UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,270
Default Speedfit to cap gas?

Someone has written 'gas pipe under floorboard' on the upstairs wall.
You pull the board up and there it is, with a speedfit cap on.

That can't be OK, can it? Or can it?
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 355
Default Speedfit to cap gas?

On 01/02/2019 20:07, R D S wrote:
Someone has written 'gas pipe under floorboard' on the upstairs wall.
You pull the board up and there it is, with a speedfit cap on.

That can't be OK, can it? Or can it?


No.

--
Email does not work
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 10,998
Default Speedfit to cap gas?

Depends whether its still connected to a supply I guess.
Brian

--
----- --
This newsgroup posting comes to you directly from...
The Sofa of Brian Gaff...

Blind user, so no pictures please
Note this Signature is meaningless.!
"Tim Watts" wrote in message
...
On 01/02/2019 20:07, R D S wrote:
Someone has written 'gas pipe under floorboard' on the upstairs wall. You
pull the board up and there it is, with a speedfit cap on.

That can't be OK, can it? Or can it?


No.

--
Email does not work



  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 8,019
Default Speedfit to cap gas?

On 01/02/2019 20:20, Tim Watts wrote:
On 01/02/2019 20:07, R D S wrote:
Someone has written 'gas pipe under floorboard' on the upstairs wall.
You pull the board up and there it is, with a speedfit cap on.

That can't be OK, can it? Or can it?


No.

It's certainly not ideal, but the standard cooker bayonet fitting relies
on O rings to seal as well.

Best, obviously, is a soldered on cap. How about a copper push fit? I
have always found them pretty secure.

Compression fitting? Allowed on gas fires.

Taper threads with PTFE? Fibre plus sealant? (Still needs soldering,
obviously).
  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 7,829
Default Speedfit to cap gas?

newshound wrote:

Tim Watts wrote:

R D S wrote:

Someone has written 'gas pipe under floorboard' on the upstairs wall.
You pull the board up and there it is, with a speedfit cap on.
That can't be OK, can it? Or can it?


No.


How about a copper push fit?


Not allowed either.

https://gasproducts.co.uk/plumbing/tectite-sprint-push-fit-fittings/tectite-sprint-push-fit-15mm-stop-end.html

"These fittings are WRAS approved products and must be used for water only."

Makes you wonder why a company called Hamilton Gas Products stocks them...


  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25,191
Default Speedfit to cap gas?

On 01/02/2019 20:07, R D S wrote:
Someone has written 'gas pipe under floorboard' on the upstairs wall.
You pull the board up and there it is, with a speedfit cap on.

That can't be OK, can it? Or can it?


Its not considered and appropriate fitting for gas. Will it leak?
probably not. However its performance in a fire would be very poor.

Compression stop end, or solder fitting stop end would be the fittings
of choice.



--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
  #7   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 355
Default Speedfit to cap gas?

On 02/02/2019 09:02, newshound wrote:
On 01/02/2019 20:20, Tim Watts wrote:
On 01/02/2019 20:07, R D S wrote:
Someone has written 'gas pipe under floorboard' on the upstairs wall.
You pull the board up and there it is, with a speedfit cap on.

That can't be OK, can it? Or can it?


No.

It's certainly not ideal, but the standard cooker bayonet fitting relies
on O rings to seal as well.


I think you'll find in the gas regs that it's positively verboten, not
"not ideal".

The only place plastic pipes (and indirectly, fittings) are permitted in
outdoors as in the main supply. And cooker hoses, and as you say, the
bayonet connector - but those are specifically regulated.


Best, obviously, is a soldered on cap. How about a copper push fit? I
have always found them pretty secure.


No.

Compression fitting? Allowed on gas fires.


If accessible, yes. I'm not 100% sure if "under an accessible floor" is
prohibited though - I default to "only soldered copper or iron under
floors etc".



--
Email does not work
  #8   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 11,175
Default Speedfit to cap gas?

In article ,
Tim Watts writes:
On 02/02/2019 09:02, newshound wrote:
On 01/02/2019 20:20, Tim Watts wrote:
On 01/02/2019 20:07, R D S wrote:
Someone has written 'gas pipe under floorboard' on the upstairs wall.
You pull the board up and there it is, with a speedfit cap on.

That can't be OK, can it? Or can it?

No.

It's certainly not ideal, but the standard cooker bayonet fitting relies
on O rings to seal as well.


I think you'll find in the gas regs that it's positively verboten, not
"not ideal".

The only place plastic pipes (and indirectly, fittings) are permitted in
outdoors as in the main supply. And cooker hoses, and as you say, the
bayonet connector - but those are specifically regulated.


Cooker hoses are stainless steel hoses, with a rubber covering.
Rubber hoses are not permitted (even though bunsen burners have them;-).

Anaconda (flexible) pipes are also popular with installers who need to
route 28mm (equivalent) pipe through convoluted places. They are also
stainless steel hoses but with a PVC covering and special termination
fittings. Very expensive, unless you are paying for an installer's time.

Best, obviously, is a soldered on cap. How about a copper push fit? I
have always found them pretty secure.


No.

Compression fitting? Allowed on gas fires.


If accessible, yes. I'm not 100% sure if "under an accessible floor" is
prohibited though - I default to "only soldered copper or iron under
floors etc".


Compression are not allowed under a floor. I'm not sure it's just an
access issue, but also the possibility of a tiny leak in a confined
space. There are also requirements on venting compartments of certain
sizes containing gas pipes.

--
Andrew Gabriel
[email address is not usable -- followup in the newsgroup]
  #9   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 8,019
Default Speedfit to cap gas?

On 02/02/2019 10:40, Tim Watts wrote:
On 02/02/2019 09:02, newshound wrote:
On 01/02/2019 20:20, Tim Watts wrote:
On 01/02/2019 20:07, R D S wrote:
Someone has written 'gas pipe under floorboard' on the upstairs
wall. You pull the board up and there it is, with a speedfit cap on.

That can't be OK, can it? Or can it?

No.

It's certainly not ideal, but the standard cooker bayonet fitting
relies on O rings to seal as well.


I think you'll find in the gas regs that it's positively verboten, not
"not ideal".

The only place plastic pipes (and indirectly, fittings) are permitted in
outdoors as in the main supply. And cooker hoses, and as you say, the
bayonet connector - but those are specifically regulated.

Sorry, I wasn't trying to imply they were legal, just that having
discovered it the risk is not particularly severe. So, for example, if
there was an opportunity to disconnect the run at the "source" and cap
it off in (say) a month, then I would leave it rather than trying a
legal fix. A "time at risk" argument.

Perhaps the bayonet connector has viton O-rings which have better high
temperature performance than nitrile.



Best, obviously, is a soldered on cap. How about a copper push fit? I
have always found them pretty secure.


No.

Compression fitting? Allowed on gas fires.


If accessible, yes. I'm not 100% sure if "under an accessible floor" is
prohibited though - I default to "only soldered copper or iron under
floors etc".



No dispute there!

  #10   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 7,829
Default Speedfit to cap gas?

Andrew Gabriel wrote:

Anaconda (flexible) pipes are also popular with installers who need to
route 28mm (equivalent) pipe through convoluted places. They are also
stainless steel hoses but with a PVC covering and special termination
fittings. Very expensive


When re-fitting parents kitchen recently, they'd previously had
free-standing gas cooker, now gas hob and built-in waist height fan
oven, so the old bayonet went and rather than having to work out exactly
where to position rigid pipework for connecting the hob, used one of these

https://screwfix.com/p/hobflex/5802v

Just fix a stub of 15mm pipe pointing downwards in approximate position,
then the anaconda droops down and loops back up to screw into the hob,
very easy.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Natural Gas - Pictures and Diagrams of Natural Gas, Natural Gas Furnace, Natural Gas Grill, Natural Gas Heater, Natural Gas Water Heater and Natural Gas Vehicle [email protected] Home Ownership 3 June 18th 07 06:34 AM
Natural Gas - Pictures and Diagrams of Natural Gas, Natural Gas Furnace, Natural Gas Grill, Natural Gas Heater, Natural Gas Water Heater and Natural Gas Vehicle [email protected] Home Repair 1 June 18th 07 05:32 AM
High cap gutters with (apparently) low cap downpipes?? Richard UK diy 5 December 19th 04 08:08 PM
I LOVE Speedfit! David W.E. Roberts UK diy 53 August 14th 03 05:05 PM