Default Re-wiring my dust collector

I am in the process of re-wiring my garage to add 220 for a new table
saw. While I am at it I am wondering if I should re-wire my Penn State
1 1/2 hp dust collector for 220v operation. It is on a shared 110 v
line now which I could wire as a dedicated 110 volt breaker handling
only the collector. If it is on a dedicated 110v breaker of sufficent
amperage is there any real advantage to changing it to 220 operation?

  #2   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 2,047
Default Re-wiring my dust collector

Bob wrote:
I am in the process of re-wiring my garage to add 220 for a new table
saw. While I am at it I am wondering if I should re-wire my Penn State
1 1/2 hp dust collector for 220v operation.


As a matter of practice, use the highest voltage available.

It reduces line losses, thus saving you money.

Lew
  #3   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 25
Default Re-wiring my dust collector

Bob wrote:
I am in the process of re-wiring my garage to add 220 for a new table
saw. While I am at it I am wondering if I should re-wire my Penn State
1 1/2 hp dust collector for 220v operation. It is on a shared 110 v
line now which I could wire as a dedicated 110 volt breaker handling
only the collector. If it is on a dedicated 110v breaker of sufficent
amperage is there any real advantage to changing it to 220 operation?

it will run cooler thus last longer
  #4   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 336
Default Re-wiring my dust collector


Bob wrote:
a dedicated 110v breaker of sufficent
amperage is there any real advantage to changing it to 220 operation?


Bob

Listen and observe carefully when it starts up and runs on 110. Then
wire it for 220 and compare the results. The you will be sold on 220.

Bob AZ

  #5   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 1,617
Default Re-wiring my dust collector


"Bob" wrote in message
oups.com...
I am in the process of re-wiring my garage to add 220 for a new table
saw. While I am at it I am wondering if I should re-wire my Penn State
1 1/2 hp dust collector for 220v operation. It is on a shared 110 v
line now which I could wire as a dedicated 110 volt breaker handling
only the collector. If it is on a dedicated 110v breaker of sufficent
amperage is there any real advantage to changing it to 220 operation?

Measure the current before bothering. My PSI "1 1/2hp" DC only drew 8 amps
on 120v, so there was no reason to rewire it.
A real 1.5hp motor will draw 16a and will really benefit from being on 240v.
Voltage drop will be reduced and the motor will last longer since it will
not be starved on startup.




  #6   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 1,489
Default Re-wiring my dust collector

On 1 Aug 2006 20:24:56 -0700, "Bob" wrote:

I am in the process of re-wiring my garage to add 220 for a new table
saw. While I am at it I am wondering if I should re-wire my Penn State
1 1/2 hp dust collector for 220v operation. It is on a shared 110 v
line now which I could wire as a dedicated 110 volt breaker handling
only the collector. If it is on a dedicated 110v breaker of sufficent
amperage is there any real advantage to changing it to 220 operation?



I re-wired my PennState DC and bought a 220v LongRanger remote with no
regrets. Higher voltage gives smoother motor starts, slightly more
efficient operation.
  #7   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 12
Default Re-wiring my dust collector

Dust collectors draw a lot of currrent during startup (typically
something like 50-60A at 120V). Running at 240V will cut the current
draw in half, which is generally a good thing, but don't expect to
notice a difference in steady-state performance.

If you want to be scientific about it, measure the line voltage at the
dust collector receptacle during startup and running. As long as the
voltage stays at 110V or above, you're fine as is. If it's sagging
below 110V, changing to 240V would be useful.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
"Wood" dust collector for metal dust? Alex Metalworking 11 February 7th 06 03:03 AM
220 wiring question for saw & dust collector LRod Woodworking 61 August 25th 04 06:34 AM
Dust collector woo's Art Woodworking 17 April 21st 04 12:45 AM
Recommend Ducting For JET 1.5 HP Canister Dust Collector Jay Chan Woodworking 2 March 12th 04 08:22 PM
Dust Collection Bob Davis Woodworking 13 January 3rd 04 10:38 PM


All times are GMT +1. The time now is 01:29 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"