Home |
Search |
Today's Posts |
![]() |
|
Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems. |
|
LinkBack | Thread Tools | Display Modes |
#6
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]()
Il 26/05/2019 17:40, Jeff Liebermann ha scritto:
On Thu, 23 May 2019 20:45:09 +0200, Eremita Analogico wrote: I have collected an old (80s) HT 1100A multimeter that seem a clone of a Fluke of that era. It mount a classic 7106 A/D converter that drive driectly a LCD display. When turned off, the display appear in good conditions, no black marks, brownings or burning signs. When I turn on the DMM, the display show almost all segments, except when the display is not 00.0 (that appear like 88.8) If I measure something that implies display to show fewer segments (like, i.e., 11.1) the reading is ok without ghost segments. If I reduce supply from 9V to around 4-5V, the display start to show 00.0 correctly, but with still some light ghost segments. Replacing the 7106 with another don't eliminate the problem. Do you think that I can try to solve? Thanks. The clock in the 7106 is not running. I would look at the 100pf or so capacitor on pin 38 of the 7106 for some kind of clock oscillator waveform: https://datasheets.maximintegrated.com/en/ds/ICL7106-ICL7107.pdf If there's no oscillation, and it's not one of the nearby components, the likely culprit is a blown 7016. Replacements are available: https://www.ebay.com/sch/i.html?_nkw=7106+a%2Fd Ok, thanks to all. I have checked the dual op-amp and the CD4070 and both is ok. I have checked the capacitor and resistor at pins 38, 39, 40 of 7106 (clock) and the values are correct, BUT if I power on the DMM without capacitor at pin 38 the display is perfect 00.0 without ghost segments (but obviously without any A/D conversion). This is a significant symptom? Replacing capacitor with another of same value (100p) make always display corrupted. I have 3 7106 and I checked with all, same problem. The display is mounted in a small PCB connected to main PCB through a flat plastic flexible "foil" with argent traces, pressed to pcbs with the plastic support of small display pcb. The resistence between every pin of 7106 and pads in small pcb is around 3 ohm. From small pcb to display there are classical siliconic conductive strips that I have carefully cleaned, together with plastic flexible foil. Where I can try to found the fault? Thanks. |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Searching for a good LCD display for a FLUKE 8010A DMM | Electronics Repair | |||
My Airplane display is not on Display! | Woodworking | |||
Spare parts for old Beckman DMM | Electronics Repair | |||
TFT display pinout / use laptop display separately? [palme7] | Electronics Repair | |||
Fluke 87 DMM differences >>>series III | Electronics Repair |