I heard power tools run on long cords go bad sooner. I assume because
of the voltage drop the motor runs slower. I am thinking that the
voltage drop is not a direct factor but slower speeds means less
airflow since they all have a fan on the shaft (except pass through
vacuums unless heavy duty. I remember in the seventies sears had a
vacuum that had two speeds. But I think it was controlled by the entry
point of the wire in motor, not a device that is like a dimmer made for
brush motors. I saw one on a centrifuge and after market for routers.


I am asking if lack of air flow from lower speeds due to voltage drops
damage power tools (skilsaw and such)

  #2   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 1,245
Default Can moters be run slower with less voltage (brush types)


"davidlaska" wrote in message
ups.com...

I am asking if lack of air flow from lower speeds due to voltage drops
damage power tools (skilsaw and such)


I wouldn't put much stock in it, but shorter, heavier cords are a good idea.
I'd be more concerned about low voltage at the outlets. Maybe your tools are
just cheap?







  #3   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 45
Default Can moters be run slower with less voltage (brush types)


Homer J Simpson wrote:
"davidlaska" wrote in message
ups.com...

I am asking if lack of air flow from lower speeds due to voltage drops
damage power tools (skilsaw and such)


I wouldn't put much stock in it, but shorter, heavier cords are a good idea.
I'd be more concerned about low voltage at the outlets. Maybe your tools are
just cheap?


I only hear about power tools like skill saws can be damaged. Never
had a tool go bad. I thought these motors can run at any speed if cool.

  #4   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 45
Default Can moters be run slower with less voltage (brush types)


Homer J Simpson wrote:
"davidlaska" wrote in message
ups.com...

I am asking if lack of air flow from lower speeds due to voltage drops
damage power tools (skilsaw and such)


I wouldn't put much stock in it, but shorter, heavier cords are a good idea.
I'd be more concerned about low voltage at the outlets. Maybe your tools are
just cheap?


I forgot to say that cheap tools do break quick, stuff from China, I am
not blaming them though, they deliver what the market will take.

What I thinks I am really asking is a long cord voltage drop similar to
after-market devices that slow down motors like a router?

  #5   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 1,572
Default Can moters be run slower with less voltage (brush types)



What I thinks I am really asking is a long cord voltage drop similar to
after-market devices that slow down motors like a router?




Similar, you're limiting the current though rather than effectively
using PWM so you'll get less torque with voltage drop than with a speed
controller, the motor shouldn't heat up more than usual though.

Induction motors on the other hand will overheat if the voltage drops.
They're constant power devices and lower voltage will cause higher
current to be drawn to compensate, higher current = more heat.


  #6   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 9,560
Default Can moters be run slower with less voltage (brush types)

davidlaska wrote:

I heard power tools run on long cords go bad sooner. I assume because


Dont believe everything. The only motors so affected are induction
motors, which are at times found in stationary tools but not hand
helds.

Reducing V reduces both power diss and airflow, and temp stays roughly
constant over a wide speed range.


NT

  #8   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 45
Default Can moters be run slower with less voltage (brush types)


James Sweet wrote:

What I thinks I am really asking is a long cord voltage drop similar to
after-market devices that slow down motors like a router?




Similar, you're limiting the current though rather than effectively
using PWM so you'll get less torque with voltage drop than with a speed
controller, the motor shouldn't heat up more than usual though.

Induction motors on the other hand will overheat if the voltage drops.
They're constant power devices and lower voltage will cause higher
current to be drawn to compensate, higher current = more heat.


Thankyou: it is popular among carpenters but they can continue thinking
that and get the large cords. I do not want to explain it unless asked.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Toshiba high voltage problem Bobby Villamor Electronics Repair 4 November 22nd 04 11:40 PM
Voltage Regulation Christoph M. Wintersteiger Electronics 1 June 14th 04 11:15 PM
voltage regulator that drops out of circuit CampinGazz Electronics 4 February 1st 04 07:14 PM
testing ATX power supply tempus fugit Electronics Repair 12 January 13th 04 05:03 PM
Understanding pull up resistors [email protected] Electronics Repair 6 October 20th 03 05:10 PM


All times are GMT +1. The time now is 01:56 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"