AC question
I have lived in this house since it was new, 20 years ago. This past
week, during the late afternoon, I would get condensation coming from the air outlet closest to the air handler and right after the coil. I remember reading on this group that this is probably caused by icing of the coil. remembering that low air movement across the coil could cause this, I changed the filter and this time used a filter that would allow more flow ( I had one of those super duper ones that wouldn't let any pollen through). For the next day or so, that seemed to fix the problem. Now today, It has started again. I turned the AC off for about an hour, then turned it back on and no more condensation dripping from the outlet. I know, however, that it will probably return in another couple of hours. It is presently 100 degrees outside. The humidity is about 40%. Inside the temp is 77 degrees with a humidity of about 33%. This is the situation. The compressor is out side. Everything else is inside in the attic. Over the life of the AC, the filters have NOT be changed out on a regular basis. For the first 15 years or so, I used the el-chepo filters. Usually, when I did remember to change them, they were clogged up with dust. Last year I had someone come out to do a checkup. This was the first time in about 10 years. He measured the flow from the vents and used the gauges (I have no idea what the measurements were but he said the readings all looked good). He also checked the temp of the air coming out of the vents. All was good for the unit I had. He of course tried to sell me a new high effency unit, but when we finished talking, the payback would be after I was dead. So now I'm thinking that one of two things is wrong. Either the coil is clogged up and won't allow enough air to flow through the coil and it therefore freezes up, or the freon level is low(?). There seems to be good air flow coming from the vents and the air is cool, but can the air get around the coil? Or is it possible that some of the coil is clogged and that's where the ice starts to form, and then it just gets worse from there? I know I'm going to have to call an AC guy out, but I'd like to have an idea of what else the problem could be. Thanks. Dave |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Good morning or good evening depending upon your location. I want to ask you the most important question of your life. Your joy or sorrow for all eternity depends upon your answer. The question is: Are you saved? It is not a question of how good | Woodworking | |||
To anyone sick of alt.hvac | Home Repair | |||
OT Guns more Guns | Metalworking | |||
Plumbing Question | UK diy | |||
Question????? | Woodworking |