UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Graham Jones
 
Posts: n/a
Default Socket hieght, 450mm new build only?

Dos the 450mm minimum socket height from floor level apply only to new
builds? I would like to add new sockets in my house at the same level as
existing ones, approx 300mm. Is this allowed?

Thanks,

Graham
  #2   Report Post  
Lobster
 
Posts: n/a
Default

Graham Jones wrote:
Dos the 450mm minimum socket height from floor level apply only to new
builds? I would like to add new sockets in my house at the same level as
existing ones, approx 300mm. Is this allowed?


I was told 'yes' when I asked this here a few months back, and proceeded
accordingly; certainly the BCO had no comment to make when he visited.

David
  #3   Report Post  
Andrew Gabriel
 
Posts: n/a
Default

In article ,
Lobster writes:
Graham Jones wrote:
Dos the 450mm minimum socket height from floor level apply only to new
builds? I would like to add new sockets in my house at the same level as
existing ones, approx 300mm. Is this allowed?


I was told 'yes' when I asked this here a few months back, and proceeded
accordingly; certainly the BCO had no comment to make when he visited.


Yes. This comes from Part M of the building regs, and only applies
to new buildings, and not even to extensions to existing buildings
(unless the existing building is already Part M compliant).

--
Andrew Gabriel
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Moving socket - options and regulations Graham Jones UK diy 3 March 2nd 05 04:55 PM
Teaching kids how to build skateboards using Vacuum Bagging technique Ted Hunter Woodworking 0 May 31st 04 09:23 PM
Moving BT master socket, is this frowned upon? Jason Arthurs UK diy 48 February 28th 04 09:46 AM
lamp socket mounting sizes (not bulb size) Ben Home Repair 2 December 30th 03 07:09 PM
Question regarding adding an extra socket to the ring main Fiona Reid UK diy 10 September 3rd 03 04:45 PM