GFCI outlets in kitchen
I am replacing my outlets in the kitchen to GFCI (w/stainless steel
countertops I thought it might be a good idea...). I know 20A GFCI outlets are now code in kitchens. Can anyone tell me if the outlets serving the microwave (above stove, plugged in inside cabinet), fridge and stove need to be GFCI outlets? These outlets will be used exclusively for these appliances, and will not be accessible via the countertop. Thanks. |
#2
|
|||
|
|||
chester wrote:
I am replacing my outlets in the kitchen to GFCI (w/stainless steel countertops I thought it might be a good idea...). I know 20A GFCI outlets are now code in kitchens. Can anyone tell me if the outlets serving the microwave (above stove, plugged in inside cabinet), fridge and stove need to be GFCI outlets? These outlets will be used exclusively for these appliances, and will not be accessible via the countertop. Thanks. I have read that it is now allowed by code to replace non-grounded outlets with GFCI three prong outlets. I have am outlet behide the fridge that is a two prong (20A). I was considering bringing in a ground wire, but it would be a considerable hassle. Would it be OK to plug in my fridge to a GFCI outlet that does not have a ground? Seems any current leakage problems would be solved by the GFCI, but is there a quality issue that necessitates a ground when operating the fridge? thx |
#3
|
|||
|
|||
In article , chester wrote:
I have read that it is now allowed by code to replace non-grounded outlets with GFCI three prong outlets. I have am outlet behide the fridge that is a two prong (20A). I was considering bringing in a ground wire, but it would be a considerable hassle. Would it be OK to plug in my fridge to a GFCI outlet that does not have a ground? Seems any current leakage problems would be solved by the GFCI, but is there a quality issue that necessitates a ground when operating the fridge? thx NOT a good idea. If the GFCI trips, what happens to your food? -- Regards, Doug Miller (alphageek at milmac dot com) Nobody ever left footprints in the sands of time by sitting on his butt. And who wants to leave buttprints in the sands of time? |
#4
|
|||
|
|||
Only countertop outlets in the kitchen are required to be GFCI
"Doug Miller" wrote in message om... In article , chester wrote: I have read that it is now allowed by code to replace non-grounded outlets with GFCI three prong outlets. I have am outlet behide the fridge that is a two prong (20A). I was considering bringing in a ground wire, but it would be a considerable hassle. Would it be OK to plug in my fridge to a GFCI outlet that does not have a ground? Seems any current leakage problems would be solved by the GFCI, but is there a quality issue that necessitates a ground when operating the fridge? thx NOT a good idea. If the GFCI trips, what happens to your food? -- Regards, Doug Miller (alphageek at milmac dot com) Nobody ever left footprints in the sands of time by sitting on his butt. And who wants to leave buttprints in the sands of time? |
#5
|
|||
|
|||
A Gfi tripped on my frige so I removed it , it is common I have heard,
plus your food can spoil. It not recommended on the frige. A microwave is well insulated I dont see it as necessary. |
#6
|
|||
|
|||
The fact that the refrigerator outlet is not a grounding type, doesn't
necessarily mean that there isn't a ground present. If the cable type is AC (BX) armored cable you have a ground and just need to attach a ground wire from the box to a grounded outlet "Doug Miller" wrote in message om... In article , chester wrote: I have read that it is now allowed by code to replace non-grounded outlets with GFCI three prong outlets. I have am outlet behide the fridge that is a two prong (20A). I was considering bringing in a ground wire, but it would be a considerable hassle. Would it be OK to plug in my fridge to a GFCI outlet that does not have a ground? Seems any current leakage problems would be solved by the GFCI, but is there a quality issue that necessitates a ground when operating the fridge? thx NOT a good idea. If the GFCI trips, what happens to your food? -- Regards, Doug Miller (alphageek at milmac dot com) Nobody ever left footprints in the sands of time by sitting on his butt. And who wants to leave buttprints in the sands of time? |
#7
|
|||
|
|||
Do not put a GFCI in for your refrigerator. It is not required by code
for a refrigerator, and not recommended for any appliance. |
#8
|
|||
|
|||
Do not put a GFCI in for your refrigerator. It is not required by code
for a refrigerator, and not recommended for any appliance. |
#9
|
|||
|
|||
wrote in message oups.com... Do not put a GFCI in for your refrigerator. It is not required by code for a refrigerator, and not recommended for any appliance. Firstly one needs to remember why GFCI outlets are required in certain areas in the first place. That is for protection from some appliance or other electrical device that is plugged into the GFCI plug if that appliance happens to fall into a sink full of water. Having said that, I don't believe a refrigerator is in any danger of falling into a sink full of water. Plugs on countertops on either side of the sink should be GFCI, even if not required by code. But you MUST do the minimum code requirements. GFCI plugs in other areas that do not have a viable possibility of coming in contact with water either from rain or from a sink do not need to be there. B |
#10
|
|||
|
|||
I have read that it is now allowed by code to replace non-grounded outlets with GFCI three prong outlets. I have am outlet behide the fridge that is a two prong (20A). I was considering bringing in a ground wire, but it would be a considerable hassle. Would it be OK to plug in my fridge to a GFCI outlet that does not have a ground? Seems any SInce nobody else has mentioned it yet, if you put in a GFCI on a non-grounded circut, you are required to label the receptical "no equipment ground", or something like that. |
#11
|
|||
|
|||
On Wed, 02 Mar 2005 21:17:39 -0800, chester
wrote: I am replacing my outlets in the kitchen to GFCI (w/stainless steel countertops I thought it might be a good idea...). I know 20A GFCI Actually the branch feeders only have to be 20A, and the GFCI's can be 15A(with 20A) passthru. outlets are now code in kitchens. Can anyone tell me if the outlets serving the microwave (above stove, plugged in inside cabinet), fridge and stove need to be GFCI outlets? These outlets will be used exclusively for these appliances, and will not be accessible via the countertop. Thanks. I recall the code saying if you have outlets not serving the counter top, having dedicated loads(refridge, etc), and aren't readily accessible, then you can omitt the gfci requirement. In no way take this as fact, you need to reference the code, and find out if your local authority inacted further restrictions. hth, tom @ www.WorkAtHomePlans.com |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Elec info needed 20A circuits | Home Repair | |||
Celebrity Kitchen Design? | Woodworking | |||
kitchen electric | Home Repair | |||
GFCI outlets vs. GFCI breakers? | Home Repair | |||
Planit Millennium II [2 CDs] new !, and other Kitchen Design 3D programscheap software for fitted kitchen design | Woodworking |