I have 5 inch "K-style" vinyl gutters on our house. To keep leaves and fir
needles out of the gutters, I have vinyl screens covering the top of the
gutters. They generally work well, except on the front and back of the
house where the roof valley's are.

The valley's channel a larger volume of water into one spot, and in some of
the significant rain storms, there's so much flow it overflows the gutter
at the point going all over the yard and down the side of the house.

To make matters worse, the valley's also collect larger amounts of fir
needles which get washed down and pile up on top of the gutter screen. This
basically builds a ramp for the water to come down the valley and straight
over the top of the gutter.

I could probably remove the gutter screen in that spot and collect more
water, but it would also allow debris to get in and clog up the gutters.

Any tips on what I can do to solve the problem? (Replacing the gutters is
not an option at this point).

Thanks,

Anthony
  #2   Report Post  
Duane Bozarth
 
Posts: n/a
Default

HerHusband wrote:

I have 5 inch "K-style" vinyl gutters on our house. To keep leaves and fir
needles out of the gutters, I have vinyl screens covering the top of the
gutters. They generally work well, except on the front and back of the
house where the roof valley's are.

The valley's channel a larger volume of water into one spot, and in some of
the significant rain storms, there's so much flow it overflows the gutter
at the point going all over the yard and down the side of the house.

To make matters worse, the valley's also collect larger amounts of fir
needles which get washed down and pile up on top of the gutter screen. This
basically builds a ramp for the water to come down the valley and straight
over the top of the gutter.

I could probably remove the gutter screen in that spot and collect more
water, but it would also allow debris to get in and clog up the gutters.

Any tips on what I can do to solve the problem? (Replacing the gutters is
not an option at this point).


Well, if you don't have enough surface area open to collect the water
and don't make such area available in one form or another, there isn't
much of a solution available....

Given the constraint, only thing I can think of that might help some
would be to install a vertical dam in the corner at the valley. The
make these preformed for the purpose. But, unless there's somewhere for
the water to get into the gutter, you'll simply see it run over around
the dam ends instead of directly over the top at the corner.
  #3   Report Post  
tom
 
Posts: n/a
Default

Install a piece of aluminium on the outer lip of the gutter, a simple
fix, done all the time. Tom

  #4   Report Post  
Blue
 
Posts: n/a
Default

Before you head off to HoDePo better be sure that your gutter isn't plugged
and just over flowing, or that your shield isn't covered with crap and just
sheeting off the water. You gotta get up there and look DOWN at the
problem.

"HerHusband" wrote in message
...
I have 5 inch "K-style" vinyl gutters on our house. To keep leaves and fir
needles out of the gutters, I have vinyl screens covering the top of the
gutters. They generally work well, except on the front and back of the
house where the roof valley's are.

The valley's channel a larger volume of water into one spot, and in some
of
the significant rain storms, there's so much flow it overflows the gutter
at the point going all over the yard and down the side of the house.

To make matters worse, the valley's also collect larger amounts of fir
needles which get washed down and pile up on top of the gutter screen.
This
basically builds a ramp for the water to come down the valley and straight
over the top of the gutter.

I could probably remove the gutter screen in that spot and collect more
water, but it would also allow debris to get in and clog up the gutters.

Any tips on what I can do to solve the problem? (Replacing the gutters is
not an option at this point).

Thanks,

Anthony



  #5   Report Post  
Andrew Neilson
 
Posts: n/a
Default


"HerHusband" wrote in message
...
I have 5 inch "K-style" vinyl gutters on our house. To keep leaves and fir
needles out of the gutters, I have vinyl screens covering the top of the
gutters. They generally work well, except on the front and back of the
house where the roof valley's are.

The valley's channel a larger volume of water into one spot, and in some

of
the significant rain storms, there's so much flow it overflows the gutter
at the point going all over the yard and down the side of the house.

To make matters worse, the valley's also collect larger amounts of fir
needles which get washed down and pile up on top of the gutter screen.

This
basically builds a ramp for the water to come down the valley and straight
over the top of the gutter.

I could probably remove the gutter screen in that spot and collect more
water, but it would also allow debris to get in and clog up the gutters.

Any tips on what I can do to solve the problem? (Replacing the gutters is
not an option at this point).

Thanks,

Anthony


Anthony
My father's house had the same issue. When it rained hard, the water
would flow down the 'valley' and totally overshoot the gutter. It was like
having a firehose squirting water on the porch. What we did was to take a
chunk of aluminum sheet (old snow shovel) and cut it into a rectangle about
12 inches by 6 inches. We then made a 3 inch cut (to the center) right at
the half way point of the 12 inch side. We folded it 90 degrees along the
12 inch axis, and then on the 'outside' of the "L" shape, we then created 3
inch flanges at 90 degrees as well. This gave us an "L" shaped piece of
metal, with 6 inch sides and a three inch flange to insert underneath the
shingles. We got some roofing tar and cemented the thing in place. When it
rained after than, the water would hit the upright three inch flange and be
redirected 90 degrees. This allowed the gutters to work properly and we had
no more problems.


Andrew


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Home inspection dilemma - missing gutters Jon Home Repair 36 May 21st 04 03:34 AM
Get a New Roof But Don't Add Any Ventilation? Jay Chan Home Repair 12 March 30th 04 05:16 PM
Anyone want some heart pine roof decking? woodyq Woodworking 1 March 29th 04 11:25 PM
Pitch and gravel roof? Terry UK diy 3 February 25th 04 02:43 PM
Pitch and gravel roof? Terry Home Repair 3 February 25th 04 02:43 PM


All times are GMT +1. The time now is 06:01 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"