Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Bob Shuman
 
Posts: n/a
Default Info on Western Electric Telephone Line Carbon Block Arrestor?

Looking for whatever information I can find (schematic, assembly drawing,
component listing, experts with knowledge of internals) on the following 40
or so year old component:

25 Line Carbon Lightning Arrestor/Protection #134A1A-25 that was
manufactured by Western Electric (manufacturing arm of the Bell System -
pre-AT&T divestiture) in the USA.

If anyone has information or can point me to a source for that information
it would be very much appreciated.

Thanks in advance,

Bob S.



  #2   Report Post  
Bob AZ
 
Posts: n/a
Default

Do a google search.
Bob AZ

  #3   Report Post  
**THE-RFI-EMI-GUY**
 
Posts: n/a
Default

I remember the FCC Part 68 had details for a lot of devices. You might
check CFR47 Part 68

Bob Shuman wrote:

Looking for whatever information I can find (schematic, assembly drawing,
component listing, experts with knowledge of internals) on the following 40
or so year old component:

25 Line Carbon Lightning Arrestor/Protection #134A1A-25 that was
manufactured by Western Electric (manufacturing arm of the Bell System -
pre-AT&T divestiture) in the USA.

If anyone has information or can point me to a source for that information
it would be very much appreciated.

Thanks in advance,

Bob S.






--
Joe Leikhim K4SAT
"The RFI-EMI-GUY"

The Lost Deep Thoughts By: Jack Handey
Before a mad scientist goes mad, there's probably a time
when he's only partially mad. And this is the time when he's
going to throw his best parties.
  #5   Report Post  
Bob Shuman
 
Posts: n/a
Default

Don, Yes this is exactly correct. It is a pre-wired carbon block assembly
that came with either a 6 foot or 12 foot cable and was used at commercial
customer premises for phone line lightning/surge protection. I know and
understand the basic function, but am looking for information on the
internal workings (what distance spark gap that breaks down under what
voltage and how quickly will it clamp and to what voltage through the carbon
block? What maximum current over what duration will it handle before it
fails? How much resistance is allowed in the ground path to work properly?
What gauge ground wire and maximum distance? ) An assembly drawing,
schematic, technical specifications, and such.

I've learned that it was manufacturer discontinued, some alternative
customer orderable end item (Comcode) numbers, the engineering control
location (Bell Labs, Whippany, NJ), the place of manufacture (Western
Electric, Baltimore Works - Long Gone), and the replacement (still active)
Lucent arrestor part number, but so far these have not led to any of the
desired info.

I've been given a lead on a microfilm number and have a friend looking into
Engineering Records to see if this is reproducible.

If anyone has other info please let me know. Thanks.

Bob

"Don Bowey" wrote in message
...
He won't find the protectors in Part 68.

What he has is the device Telco cable pairs are permanently wired to, to
protect people and equipment from high voltage in the event of a lightning
strike or having a cable cross with AC power. I don't have any info left

to
see what type it is; they came in many configurations..

It is also used at large customer premises for the same purpose, still as
telco equipment.

Don






  #6   Report Post  
**THE-RFI-EMI-GUY**
 
Posts: n/a
Default

Try this link below to a thread describing the wiring. Also CFR47 Part
68.306 may give an idea as to the voltage range. I think about 300 volts
is lower limit of these devices. They are troublesome. Several occasions
I have had phone lines with hum problems go unresolved until a
knowledgeable "phone man" replaced the cartridges.

http://www.mailarchive.ca/lists/comp...0-09/0046.html

Bob Shuman wrote:

Looking for whatever information I can find (schematic, assembly drawing,
component listing, experts with knowledge of internals) on the following 40
or so year old component:

25 Line Carbon Lightning Arrestor/Protection #134A1A-25 that was
manufactured by Western Electric (manufacturing arm of the Bell System -
pre-AT&T divestiture) in the USA.

If anyone has information or can point me to a source for that information
it would be very much appreciated.

Thanks in advance,

Bob S.






--
Joe Leikhim K4SAT
"The RFI-EMI-GUY"

The Lost Deep Thoughts By: Jack Handey
Before a mad scientist goes mad, there's probably a time
when he's only partially mad. And this is the time when he's
going to throw his best parties.
  #7   Report Post  
**THE-RFI-EMI-GUY**
 
Posts: n/a
Default

Bob; You work at Lucent and can't get this info? No wonder my stock went
from $37 to $2.84!

Bob Shuman wrote:

Looking for whatever information I can find (schematic, assembly drawing,
component listing, experts with knowledge of internals) on the following 40
or so year old component:

25 Line Carbon Lightning Arrestor/Protection #134A1A-25 that was
manufactured by Western Electric (manufacturing arm of the Bell System -
pre-AT&T divestiture) in the USA.

If anyone has information or can point me to a source for that information
it would be very much appreciated.

Thanks in advance,

Bob S.






--
Joe Leikhim K4SAT
"The RFI-EMI-GUY"

The Lost Deep Thoughts By: Jack Handey
Before a mad scientist goes mad, there's probably a time
when he's only partially mad. And this is the time when he's
going to throw his best parties.
  #8   Report Post  
Bob Shuman
 
Posts: n/a
Default

I have found info through internal sources, but there are a lot of people
out there in this newsgroup who know some stuff you can't find in archives.

So you bought "low" huh (at least compared to me...) But, I am one of the
few, the lucky, the proud ... who have managed to stay employed, so things
could have been a lot worse.

Thanks again.

Bob

"**THE-RFI-EMI-GUY**" wrote in message
...
Bob; You work at Lucent and can't get this info? No wonder my stock went
from $37 to $2.84!



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Bond all grounds together? Minnie Bannister Home Repair 23 March 16th 04 06:31 PM
Telephone Line 1/ 2 barry martin Home Repair 0 March 8th 04 07:49 PM
Telephone Line Problems barry martin Home Repair 1 March 7th 04 03:00 AM
Burned out electric service line Karl Townsend Metalworking 13 February 18th 04 12:56 AM
Too many devices on telephone line Morgan Home Repair 8 July 1st 03 12:54 AM


All times are GMT +1. The time now is 05:31 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"