone with 8, by the time you have 5 blowing air, so much volume is
being lost that it then takes a long time to get the rest of the water
out. Even when I do mine, I have to let the compressor build up to
80-100 lbs, then turn on the zone. I repeat that process until they
are clear. On mine that is usually going through all the zones
twice. On friends, I had to do that probably 10 times on some
zones. It took probably 3 hours to get through all 10 zones. And
while I have about 95% confidence level that there isn't enough water
left to damage anything, I can't be really sure. The pros use a tow
behind that can deliver VOLUME so it gets all the water out in one
easy shot.

One factor that I could change is I've been using the 1/4" coil up
flex hose on the compressor. NExt year I'm going to go to Harbor
Freight and get a 25 foot bigger diameter straight hose. I would
think that would help.
  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,926
Default Winterize irrigation system - where to attach a compressor?

On Nov 21, 8:28*am, Mensur wrote:
On Nov 21, 6:52*am, ransley wrote:





On Nov 20, 6:56*pm, Mensur wrote:


I have anirrigationsystem that I need towinterize. In the past I
used to hire a guy who installed the sprinklers but since I already
have the compressor and everything else I need, I'd rather save $70.
I've seen him hook up the compressor somewhere on the back low but I
don't know where. I was hoping that someone would be able to tell me
where to attach it and if there is anything else special I would need
to do.


Here are some pictures of my backflow:


http://www.medicfamily.com/tmp/DSC02...edicfamily.com....


Thanks!


* How big is your compressor, mine is to small it has to little
volume, the one my sprinkler co uses is a big unit towed behind their
truck im sure if they only needed a small unit that is what they would
always use.


* What do you do to keep the backflow preventer from freezing, I see
no lower drain provision, I remove mine it has a flange that unbolts
easily and I dont see that on yours, where do you live and how has
that been protected in the past as mine would have been ruined by now,
its 19 this morning. I see a spigot on the pipe from the backflow, I
will bet air goes there and clears the backflow out, if its gotten
under 32f for any length of time already you will have a $350 junk
backflow valve by now, and yours is not a 5 minute removal like mine.
I would change that set up so you have 2 easy to unbolt flanges, if
any water leaks past the interior shutoff it will settle at the bottom
of the backflow and freeze if an interior line drain is left closed,
mine leaks. My backflow was a 550 instal.


*If it was my backflow Id sawzall off the valve at the vertical pipe
and be safe this winter, and next year put on a quick remove flange,
whare do you live.


I live is South Carolina - it doesn't get too cold but it definetely
gets below 32F. I didn't do my winterization in the past - a guy that
installed the system did it before so I am not sure how he did it.
While he was there, all I could notice is that he attached a small
portable compressor and blew the water out.

I have a 33 gallon compressor that should do the trick especially if
the company was able to do it with a small portable compressor.

One thing I didn't mention is that I have a separate water meter and a
separate line for my irrigation so spigot on the house is not fed from
the same line.- Hide quoted text -

- Show quoted text -


Still, here we dont leave 350$ backflow preventers outside, address
that issue before its 32 out, maybe a 33 gallon will work, attach to
the hose fitting. You say it gets below 32, but does it freeze at pipe
depth.


  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4
Default Winterize irrigation system - where to attach a compressor?

On Nov 21, 10:17*am, ransley wrote:
On Nov 21, 8:28*am, Mensur wrote:





On Nov 21, 6:52*am, ransley wrote:


On Nov 20, 6:56*pm, Mensur wrote:


I have anirrigationsystem that I need towinterize. In the past I
used to hire a guy who installed the sprinklers but since I already
have the compressor and everything else I need, I'd rather save $70..
I've seen him hook up the compressor somewhere on the back low but I
don't know where. I was hoping that someone would be able to tell me
where to attach it and if there is anything else special I would need
to do.


Here are some pictures of my backflow:


http://www.medicfamily.com/tmp/DSC02...edicfamily.com...


Thanks!


* How big is your compressor, mine is to small it has to little
volume, the one my sprinkler co uses is a big unit towed behind their
truck im sure if they only needed a small unit that is what they would
always use.


* What do you do to keep the backflow preventer from freezing, I see
no lower drain provision, I remove mine it has a flange that unbolts
easily and I dont see that on yours, where do you live and how has
that been protected in the past as mine would have been ruined by now,
its 19 this morning. I see a spigot on the pipe from the backflow, I
will bet air goes there and clears the backflow out, if its gotten
under 32f for any length of time already you will have a $350 junk
backflow valve by now, and yours is not a 5 minute removal like mine.
I would change that set up so you have 2 easy to unbolt flanges, if
any water leaks past the interior shutoff it will settle at the bottom
of the backflow and freeze if an interior line drain is left closed,
mine leaks. My backflow was a 550 instal.


*If it was my backflow Id sawzall off the valve at the vertical pipe
and be safe this winter, and next year put on a quick remove flange,
whare do you live.


I live is South Carolina - it doesn't get too cold but it definetely
gets below 32F. I didn't do my winterization in the past - a guy that
installed the system did it before so I am not sure how he did it.
While he was there, all I could notice is that he attached a small
portable compressor and blew the water out.


I have a 33 gallon compressor that should do the trick especially if
the company was able to do it with a small portable compressor.


One thing I didn't mention is that I have a separate water meter and a
separate line for myirrigationso spigot on the house is not fed from
the same line.- Hide quoted text -


- Show quoted text -


Still, here we dont leave 350$ backflow preventers outside, address
that issue before its 32 out, maybe a 33 gallon will work, attach to
the hose fitting. You say it gets below 32, but does it freeze at pipe
depth.- Hide quoted text -

- Show quoted text -


There is nowhere to attach the compressor on the hose. The copper
pipes you see on each side of the backflow are solid and go into the
ground. There is nowhere to attach the compressor on those pipes. That
is why I'm confused. I looked up some information on the backflow and
the procedure they are recommending is to attach a compressor on the
pipe leading away from the backflow and close the valve on the left
side of the backflow to prevent the air going into the backflow. The
problem for me is that I have nowhere to attach it there - there is no
fitting.
  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 8,803
Default Winterize irrigation system - where to attach a compressor?


"Mensur" wrote in message
...
I have an irrigation system that I need to winterize. In the past I
used to hire a guy who installed the sprinklers but since I already
have the compressor and everything else I need, I'd rather save $70.
I've seen him hook up the compressor somewhere on the back low but I
don't know where. I was hoping that someone would be able to tell me
where to attach it and if there is anything else special I would need
to do.

Here are some pictures of my backflow:

http://www.medicfamily.com/tmp/DSC02319.JPG
http://www.medicfamily.com/tmp/DSC02320.JPG
http://www.medicfamily.com/tmp/DSC02321.JPG

Thanks!


Just looking at it, I'd guess that you want to connect to the inlet on the left,
so the backflow valve gets flushed in addition to the pipes. Close the left blue
valve, open the screwdriver valve on the left and the blue valve on the right.
Screw an air hose fitting to the screwdriver valve hook up the hose and turn on
the air. I don't really know if this will flush the valve sufficiently.

If there are control valves for zones, operate each with air pressure applied to
clear each zone.

You could look in the meter box for additional valves and fittings to allow you
to flush or drain the pipe from it also.

Some sprinkler systems have automatic drain valves to avoid all this. Just turn
off the water and open valves to relieve the pressure, and the automatic drain
valves open to let the water out at the appropriate low spots.



  #8   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4
Default Winterize irrigation system - where to attach a compressor?

On Nov 21, 12:33*pm, "Bob F" wrote:
"Mensur" wrote in message

...

I have anirrigationsystem that I need to winterize. In the past I
used to hire a guy who installed the sprinklers but since I already
have the compressor and everything else I need, I'd rather save $70.
I've seen him hook up the compressor somewhere on the back low but I
don't know where. I was hoping that someone would be able to tell me
where to attach it and if there is anything else special I would need
to do.


Here are some pictures of my backflow:


http://www.medicfamily.com/tmp/DSC02319.JPG
http://www.medicfamily.com/tmp/DSC02320.JPG
http://www.medicfamily.com/tmp/DSC02321.JPG


Thanks!


Just looking at it, I'd guess that you want to connect to the inlet on the left,
so the backflow valve gets flushed in addition to the pipes. Close the left blue
valve, open the screwdriver valve on the left and the blue valve on the right.
Screw an air hose fitting to the screwdriver valve hook up the hose and turn on
the air. I don't really know if this will flush the valve sufficiently.

If there are control valves for zones, operate each with air pressure applied to
clear each zone.

You could look in the meter box for additional valves and fittings to allow you
to flush or drain the pipe from it also.

Some sprinkler systems have automatic drain valves to avoid all this. Just turn
off the water and open valves to relieve the pressure, and the automatic drain
valves open to let the water out at the appropriate low spots.


I wasn't sure if you saw the arrow pointing to the left (meaning that
water flow is from right to left). In that case, the backflow would
not get flushed as you are suggesting. In addition, I read that you
really should not run the air through the backflow. Is that true?
  #9   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 157
Default Winterize irrigation system - where to attach a compressor?

On Nov 21, 8:04*am, wrote:

Also, I agree with Ransley on the volume issue. * I can do mine with a
decent size portable shop compressor. *Not sure how big the tank is,
but it's one of the old craftsman horizontal tanks, with *2 wheels and
pull handle like a cart. * I can do mine OK with that, but I have 3
rotor heads per zone, maybe 5 smaller pop up heads on another zone,
etc. *I recently used it at a friends house and while we got through
it, I doubt I'd do it again. *He has a lot more heads, maybe 8 on some
zones. * It's very marginal, because there isn't enough volume. * On a
zone with 8, by the time you have 5 blowing air, so much volume is
being lost that it then takes a long time to get the rest of the water
out. * Even when I do mine, I have to let the compressor build up to
80-100 lbs, then turn on the zone. *I repeat that process until they
are clear. *On mine that is usually going through all the zones
twice.


Can you crank down the adjusting screws on all the heads and open them
up one at a time, then close it and move on to the next? Start
upstream and work your way to the end of the run.

Kinda similar to the way I winterize my cabin in Flagstaff, one faucet
at a time. Done it that way for 8 years, haven't had a problem yet -
except for the DUH moment when I blew the water heater empty without
remembering to turn if off first - burned out both elements, but the
pipes were fine.

Jerry
  #10   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 8,803
Default Winterize irrigation system - where to attach a compressor?


"Mensur" wrote in message
...
On Nov 21, 12:33 pm, "Bob F" wrote:
"Mensur" wrote in message

...

I have anirrigationsystem that I need to winterize. In the past I
used to hire a guy who installed the sprinklers but since I already
have the compressor and everything else I need, I'd rather save $70.
I've seen him hook up the compressor somewhere on the back low but I
don't know where. I was hoping that someone would be able to tell me
where to attach it and if there is anything else special I would need
to do.


Here are some pictures of my backflow:


http://www.medicfamily.com/tmp/DSC02319.JPG
http://www.medicfamily.com/tmp/DSC02320.JPG
http://www.medicfamily.com/tmp/DSC02321.JPG


Thanks!


Just looking at it, I'd guess that you want to connect to the inlet on the
left,
so the backflow valve gets flushed in addition to the pipes. Close the left
blue
valve, open the screwdriver valve on the left and the blue valve on the right.
Screw an air hose fitting to the screwdriver valve hook up the hose and turn
on
the air. I don't really know if this will flush the valve sufficiently.

If there are control valves for zones, operate each with air pressure applied
to
clear each zone.

You could look in the meter box for additional valves and fittings to allow
you
to flush or drain the pipe from it also.

Some sprinkler systems have automatic drain valves to avoid all this. Just
turn
off the water and open valves to relieve the pressure, and the automatic drain
valves open to let the water out at the appropriate low spots.


I wasn't sure if you saw the arrow pointing to the left (meaning that
water flow is from right to left). In that case, the backflow would
not get flushed as you are suggesting. In addition, I read that you
really should not run the air through the backflow. Is that true?

I missed the arrow, so reverse my instructions. I'd call the manufacturer to
ask about the air issue if that is a concern.



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Irrigation system problem. JD Home Repair 4 March 16th 08 02:10 PM
Can I maintain irrigation system myself? [email protected] Home Ownership 4 November 5th 06 05:48 PM
Winterize Sprinkler System - Febco Backflow Scott Home Repair 6 October 21st 06 12:55 AM
irrigation system Bonnie Jean Home Repair 7 August 6th 05 03:24 AM
Irrigation system from lake Andy Home Repair 11 March 31st 05 03:16 PM


All times are GMT +1. The time now is 06:39 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"