Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Junior Member
 
Posts: 3
Default Replacing the FBT RCA 239111

Can someone point me to the correct procedure for replacing the FBT? It is a RCA 239111. All help is much appreciated.
  #2   Report Post  
 
Posts: n/a
Default

While not all encompassing, this is a good little how-to. I must warn
you. If you have not done this before, there is a risk of injury from
high voltages so be forewarned and read up on discharging the CRT. Good
luck.

http://www.macopz.com/columns/imacrepair/

  #3   Report Post  
Leonard Caillouet
 
Posts: n/a
Default

Make sure the replacement is not dated in summer of 2004. Apparently most
of that batch are failing. This is one case where I might look for an
aftermarket sub, preferably from HR. However, it is best not to mess with
it if you don't have experience working on television output stages.

Leonard

"RodG" wrote in message
...

Can someone point me to the correct procedure for replacing the FBT? It
is a RCA 239111. All help is much appreciated.


--
RodG



  #4   Report Post  
Art
 
Posts: n/a
Default

Check our the http://repairfaq.ece.drexel.edu/REPAIR site produced by Sam
Goldwasser, great reading on safety and general repair procedures.
"Leonard Caillouet" wrote in message
news:rPS2e.96459$SF.73419@lakeread08...
Make sure the replacement is not dated in summer of 2004. Apparently most
of that batch are failing. This is one case where I might look for an
aftermarket sub, preferably from HR. However, it is best not to mess with
it if you don't have experience working on television output stages.

Leonard

"RodG" wrote in message
...

Can someone point me to the correct procedure for replacing the FBT? It
is a RCA 239111. All help is much appreciated.


--
RodG





  #5   Report Post  
Junior Member
 
Posts: 3
Default

[quote=Art]Well I do build computers as a hobby with out any problem. You all really shared some valuable information regarding the safety of this part. I know for a fact it is this part and I will see if I can find the information unless someone has the instructions on discharging the FBT. I really want to be caustious. Thanks for the continued help.


  #6   Report Post  
James Sweet
 
Posts: n/a
Default


"RodG" wrote in message
...

Art Wrote:
Well I do build computers as a hobby with out any problem. You all
really shared some valuable information regarding the safety of this
part. I know for a fact it is this part and I will see if I can find
the information unless someone has the instructions on discharging the
FBT. I really want to be caustious. Thanks for the continued help.




The flyback doesn't store any charge, just leave the set off for a few
minutes and it should discharge itself, then to be doubly safe, ground a
screwdriver to the metal strap around the back of the tube and poke it under
the suction cup looking anode cap, if there's any charge remaining you might
hear a small snap of static electricity as it discharges.


  #7   Report Post  
kip
 
Posts: n/a
Default

Do NOT try and discharge under the Anode cap.
Just leave that alone ...
kip
"James Sweet" wrote in message
news:N6r3e.3061$pU5.93@trnddc06...

"RodG" wrote in message
...

Art Wrote:
Well I do build computers as a hobby with out any problem. You all
really shared some valuable information regarding the safety of this
part. I know for a fact it is this part and I will see if I can find
the information unless someone has the instructions on discharging the
FBT. I really want to be caustious. Thanks for the continued help.




The flyback doesn't store any charge, just leave the set off for a few
minutes and it should discharge itself, then to be doubly safe, ground a
screwdriver to the metal strap around the back of the tube and poke it
under
the suction cup looking anode cap, if there's any charge remaining you
might
hear a small snap of static electricity as it discharges.




  #8   Report Post  
James Sweet
 
Posts: n/a
Default


"kip" wrote in message
.. .
Do NOT try and discharge under the Anode cap.
Just leave that alone ...
kip



How do you recommend he replaces the flyback without messing with the anode
cap? If it's a direct view set then they're attached.


  #9   Report Post  
kip
 
Posts: n/a
Default

Chances are its a Pro Set
kip
"James Sweet" wrote in message
news:eRB3e.395$3O2.291@trnddc01...

"kip" wrote in message
.. .
Do NOT try and discharge under the Anode cap.
Just leave that alone ...
kip



How do you recommend he replaces the flyback without messing with the
anode
cap? If it's a direct view set then they're attached.




  #10   Report Post  
kip
 
Posts: n/a
Default

Not to mention they come with New Wire with Cap just pull ot of Flyback.

kip
"kip" wrote in message
.. .
Chances are its a Pro Set
kip
"James Sweet" wrote in message
news:eRB3e.395$3O2.291@trnddc01...

"kip" wrote in message
.. .
Do NOT try and discharge under the Anode cap.
Just leave that alone ...
kip



How do you recommend he replaces the flyback without messing with the
anode
cap? If it's a direct view set then they're attached.








  #11   Report Post  
Junior Member
 
Posts: 3
Default

Well I guess I should have mentioned its a GE 46 inch projection TV about 5 years old. It appears ro be rather straightfoward but I don't want to leave my wife and kids without their main support. Is there a way to use a meter to check if it is retaining a charge?


  #12   Report Post  
Art
 
Posts: n/a
Default

These sets drain the charges to reference quite effectively, proper safety
procedures should produce no nasty suprises. Just be absolutely sure the HV
lead is inserted into the HV block properly when done!!
"RodG" wrote in message
...

Well I guess I should have mentioned its a GE 46 inch projection TV
about 5 years old. It appears ro be rather straightfoward but I don't
want to leave my wife and kids without their main support. Is there a
way to use a meter to check if it is retaining a charge?


kip Wrote:
Not to mention they come with New Wire with Cap just pull ot of
Flyback.

kip
"kip" wrote in message
.. .-
Chances are its a Pro Set
kip
"James Sweet"
wrote in message
news:[email protected]

"kip"
wrote in message
.. .-
Do NOT try and discharge under the Anode cap.
Just leave that alone ...
kip-


How do you recommend he replaces the flyback without messing with the
anode
cap? If it's a direct view set then they're attached.

-

-



--
RodG



  #13   Report Post  
kip
 
Posts: n/a
Default

Yikes! Just pull out the Red cable...remove IHVT
Install new reinsert Red wire as per instructions .
Make sure the HOT is not S/C ..
kip

"RodG" wrote in message
...

Well I guess I should have mentioned its a GE 46 inch projection TV
about 5 years old. It appears ro be rather straightfoward but I don't
want to leave my wife and kids without their main support. Is there a
way to use a meter to check if it is retaining a charge?


kip Wrote:
Not to mention they come with New Wire with Cap just pull ot of
Flyback.

kip
"kip" wrote in message
.. .-
Chances are its a Pro Set
kip
"James Sweet"
wrote in message
news:[email protected]

"kip"
wrote in message
.. .-
Do NOT try and discharge under the Anode cap.
Just leave that alone ...
kip-


How do you recommend he replaces the flyback without messing with the
anode
cap? If it's a direct view set then they're attached.

-

-



--
RodG



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Replacing a radiator. Crewood UK diy 1 February 13th 05 04:33 PM
Replacing, enlarging, plus adding windows to brick home -- suggestions please... Alex Home Repair 3 October 11th 04 03:25 AM
Replacing taps. Mary Pegg UK diy 7 July 3rd 04 01:42 PM
Replacing hot water cylinder. Kevin UK diy 14 June 10th 04 05:26 PM
Near death boiler + replacing a boiler David Hearn UK diy 9 January 26th 04 12:44 PM


All times are GMT +1. The time now is 11:08 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"