Our old Carrier Weathermaker Furnace (Model 58SX080-BC-1) seems to be acting
abnormally. When heat is called for the exhaust fan motor starts up, the pilot kicks in approx 40 to 50 seconds later, if the pilot doesn't shut off, then the burners ignite, and the blower motor turns on and blows heat. the burner shuts off approx 40 to 50 seconds later with a pfffffft sound and the blower runs for another 30 or 40 seconds until chamber cools. It all starts over. Pilot lights, sometimes burner lights or pilot goes out, If burner lights, blower blows, but burner shuts off with the pfffffft sound.Meanwhile the temperature never gets to thermostat setting. I will be calling service department tomorrow, in mean time any suggestions or causes? Thanks for your help. |
#2
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
Well it turns out that the pressure sensor was shutting down the gas valve
due to restricted air flow caused by leaves in intake pipe. Removed leaves and furnace operates normally. Thanks any way. "Henry Gawluk" wrote in message .. . Our old Carrier Weathermaker Furnace (Model 58SX080-BC-1) seems to be acting abnormally. When heat is called for the exhaust fan motor starts up, the pilot kicks in approx 40 to 50 seconds later, if the pilot doesn't shut off, then the burners ignite, and the blower motor turns on and blows heat. the burner shuts off approx 40 to 50 seconds later with a pfffffft sound and the blower runs for another 30 or 40 seconds until chamber cools. It all starts over. Pilot lights, sometimes burner lights or pilot goes out, If burner lights, blower blows, but burner shuts off with the pfffffft sound.Meanwhile the temperature never gets to thermostat setting. I will be calling service department tomorrow, in mean time any suggestions or causes? Thanks for your help. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Old Carrier furnace: spark igniter | Home Repair | |||
Old Carrier furnace and heat-exchanger | Home Repair | |||
Carrier Gas Furnace - Ignition Lights But Nothing Else | Home Ownership | |||
Carrier 58GS Gas Furnace (20 yrs old): Blower removal | Home Repair | |||
Carrier variable speed gas furnace | Home Repair |