dehumidfier problem
I have a dehumidifier in my basement that has run faithfully for more than a
decade. This year it has been freezing up for the first time ever. I removed the case and cleaned it thoroughly but it still freezes up. I just noticed that the exhaust air is exiting the front of the unit. Since the cooling coils are on the back side and the heat side coils are towards the front, this seems backwards to me. Shouldn't it be blowing warm moist air over the cooling coils? It seems like the fan motor is running backwards. Am I wrong in thinking it should be exhausting out the back? Is it possible for an AC fan motor to suddenly begin running backwards? HELP! Thanks : ) |
#2
|
|||
|
|||
Don't even think about it any more. Decade old dehumidifiers are very
inefficient. Buy a new one for $200. I believe LG comes with a 5 year parts and labor warranty but you should verify that. "DonC" wrote in message ... I have a dehumidifier in my basement that has run faithfully for more than a decade. This year it has been freezing up for the first time ever. I removed the case and cleaned it thoroughly but it still freezes up. I just noticed that the exhaust air is exiting the front of the unit. Since the cooling coils are on the back side and the heat side coils are towards the front, this seems backwards to me. Shouldn't it be blowing warm moist air over the cooling coils? It seems like the fan motor is running backwards. Am I wrong in thinking it should be exhausting out the back? Is it possible for an AC fan motor to suddenly begin running backwards? HELP! Thanks : ) |
#3
|
|||
|
|||
DonC wrote: I have a dehumidifier in my basement that has run faithfully for more than a decade. This year it has been freezing up for the first time ever. I removed the case and cleaned it thoroughly but it still freezes up. I just noticed that the exhaust air is exiting the front of the unit. Since the cooling coils are on the back side and the heat side coils are towards the front, this seems backwards to me. Shouldn't it be blowing warm moist air over the cooling coils? It seems like the fan motor is running backwards. Am I wrong in thinking it should be exhausting out the back? Is it possible for an AC fan motor to suddenly begin running backwards? HELP! Thanks : ) Hi, I just noticed that the exhaust air is exiting the front of the unit. Since the cooling coils are on the back side and the heat side coils are towards the front That is correct. Moisture from the air is left on the cooling coils and the air comming out of the dehimidifier is slightly warmer than it went in. This year it has been freezing up for the first time ever. Room temp too cool, dirty coils, slow air fan, low refrigerant charge ( leak ), system restriction are some likely/possible trouble makers. jeff. Appliance Repair Aid http://www.applianceaid.com/ |
#4
|
|||
|
|||
"Appliance Repair Aid" wrote in message oups.com... DonC wrote: I have a dehumidifier in my basement that has run faithfully for more than a decade. This year it has been freezing up for the first time ever. I removed the case and cleaned it thoroughly but it still freezes up. I just noticed that the exhaust air is exiting the front of the unit. Since the cooling coils are on the back side and the heat side coils are towards the front, this seems backwards to me. Shouldn't it be blowing warm moist air over the cooling coils? It seems like the fan motor is running backwards. Am I wrong in thinking it should be exhausting out the back? Is it possible for an AC fan motor to suddenly begin running backwards? HELP! Thanks : ) Hi, I just noticed that the exhaust air is exiting the front of the unit. Since the cooling coils are on the back side and the heat side coils are towards the front That is correct. Moisture from the air is left on the cooling coils and the air comming out of the dehimidifier is slightly warmer than it went in. Over the "waste heat" coils first and then through the cooling cools last? That's my unanswered question. This year it has been freezing up for the first time ever. Room is same temperature as in prior years; coils are freshly cleaned; fan is not slow; no external system restrictions. That leaves internal restrictions or low refrigerant charge. But it's making ice at a very efficient rate : ) That's why I questioned the air flow. Room temp too cool, dirty coils, slow air fan, low refrigerant charge ( leak ), system restriction are some likely/possible trouble makers. jeff. Appliance Repair Aid http://www.applianceaid.com/ |
#5
|
|||
|
|||
"DonC" wrote in message ... snip Over the "waste heat" coils first and then through the cooling cools last? That's my unanswered question. This would not be a good setup. The dehumidifier must cool the incoming air to below the dew point at the time before the moisture will condense out of the air. If you pre-heated the air it'd have to run longer and it'd pull less moisture out of the air. Warmer air isn't more moist than dry per se, it's less moist than it'd be if it were cooler. Your dehumidifier isn't running backward. It's getting old. If it did come with anti-freeze protection perhaps whatever senses a freez-up condition isn't working any more. A new dehumidifier would be a wise investment. It'd use less electricity when it is running, and it'd have to run less overall. |
#6
|
|||
|
|||
**Over the "waste heat" coils first and then through the cooling cools
last?** Other way around... http://www.applianceaid.com/dehumidifier.html#how **But it's making ice at a very efficient rate : )** New style icemaker jeff. Appliance Repair Aid http://www.applianceaid.com/ |
#7
|
|||
|
|||
Thanks! Just what I wanted to know. Time for a replacement.
"Olaf" wrote in message ... "DonC" wrote in message ... snip Over the "waste heat" coils first and then through the cooling cools last? That's my unanswered question. This would not be a good setup. The dehumidifier must cool the incoming air to below the dew point at the time before the moisture will condense out of the air. If you pre-heated the air it'd have to run longer and it'd pull less moisture out of the air. Warmer air isn't more moist than dry per se, it's less moist than it'd be if it were cooler. Your dehumidifier isn't running backward. It's getting old. If it did come with anti-freeze protection perhaps whatever senses a freez-up condition isn't working any more. A new dehumidifier would be a wise investment. It'd use less electricity when it is running, and it'd have to run less overall. |
#8
|
|||
|
|||
"Appliance Repair Aid" wrote in message oups.com... **Over the "waste heat" coils first and then through the cooling cools last?** Other way around... http://www.applianceaid.com/dehumidifier.html#how That's what i was looking for! Thanks **But it's making ice at a very efficient rate : )** New style icemaker jeff. Appliance Repair Aid http://www.applianceaid.com/ |
#9
|
|||
|
|||
Warm air holds more moisture, so dumping ehat out the front is normal. After
all, the coils are designed to cool the air. Harder to cool warm air. Sounds like it's low on freon, which will make it run at a lower temp. Very few AC / refrig guys work on dehumidifiers. You may be able to find someone who can juice it up. Some dehumidifiers come with a "freeze stat". Which turns the power off if the coil freezes. -- Christopher A. Young Learn more about Jesus www.lds.org www.mormons.com "DonC" wrote in message ... I have a dehumidifier in my basement that has run faithfully for more than a decade. This year it has been freezing up for the first time ever. I removed the case and cleaned it thoroughly but it still freezes up. I just noticed that the exhaust air is exiting the front of the unit. Since the cooling coils are on the back side and the heat side coils are towards the front, this seems backwards to me. Shouldn't it be blowing warm moist air over the cooling coils? It seems like the fan motor is running backwards. Am I wrong in thinking it should be exhausting out the back? Is it possible for an AC fan motor to suddenly begin running backwards? HELP! Thanks : ) |
#10
|
|||
|
|||
It's been retired : )
"Stormin Mormon" wrote in message ... Warm air holds more moisture, so dumping ehat out the front is normal. After all, the coils are designed to cool the air. Harder to cool warm air. Sounds like it's low on freon, which will make it run at a lower temp. Very few AC / refrig guys work on dehumidifiers. You may be able to find someone who can juice it up. Some dehumidifiers come with a "freeze stat". Which turns the power off if the coil freezes. -- Christopher A. Young Learn more about Jesus www.lds.org www.mormons.com "DonC" wrote in message ... I have a dehumidifier in my basement that has run faithfully for more than a decade. This year it has been freezing up for the first time ever. I removed the case and cleaned it thoroughly but it still freezes up. I just noticed that the exhaust air is exiting the front of the unit. Since the cooling coils are on the back side and the heat side coils are towards the front, this seems backwards to me. Shouldn't it be blowing warm moist air over the cooling coils? It seems like the fan motor is running backwards. Am I wrong in thinking it should be exhausting out the back? Is it possible for an AC fan motor to suddenly begin running backwards? HELP! Thanks : ) |
#11
|
|||
|
|||
You go over the cooling coils first to drop the air as far as possible
below it's dew point. Then you reheat it to get its temperature as far as possible above the new dew point, now that moisture has been removed. Stretch |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Outside drain problem... Who is responsible? | UK diy | |||
SONY 35" Dual PIP -Video Blackout Problem | Electronics Repair | |||
Paslode IM250A Cordless Finish Nailer, Stripped Treads Problem | Woodworking | |||
Widespread problem with HP Omnibook XE3-GFs? | Electronics Repair | |||
Problem with retrace lines on EIZO F55S... | Electronics Repair |