Default Is my over hang designed properly?

I am thinking about building an overhang from our shed to park my
trailers under. I am curious if my current design is structurally
sound. I am building in southern Maryland so there is some snow but not
much.

I would like to build 24 foot by 18 foot over hang. The slope of the
roof would be on the 18 foot span. The 24 foot side would but up
against my existing shed. The rafters would run the 18 foot span.

First is 6 4x4 posts sunk two feet in the ground enough? I think code
in my area is 18 inches. One post on each corner and one in the front
center and rear center.

Second do I need to use 2x6 or 2x8 for rafters? I am planning on puting
the rafters 24" on center.

I plans to sheath it with plywood and shingle it with cheapo fiberglass
shingles.

Is my plan sound?

Thanks Dan

  #2   Report Post  
Harry K
 
Posts: n/a
Default Is my over hang designed properly?


Home owner wrote:
I am thinking about building an overhang from our shed to park my
trailers under. I am curious if my current design is structurally
sound. I am building in southern Maryland so there is some snow but not
much.

I would like to build 24 foot by 18 foot over hang. The slope of the
roof would be on the 18 foot span. The 24 foot side would but up
against my existing shed. The rafters would run the 18 foot span.

First is 6 4x4 posts sunk two feet in the ground enough? I think code
in my area is 18 inches. One post on each corner and one in the front
center and rear center.

Second do I need to use 2x6 or 2x8 for rafters? I am planning on puting
the rafters 24" on center.

I plans to sheath it with plywood and shingle it with cheapo fiberglass
shingles.

Is my plan sound?

Thanks Dan


Not enough information. Using 6 posts I see 8' between posts on the
24" side per your description. What are you bridging them with to
support the rafters. Just as a WAG I would say that you need at a
minimum 2x8 rafters.

If you need a building permit, draw your plans out and take them in.
They will quite rapidly tell you if you are up to code. Of course the
drawback is that you will wind up building way beyond what you consider
adequate. In my case, for a 26x10' shed roof, had I built to their
specs I could have parked a D6 cat on it.

Harry K

  #3   Report Post  
Home owner
 
Posts: n/a
Default Is my over hang designed properly?

I was thinking of running 2x6s along the front and back to hold up the
raftres. I was thinking 4 12 foot 2x6. One on each side of the 4x4 with
a seam in the middle of the structure. I am not sure I want to mess
with getting a permit. But, unless I feel real comfortable witht he
information I get I will go that route.

Also what should the pitch on the roof be at a minimum?

  #4   Report Post  
DT
 
Posts: n/a
Default Is my over hang designed properly?

In article . com,
says...

I am thinking about building an overhang from our shed to park my
trailers under. I am curious if my current design is structurally
sound. I am building in southern Maryland so there is some snow but not
much.

I would like to build 24 foot by 18 foot over hang. The slope of the
roof would be on the 18 foot span. The 24 foot side would but up
against my existing shed. The rafters would run the 18 foot span.

First is 6 4x4 posts sunk two feet in the ground enough? I think code
in my area is 18 inches. One post on each corner and one in the front
center and rear center.

Second do I need to use 2x6 or 2x8 for rafters? I am planning on puting
the rafters 24" on center.

I plans to sheath it with plywood and shingle it with cheapo fiberglass
shingles.

Is my plan sound?

Thanks Dan



Your plan is not sound. First, you need to know the recommended snow load for
your area. I doubt that it is a very high figure in Maryland, so let's use some
common minimums for example, 10 psf dead load and 20 psf live (snow) load.

You won't even come close to spanning 18' using 2x8's on 16" centers, let alone
24". I just finished a 30' wide gable roof, and 2x8's on 16" centers just
squeaked by the code for the 15' span.

And your cross members along the 18' edge would need to be quite substantial to
span 8', they would require double 2x12's at least in my area.

Here is an online span calculator to play around with some figures:

http://www.awc.org/calculators/span/...rcalcstyle.asp

For starters use spruce-pine-fir in a #2 grade, that is the most common lumber
in your area.

Dennis

  #5   Report Post  
SQLit
 
Posts: n/a
Default Is my over hang designed properly?


"Home owner" wrote in message
ups.com...
I am thinking about building an overhang from our shed to park my
trailers under. I am curious if my current design is structurally
sound. I am building in southern Maryland so there is some snow but not
much.

I would like to build 24 foot by 18 foot over hang. The slope of the
roof would be on the 18 foot span. The 24 foot side would but up
against my existing shed. The rafters would run the 18 foot span.

First is 6 4x4 posts sunk two feet in the ground enough? I think code
in my area is 18 inches. One post on each corner and one in the front
center and rear center.

Second do I need to use 2x6 or 2x8 for rafters? I am planning on puting
the rafters 24" on center.

I plans to sheath it with plywood and shingle it with cheapo fiberglass
shingles.

Is my plan sound?

Thanks Dan


NO
You need to contact your building department. Your design does not take into
consideration, wind loading, and snow loading. I will bet you will end up
with more like 2x10's 16" on center.

I built a patio cover, 12 feet wide by 14 feet long, 3/8 ply and rolled
roofing.
I need 1 4x6 post and a beam pocket attached to the house. I needed a 4x
10 beam to support the 2x8's 24" on center. I was lucky that the footing
was already installed.
Footings for a patio cover are 3 feet by 3 feet by one foot deep attached to
the 4x6.
The damn thing cost one hell of a lot more than I had envisioned during
conception. Not sorry I spent the money, materials cost well over $5.00
bucks a square foot including the paint when I was finished.





  #6   Report Post  
frank-in-toronto
 
Posts: n/a
Default Is my over hang designed properly?

On 9 Nov 2005 08:13:10 -0800, "Home owner" wrote:

I was thinking of running 2x6s along the front and back to hold up the
raftres. I was thinking 4 12 foot 2x6. One on each side of the 4x4 with
a seam in the middle of the structure. I am not sure I want to mess
with getting a permit. But, unless I feel real comfortable witht he
information I get I will go that route.

i doubt if you will get a permit once you
check and find out that you need a fabulous
drawing (like a blueprint) and that you will have to
build so it will last thru 100 year-storms.

since it's only to cover a trailer, it might now
matter if a hurricane wind blows it away or
collapses it. but i would listen intently to the
advice you're getting and check those spans.
bigger is better. bear in mind that a housing
inspector might make you take it down so build it
with bolts that you can remove if you have to.
....thehick
  #7   Report Post  
Harry K
 
Posts: n/a
Default Is my over hang designed properly?


frank-in-toronto wrote:
On 9 Nov 2005 08:13:10 -0800, "Home owner" wrote:

I was thinking of running 2x6s along the front and back to hold up the
raftres. I was thinking 4 12 foot 2x6. One on each side of the 4x4 with
a seam in the middle of the structure. I am not sure I want to mess
with getting a permit. But, unless I feel real comfortable witht he
information I get I will go that route.


i doubt if you will get a permit once you
check and find out that you need a fabulous
drawing (like a blueprint) and that you will have to
build so it will last thru 100 year-storms.

...thehick


May not need blue prints. Many departments will accept well drawn
plans done by home-owners. Mine will. They do need to be -well- drawn
and require detail drawings of how you are going to frame corners,
doors, etc. Must also have all construction materials specified as to
size/type etc.

Harry K

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Lee Valley Rule designed for "lefties"? [email protected] Woodworking 7 June 3rd 05 03:52 PM
more fun with air conditioning J Jensen Home Repair 93 September 7th 04 10:39 AM
more fun with air conditioning J Jensen Home Ownership 56 September 7th 04 06:20 AM
Carpet Not Designed for Pad or Tack Strip? Dan Home Repair 2 September 6th 03 11:03 PM
Roughing Gouges - Poorly Designed? George Woodturning 6 July 14th 03 11:59 PM


All times are GMT +1. The time now is 04:02 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"