Default Questions for electrical experts about whirlpool bath

I pulled the wall switch for the whirlpool bath off of my bathroom
wall to replace it because it got cracked accidently.

While replacing it I noticed that the black and white wires were wired
as normal with the load going through the switch. But I noticed the
bare ground wires were not connected which I thought was weird so I
connected them together. When I turned the breaker on it immediately
reset so then I unconnected the grounds it worked fine again.

The circuit breaker in the basement is a 20 amp dedicated GFCI
breaker. Is there something about the whirlpool being connected to the
GFCI in the panel that needs the grounds not to be wired together in
the wall switch. Thanks for any help!

Sheila

  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,199
Default Questions for electrical experts about whirlpool bath

If you can't determine what's causing the problem, the GFI breaker
will still work without the grounds connected as they only look at the
current in the hot and neutral. But it should still be determined
whats tripping the breaker.
  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 408
Default Questions for electrical experts about whirlpool bath

On Aug 16, 6:51*pm, wrote:
I pulled the wall switch for the whirlpool bath off of my bathroom
wall to replace it because it got cracked accidently.

While replacing it I noticed that the black and white wires were wired
as normal with the load going through the switch. But I noticed the
bare ground wires were not connected which I thought was weird so I
connected them together. When I turned the breaker on it immediately
reset so then I unconnected the grounds it worked fine again.

The circuit breaker in the basement is a 20 amp dedicated GFCI
breaker. Is there something about the whirlpool being connected to the
GFCI in the panel that needs the grounds not to be wired together in
the wall switch. Thanks for any help!

Sheila


this COULD be quite dangerous, do not use the whirlpool until you
figure out what is going on..

Mark
  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,934
Default Questions for electrical experts about whirlpool bath


wrote in message
...
I pulled the wall switch for the whirlpool bath off of my bathroom
wall to replace it because it got cracked accidently.

While replacing it I noticed that the black and white wires were wired
as normal with the load going through the switch. But I noticed the
bare ground wires were not connected which I thought was weird so I
connected them together. When I turned the breaker on it immediately
reset so then I unconnected the grounds it worked fine again.

The circuit breaker in the basement is a 20 amp dedicated GFCI
breaker. Is there something about the whirlpool being connected to the
GFCI in the panel that needs the grounds not to be wired together in
the wall switch. Thanks for any help!

Sheila



The grounds need to be connected. There is a problem somewhere that is
causing the GFI circuit breaker to trip. Try disconnecting the spa motor
and then see if the breaker trips with the grounds connected in the switch
box.

I usually install a GFI switch in the bathroom out of sight instead of a GFI
breaker in the circuit breaker panel.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
More about strengthening a floor for a whirlpool bath Art Home Repair 10 July 14th 07 04:13 PM
Whirlpool bath surround Art Home Repair 0 July 11th 07 04:29 AM
Wiring for A Whirlpool Bath Tim Blank UK diy 10 November 21st 05 06:05 PM
switched spur for whirlpool bath. [email protected] UK diy 6 May 13th 05 09:46 PM
Wiring in a whirlpool bath John Orrett UK diy 19 August 5th 04 06:09 PM


All times are GMT +1. The time now is 05:49 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"