Hello,
I had posted this in alt.building.construction but I only got one responce... I'm in the process of building a new house here in the Atlantic part of Canada. I'm looking at 3 way's of doing it: First: 2x6(on 16" center) lumber, 7/16 Aspenite OSB with R-20x15 bat insulation Second: 2x6(on 24" center) lumber, 7/16 Aspenite OSB with R-20x23 bat insulation Third: 2x4(on 16" center) lumber, 2" expanded polystyrene(R-8) with R-12x15 bat insulation and wind brace Most of the houses around here are done like the fist one. There are also a few contractors doing: 2x6(on 16" center) lumber, 1" 1/2 extruded polystyrene (R-7.5) with R-20x15 bat insulation. I'm king off looking at option 3 because it is the less expansive way and it seem to make more sense. It has the same R value of the fist one but you have extra "protection" on the studs (no thermal transfer, or less since you have a R-8 value covering it). What are your points on this? ThanksCh ristian |
#2
![]() |
|||
|
|||
![]()
Consider a higher R foamboard R 7.2" foilfaced, Your total R values are
far from optimal if cost is not the issue. Consider sprayed in foam for highest R |
#3
![]() |
|||
|
|||
![]()
You can't do 24" o/c for ext stud walls per code. Seriously consider
Exyterior Synthetic Stucco, goto www. durabond.com and read up on it. This finish is growing in leaps and bounds because of insulation value and durability of finish. BTW you can't apply synthetic stucco over blue board. -- Remove the obvious to reply. Experienced and reliable Concrete Finishing and Synthetic Stucco application in the GTA. "m Ransley" wrote in message ... Consider a higher R foamboard R 7.2" foilfaced, Your total R values are far from optimal if cost is not the issue. Consider sprayed in foam for highest R |
#4
![]() |
|||
|
|||
![]()
You can't do 24" o/c for ext stud walls per code.
On what planet ? |
#5
![]() |
|||
|
|||
![]()
Rudy wrote:
You can't do 24" o/c for ext stud walls per code. On what planet ? The planet Ur anus. Watch that canuck... |
#6
![]() |
|||
|
|||
![]()
y
"ConcreteFinishing&StuccoGuy" wrote in message .. . You can't do 24" o/c for ext stud walls per code. Seriously consider Exyterior Synthetic Stucco, goto www. durabond.com and read up on it. This snip yep the code allows it here... :c) Christian |
#7
![]() |
|||
|
|||
![]()
"Christian" writes:
"ConcreteFinishing&StuccoGuy" wrote in You can't do 24" o/c for ext stud walls per code. Seriously consider [...] yep the code allows it here... :c) So I'm curious... about a related construction practice. What about staggered 2x4... What is the typical spacing-- 16"? Would you use a 6 or 8 inch top/sill plate? (if i have terminology correct) You'll have less thermal bridging, and more room for insulation. Have you considered that? (contractors: Is this practice done much these days? What about fire blocking?) also consider spray foam or wet pack cellulose. I think cellulose is R4/inch. you'd have around R24 with the 6 inch space. Foam is aroun R7/inch. (www.fomofoam.com is the only place i know that does DIY foam... always looking for other sources though) Just a thougt. ( or two...) -- be safe. flip Ich habe keine Ahnung was das bedeutet, oder vielleicht doch? Remove origin of the word spam from address to reply (leave "+") |
#8
![]() |
|||
|
|||
![]() "G Henslee" wrote in message ... Rudy wrote: You can't do 24" o/c for ext stud walls per code. On what planet ? The planet Ur anus. Watch that canuck... Well on all other planets I've been to, 2 X 6 Ext studwalls are OK. That goes for Canuckia (all the new homes around here going up that way, 1 2,and 3 story, including mine and the one next door they just put the walls up on over tha last week) IIRC our place in Arizona was the same. R |