Electrical - Wiring a sconce from a valence
I am currently in the design stage of my new kitchen. I plan to install new cabinets. In some cases, I plan to create a valence where two cabinets surround a window. I would like to hang a sconce in front of the window. Here is my plan, Attach a horizontal cabinet "ceiling" board to the surrounding cabinets to attach a ceiling box to hang the sconce from. I would run the electrical behind the drywall and expose it an inch or two above the cabinet "ceiling" board through a hole in the drywall with enough extra to attach it to the ceiling box. My question is, can I run the Romex (14/2-lights only) unprotected from the hole in the drywall to the ceiling box or do I need to protect it with metal sheathing? The height is ~7' 6" above the floor. Do you have any suggestions or modifications to this plan? Much appreciated and Happy Holidays, |
#2
Posted to alt.home.repair
|
|||
|
|||
Electrical - Wiring a sconce from a valence
"Bach" wrote in message oups.com... I am currently in the design stage of my new kitchen. I plan to install new cabinets. In some cases, I plan to create a valence where two cabinets surround a window. I would like to hang a sconce in front of the window. Here is my plan, Attach a horizontal cabinet "ceiling" board to the surrounding cabinets to attach a ceiling box to hang the sconce from. I would run the electrical behind the drywall and expose it an inch or two above the cabinet "ceiling" board through a hole in the drywall with enough extra to attach it to the ceiling box. My question is, can I run the Romex (14/2-lights only) unprotected from the hole in the drywall to the ceiling box or do I need to protect it with metal sheathing? The height is ~7' 6" above the floor. Do you have any suggestions or modifications to this plan? Much appreciated and Happy Holidays, I put a shelf across the top of a window ~3 feet. I used 1.25 thick material cause I wanted to put some weight on the shelf. I screwed the shelf in from the ends........ I found that anything more than 3 pounds in the middle deflected the shelf. Which for my purpose was ok. Sconces where I live are wall fixtures. Where as you may be talking about pendant/ceiling fixture. your going to need to protect the romex. Height is not a factor. Romex has to be protected if exposed. Wire mold is always an option. I "understand" that you may have forgotten the box that will need to be installed for the 'ceiling" board. Have fun with the remodel. |
#3
Posted to alt.home.repair
|
|||
|
|||
Electrical - Wiring a sconce from a valence
Ahh, yes. You are correct. I truly meant a pendant light.
Thank you for you feedback, |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Electrical wiring: what did I damage? | Home Repair | |||
Residential power wiring: mounting electrical box outside? | Home Repair | |||
Wiring Practise Q for dry lining boxes | UK diy | |||
Wiring "new" electrical circuit | Home Repair | |||
Electrical Wiring Grouping Factors in IEE Regs | UK diy |