Hi All
Can you spot the errors made by putting this sewing machine out for sale in a charity shop? - 13 amp plug with unsleeved L and N pins - figure-8 single-insulated wire outside the machine casing to the lampholder - unguarded drive belt and pulleys between the motor and the machine* Not this exact machine, but this sort of arrangement, see photo 11 https://www.ebth.com/items/6178614-r...sewing-machine Owain -- Please help keep the uk.telecom archive available on Google https://productforums.google.com/for...ps/M6Cs9XdH-2o |
#3
Posted to uk.d-i-y
|
|||
|
|||
PAT Testing and consumer safety regulations
On Wednesday, 1 August 2018 17:40:06 UTC+1, Brian Gaff wrote:
wrote in message ... Hi All Can you spot the errors made by putting this sewing machine out for sale in a charity shop? - 13 amp plug with unsleeved L and N pins - figure-8 single-insulated wire outside the machine casing to the lampholder - unguarded drive belt and pulleys between the motor and the machine* Not this exact machine, but this sort of arrangement, see photo 11 https://www.ebth.com/items/6178614-r...sewing-machine Owain Unsleeved plug & single insulated flex are PAT fails of course. The drive belt I don't believe has enough force or momentum to cause injury, so not a problem. And not an electrical issue anyway. If its an antique, one must cut the plug off and make sure you have a sheet that goes with it about it not complying with modern safety standards if actually powered up. This sort of thing will mean a heck of a lot of old kit that people might like to collect ends up as landfill, sadly. Brian not true of course NT |
#4
Posted to uk.d-i-y
|
|||
|
|||
PAT Testing and consumer safety regulations
In article ,
writes: On Wednesday, 1 August 2018 17:40:06 UTC+1, Brian Gaff wrote: wrote in message ... Hi All Can you spot the errors made by putting this sewing machine out for sale in a charity shop? - 13 amp plug with unsleeved L and N pins - figure-8 single-insulated wire outside the machine casing to the lampholder - unguarded drive belt and pulleys between the motor and the machine* Not this exact machine, but this sort of arrangement, see photo 11 https://www.ebth.com/items/6178614-r...sewing-machine Well, that's not for the UK market, so unsurprisingly it doesn't conform to UK/EU appliance safety rules. Unsleeved plug & single insulated flex are PAT fails of course. Unsleaved plug is not a PAT fail in itself. However, it is illegal to sell such an appliance under the Plugs and Sockets (Safety) Regulations (even at a fair or car boot sale). When performing a PAT test, the owner should be advised of this. If the PAT test is specifically to ensure the item is suitable for sale, then obviously it isn't. The drive belt I don't believe has enough force or momentum to cause injury, so not a problem. And not an electrical issue anyway. If its an antique, one must cut the plug off and make sure you have a sheet that goes with it about it not complying with modern safety standards if actually powered up. This sort of thing will mean a heck of a lot of old kit that people might like to collect ends up as landfill, sadly. Brian not true of course He's spot on. You can sell something as an antique which would be dangerous to use, providing the buyer is made aware and it's supplied in a condition where it can't be put back into service without the use of tools. Supplying without a plug is a common way to meet this. -- Andrew Gabriel [email address is not usable -- followup in the newsgroup] |
#5
Posted to uk.d-i-y
|
|||
|
|||
PAT Testing and consumer safety regulations
On Wednesday, 1 August 2018 20:44:20 UTC+1, Andrew Gabriel wrote:
In article , tabbypurr writes: On Wednesday, 1 August 2018 17:40:06 UTC+1, Brian Gaff wrote: wrote in message ... Hi All Can you spot the errors made by putting this sewing machine out for sale in a charity shop? - 13 amp plug with unsleeved L and N pins - figure-8 single-insulated wire outside the machine casing to the lampholder - unguarded drive belt and pulleys between the motor and the machine* Not this exact machine, but this sort of arrangement, see photo 11 https://www.ebth.com/items/6178614-r...sewing-machine Well, that's not for the UK market, so unsurprisingly it doesn't conform to UK/EU appliance safety rules. Unsleeved plug & single insulated flex are PAT fails of course. Unsleaved plug is not a PAT fail in itself. However, it is illegal to sell such an appliance under the Plugs and Sockets (Safety) Regulations (even at a fair or car boot sale). When performing a PAT test, the owner should be advised of this. If the PAT test is specifically to ensure the item is suitable for sale, then obviously it isn't. The drive belt I don't believe has enough force or momentum to cause injury, so not a problem. And not an electrical issue anyway. If its an antique, one must cut the plug off and make sure you have a sheet that goes with it about it not complying with modern safety standards if actually powered up. This sort of thing will mean a heck of a lot of old kit that people might like to collect ends up as landfill, sadly. Brian not true of course He's spot on. Not at all, lots of antique electrical kit passes current PAT tests. And lots doesn't. You can sell something as an antique which would be dangerous to use, providing the buyer is made aware and it's supplied in a condition where it can't be put back into service without the use of tools. Supplying without a plug is a common way to meet this. I don't believe that supply without a plug makes it legal. It directly contravenes the Act. NT |
#6
Posted to uk.d-i-y
|
|||
|
|||
PAT Testing and consumer safety regulations
Yes it does end up as landfill, I spoke to the bloke at the tip, apparently
collectors regularly want to see what has come in in case its valuable. Increasingly old radios and sewing machines are collectable by those with the space and the inclination. What next, Old lawn mowers perhaps? Maybe its different out in the sticks. If you mean the bit about illegal to sell. The info I gave came from trading standards 2 years ago, when I wanted to sell a vintage granite table lamp with single insulated flex. Its not illegal to own it and to own it you had to have bought it, but all provision has to be made to stop anyone else using it in the condition which does not comply with current regulations. I bet there are houses still running that have old rubber covered wiring in them, and its only when it goes phut anyone bothers to worry. Brian -- ----- -- This newsgroup posting comes to you directly from... The Sofa of Brian Gaff... Blind user, so no pictures please Note this Signature is meaningless.! wrote in message ... On Wednesday, 1 August 2018 17:40:06 UTC+1, Brian Gaff wrote: wrote in message ... Hi All Can you spot the errors made by putting this sewing machine out for sale in a charity shop? - 13 amp plug with unsleeved L and N pins - figure-8 single-insulated wire outside the machine casing to the lampholder - unguarded drive belt and pulleys between the motor and the machine* Not this exact machine, but this sort of arrangement, see photo 11 https://www.ebth.com/items/6178614-r...sewing-machine Owain Unsleeved plug & single insulated flex are PAT fails of course. The drive belt I don't believe has enough force or momentum to cause injury, so not a problem. And not an electrical issue anyway. If its an antique, one must cut the plug off and make sure you have a sheet that goes with it about it not complying with modern safety standards if actually powered up. This sort of thing will mean a heck of a lot of old kit that people might like to collect ends up as landfill, sadly. Brian not true of course NT |
#7
Posted to uk.d-i-y
|
|||
|
|||
PAT Testing and consumer safety regulations
On Wed, 1 Aug 2018 09:36:16 -0700 (PDT),
wrote: Hi All Can you spot the errors made by putting this sewing machine out for sale in a charity shop? - 13 amp plug with unsleeved L and N pins No I cannot see the plug. However, if it is for sale at $35 I assume it is US 110V. I do not know whether sleeved pins are required. Perhaps you could enlighten us. - figure-8 single-insulated wire outside the machine casing to the lampholder Not sure what this means but are wires usually insulated more than once? - unguarded drive belt and pulleys between the motor and the machine* It is advertised as a 'vintage' machine so were it not authentic I think there would be a bigger issue in terms of confirmity to description. Not this exact machine, but this sort of arrangement, see photo 11 https://www.ebth.com/items/6178614-r...sewing-machine Owain |
#8
Posted to uk.d-i-y
|
|||
|
|||
PAT Testing and consumer safety regulations
On Wednesday, 1 August 2018 17:36:18 UTC+1, wrote:
Not this exact machine, but this sort of arrangement, see photo 11 https://www.ebth.com/items/6178614-r...sewing-machine As some people may have misunderstood me, the picture illustrates the general arrangement of motor and drive belt, not the actual machine in question. And it's displayed with a helpful notice saying "sewing machine - full working order", not an an antique for display purposes. I'm certainly not volunteering to stick my finger anywhere near the motor. Owain -- Please help keep the uk.telecom archive available on Google https://productforums.google.com/for...ps/M6Cs9XdH-2o |
#9
Posted to uk.d-i-y
|
|||
|
|||
PAT Testing and consumer safety regulations
Hi All
Can you spot the errors made by putting this sewing machine out for sale in a charity shop? - 13 amp plug with unsleeved L and N pins - figure-8 single-insulated wire outside the machine casing to the lampholder - unguarded drive belt and pulleys between the motor and the machine* Not this exact machine, but this sort of arrangement, see photo 11 https://www.ebth.com/items/6178614-r...sewing-machine Owain Perhaps it was a venerable Singer 99K like we have? It belonged to SWMBO's grandmother and spent 50 years in my late MiL's cellar until I rescued. It has twin flex to the plug and the foot pedal (the later has no exposed metal) the flex is double insulated. The plug is an old MK with no sleeving on the pins. I am in no hurry to replace that. I suppose I should really fit a three core mains led and earth the machine, perhaps I'll get round tuit. Oh, top for anyone with a 99K. I was using it on Monday, and left it plugged in for half an hour while I went outside. When I returned the machine was operating at about half speed, "stitching its own thread". A little investigation showed that the interference filter capacitor across the rheostat in the foot pedal was reading 50 ohms. I snipped it out. -- Graham. %Profound_observation% |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
PAT / safety-testing - domestic lighting? | UK diy | |||
PAT testing appliances in an office environment is a total waste of time money and effort. | UK diy | |||
Letting a house and PAT testing | UK diy | |||
Consumer Product Safety Comm. to discuss proposed SawStop technology safety rule | Woodworking | |||
PAT Testing costs | UK diy |