  #1   Report Post  
 
Posts: n/a
Default Gutters

Zenith had a collector for leaking coolant. NEC and Mits used gutters
for a time. Now we put gutters in set with very slow coolant leaks.

Quality ? VSXX43 series Mits, never been touched, had a broken red CRT
board causing ti to go bright red and shutdown. Problem is the customer
would turn the set right back on and the condition persisting with the
CRT filament still hot and the V sweep not yet started they burnt the
living **** out of the phosphor. Real bad, and they originally didn't
really want the red CRT, they said they could live with it. I estimated
the set and told them to sell the tube. The repair was simple, so $200
something for the red tube wasn't so bad.

So the people are very happy, until about 3 weeks later (this shop
gives a 180 day warranty but it is problem specific). The NEW CRT
leaked coolant all over the signal board ! Damn, it was NEW ! Thus the
gutters. What's more, in all these sets I've never seen them run low on
coolant so as to be noticable or cause CRT damage.

One poster in this forum said it is that the coolant expands over time
and I am a believer. I have fely those bellows, or diaphragms bulging
under alot of pressure. Perhaps this explains my 1973 Olds having
pressure in the radiator after sitting for six months without being
started.

Is it worth the time to relieve the pressure in the tubes rather than
install a gutter ?

Let's put it this way, I had a new tube leak, so the expansion is
probably not caused by use (heat and light) and probably continues
slowly. Now I wonder if there's a limit to this phemonenon, that it
stops after a certain point. Then one time I had a Zenith that had
porosity of the coolant chamber housing itself.

Gutters are fugly and I don't like doing it, forget about lead dress,
airflow is usually affected so it is not a perfect solution. I know an
ASC wouldn't usually install gutters when the product is under
warranty, and I happen to know of a shop that probably would NEVER do
it. I worked there and their attitude was "look at the name on the set,
do you want to put YOUR name on the set ?". What's more, if I got a
brand new CRT/chamber assy from the manufacturer, if I noticed a
bulging bellows and releived the pressure, I might void the warranty.

Damnned if you do, damnned if you don't and damnned if you choose not
to decide. I guess that's the new rule.

JURB

  #2   Report Post  
Jason D.
 
Posts: n/a
Default

On 18 Sep 2005 14:43:46 -0700, wrote:

Zenith had a collector for leaking coolant. NEC and Mits used gutters
for a time. Now we put gutters in set with very slow coolant leaks.


Is it worth the time to relieve the pressure in the tubes rather than
install a gutter ?

Let's put it this way, I had a new tube leak, so the expansion is
probably not caused by use (heat and light) and probably continues
slowly. Now I wonder if there's a limit to this phemonenon, that it
stops after a certain point. Then one time I had a Zenith that had
porosity of the coolant chamber housing itself.

Gutters are fugly and I don't like doing it, forget about lead dress,
Damnned if you do, damnned if you don't and damnned if you choose not
to decide. I guess that's the new rule.

JURB


Samsung now have a kit for installing catch-bag using set of covers
(they replaces the original covers held down with 3 screws), with
nipples and hoses to a stiff plastic bag. BUT! The biggest problem
with this is most of them is out of warranty and customer might not
foot the larger estimate to reconvgence all CRTs compared to replace a
leaking CRT with new CRT (Samsung sells complete unit (yoke, CRT and
lens as a assembly).

Unless caught early I can save samsung TV with leaking CRT by cleaning
up the spilt coolant and install the catch-bag system for similar
estimate.

Samsung also have snap-on individual catch bags ONLY for retangular 4
screw type which is older design. Be very careful to snap them on, it
takes very strong force to snap them on, the plastic claws is made of
very brittle plastic and cracks easily.

For RCA stuff, I also notice that expansion chambers (rubber) is very
extrended as inflated, even new. If they were collasped when cold,
fine but if fully popped out, leak down the future is a problem due to
coolant expansion as temps comes up. SPURT! Zzzzzzt crackle!.

I'm doing an RCA (PTK195) having to redo all seals and making sure the
expansion chambers are collapsed.

Cheers, Wizard
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
How much water allowed in gutters Jack Home Repair 3 September 2nd 05 04:34 PM
Question about installing gutters willshak Home Repair 5 August 29th 05 01:09 PM
Roof runoff overshooting gutters HerHusband Home Repair 4 May 20th 05 08:39 PM
Replacing facia boards behind gutters Tom Miller Home Repair 6 October 3rd 04 02:59 AM
Home inspection dilemma - missing gutters Jon Home Repair 36 May 21st 04 03:34 AM


All times are GMT +1. The time now is 04:40 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"