#1
![]() |
|||
|
|||
![]()
In message . com,
Gareth writes I had a Worcester 24i combi boiler installed about 18 months ago, and it's been fine since then. Obviously I've not been using the radiators for the last few months, but I've been regularly using hot water with no problem at all. However, this week, I started up my central heating, and noticed that one of my radiators was cooler at the top than bottom, so just bled it a bit to get the heat even. Thought no more of it. Then a couple of days later, I start up the heating, and nothing. It doesn't light, and I can't get hot water either when I turn on my taps. At this point I also noticed that the water pressure level had dropped right off, so I added more water in to get pressure back up to 1 bar. Then realised that the reason I couldn't get it to light was because the cut-off switch had popped up, so pressed that down, and then everything seemed okay. But now whenever I try to start up the heating, within a couple of minutes, the pump's making quite a noise, and then the cut-out switch trips again. However, it does appear that I can get hot water out of the taps with no problem. You don't say what sort of noise Is it air in the system or a rattling noise If it's a rattling noise, it could be that the impeller has broken off the shaft in which case it will make rattling noises and not circulate the water through the central heating system. It also means that as the water isn't circulating, the water in the heat exchanger will overheat and trip the overheat stat How simple a task it is will depend on whether you have isolating valves each side of the pump. If you don't you'll probably have to drain the system, otherwise you can isolate it and remove the body of the pump from the head -normally by undoing the four (6mm?) Allen screws which hold the two pieces together. The information contained in this post may not be published in, or used by http://www.diyprojects.info -- geoff |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Near death boiler + replacing a boiler | UK diy | |||
Combi boiler thermostat not working properly | UK diy | |||
Hot water problem with my combi boiler | UK diy | |||
Boiler problem - hot water, cold radiators | UK diy | |||
Worcester combi boiler not always firing | UK diy |