Default conduit question for garage


I'm purchasing a house with an attached garage, and will be adding a
subpanel for use as a shop. The garage is already insulated and
drywalled, so I'll be running conduit (most likely EMT).

The most-filled run will have three 20A 120V circuits for outlets wired
with #12, and 2 30A circuits for 240V wired with #10. (One 240V for the
dust collector, and one for everything else.)

I'm currently planning to run a single #10 ground wire (bare or green)
to ground everything on this run. I think this meets code, but I'd like
confirmation.

Assuming the above is okay, I'll have 11 wires in that conduit. Given
that I'm allowed 11 #10 wires in a 3/4" conduit, does that sound like a
reasonable conduit fill? Max spacing between conduit openings will be
about 10 ft.

Since this is a one-man shop I'll only ever be using two tools at once,
maybe three if someone is helping. I'm working on the assumption that
my load diversity is enough that I can use the 70% ampacity derate for
10 conductors. Is this reasonable, or do I have to go down to the 50%?
Should I go with two 1/2" conduits instead of a single 3/4"?

Finally, what's the best way to pull this given that the various wires
are going to different places, and one of the 240V circuits is going
right to the end? Do I pull one section at a time with all the wires
for that section?

Thanks,

Chris
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
SE cable, conduit protected...and other electrical service remarks. [email protected] Home Repair 5 July 28th 06 07:24 PM
Vertical electrical wiring question. pbs Home Repair 11 June 11th 06 04:50 PM
OT Guns more Guns Cliff Metalworking 519 December 12th 04 05:52 AM
Simple question regarding Ceiling tiles and sound? lbbs UK diy 5 March 26th 04 01:36 AM
Simple question regarding Ceiling tiles and sound? lbbs Home Ownership 2 March 25th 04 07:03 PM


All times are GMT +1. The time now is 06:56 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"