Hi All

Can you spot the errors made by putting this sewing machine out for sale in a charity shop?

- 13 amp plug with unsleeved L and N pins
- figure-8 single-insulated wire outside the machine casing to the lampholder
- unguarded drive belt and pulleys between the motor and the machine*

Not this exact machine, but this sort of arrangement, see photo 11
https://www.ebth.com/items/6178614-r...sewing-machine

Owain

--

Please help keep the uk.telecom archive available on Google
https://productforums.google.com/for...ps/M6Cs9XdH-2o

  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 10,998
Default PAT Testing and consumer safety regulations

If its an antique, one must cut the plug off and make sure you have a sheet
that goes with it about it not complying with modern safety standards if
actually powered up.

This sort of thing will mean a heck of a lot of old kit that people might
like to collect ends up as landfill, sadly.
Brian

--
----- --
This newsgroup posting comes to you directly from...
The Sofa of Brian Gaff...

Blind user, so no pictures please
Note this Signature is meaningless.!
wrote in message
...
Hi All

Can you spot the errors made by putting this sewing machine out for sale
in a charity shop?

- 13 amp plug with unsleeved L and N pins
- figure-8 single-insulated wire outside the machine casing to the
lampholder
- unguarded drive belt and pulleys between the motor and the machine*

Not this exact machine, but this sort of arrangement, see photo 11
https://www.ebth.com/items/6178614-r...sewing-machine

Owain

--

Please help keep the uk.telecom archive available on Google
https://productforums.google.com/for...ps/M6Cs9XdH-2o



  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 12,364
Default PAT Testing and consumer safety regulations

On Wednesday, 1 August 2018 17:40:06 UTC+1, Brian Gaff wrote:
wrote in message
...


Hi All

Can you spot the errors made by putting this sewing machine out for sale
in a charity shop?

- 13 amp plug with unsleeved L and N pins
- figure-8 single-insulated wire outside the machine casing to the
lampholder
- unguarded drive belt and pulleys between the motor and the machine*

Not this exact machine, but this sort of arrangement, see photo 11
https://www.ebth.com/items/6178614-r...sewing-machine

Owain


Unsleeved plug & single insulated flex are PAT fails of course.

The drive belt I don't believe has enough force or momentum to cause injury, so not a problem. And not an electrical issue anyway.


If its an antique, one must cut the plug off and make sure you have a sheet
that goes with it about it not complying with modern safety standards if
actually powered up.

This sort of thing will mean a heck of a lot of old kit that people might
like to collect ends up as landfill, sadly.
Brian


not true of course


NT
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 11,175
Default PAT Testing and consumer safety regulations

In article ,
writes:
On Wednesday, 1 August 2018 17:40:06 UTC+1, Brian Gaff wrote:
wrote in message
...


Hi All

Can you spot the errors made by putting this sewing machine out for sale
in a charity shop?

- 13 amp plug with unsleeved L and N pins
- figure-8 single-insulated wire outside the machine casing to the
lampholder
- unguarded drive belt and pulleys between the motor and the machine*

Not this exact machine, but this sort of arrangement, see photo 11
https://www.ebth.com/items/6178614-r...sewing-machine

Well, that's not for the UK market, so unsurprisingly it doesn't
conform to UK/EU appliance safety rules.

Unsleeved plug & single insulated flex are PAT fails of course.


Unsleaved plug is not a PAT fail in itself. However, it is illegal
to sell such an appliance under the Plugs and Sockets (Safety)
Regulations (even at a fair or car boot sale). When performing a
PAT test, the owner should be advised of this. If the PAT test is
specifically to ensure the item is suitable for sale, then obviously
it isn't.

The drive belt I don't believe has enough force or momentum to cause injury, so not a problem. And not an electrical issue anyway.


If its an antique, one must cut the plug off and make sure you have a sheet
that goes with it about it not complying with modern safety standards if
actually powered up.

This sort of thing will mean a heck of a lot of old kit that people might
like to collect ends up as landfill, sadly.
Brian


not true of course


He's spot on. You can sell something as an antique which would be
dangerous to use, providing the buyer is made aware and it's supplied
in a condition where it can't be put back into service without the
use of tools. Supplying without a plug is a common way to meet this.

--
Andrew Gabriel
[email address is not usable -- followup in the newsgroup]
  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 12,364
Default PAT Testing and consumer safety regulations

On Wednesday, 1 August 2018 20:44:20 UTC+1, Andrew Gabriel wrote:
In article ,
tabbypurr writes:
On Wednesday, 1 August 2018 17:40:06 UTC+1, Brian Gaff wrote:
wrote in message
...


Hi All

Can you spot the errors made by putting this sewing machine out for sale
in a charity shop?

- 13 amp plug with unsleeved L and N pins
- figure-8 single-insulated wire outside the machine casing to the
lampholder
- unguarded drive belt and pulleys between the motor and the machine*

Not this exact machine, but this sort of arrangement, see photo 11
https://www.ebth.com/items/6178614-r...sewing-machine


Well, that's not for the UK market, so unsurprisingly it doesn't
conform to UK/EU appliance safety rules.

Unsleeved plug & single insulated flex are PAT fails of course.


Unsleaved plug is not a PAT fail in itself. However, it is illegal
to sell such an appliance under the Plugs and Sockets (Safety)
Regulations (even at a fair or car boot sale). When performing a
PAT test, the owner should be advised of this. If the PAT test is
specifically to ensure the item is suitable for sale, then obviously
it isn't.

The drive belt I don't believe has enough force or momentum to cause injury, so not a problem. And not an electrical issue anyway.


If its an antique, one must cut the plug off and make sure you have a sheet
that goes with it about it not complying with modern safety standards if
actually powered up.

This sort of thing will mean a heck of a lot of old kit that people might
like to collect ends up as landfill, sadly.
Brian


not true of course


He's spot on.


Not at all, lots of antique electrical kit passes current PAT tests. And lots doesn't.


You can sell something as an antique which would be
dangerous to use, providing the buyer is made aware and it's supplied
in a condition where it can't be put back into service without the
use of tools. Supplying without a plug is a common way to meet this.


I don't believe that supply without a plug makes it legal. It directly contravenes the Act.


NT


  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 10,998
Default PAT Testing and consumer safety regulations

Yes it does end up as landfill, I spoke to the bloke at the tip, apparently
collectors regularly want to see what has come in in case its valuable.
Increasingly old radios and sewing machines are collectable by those with
the space and the inclination.
What next, Old lawn mowers perhaps?
Maybe its different out in the sticks.
If you mean the bit about illegal to sell. The info I gave came from
trading standards 2 years ago, when I wanted to sell a vintage granite table
lamp with single insulated flex.
Its not illegal to own it and to own it you had to have bought it, but all
provision has to be made to stop anyone else using it in the condition which
does not comply with current regulations.
I bet there are houses still running that have old rubber covered wiring in
them, and its only when it goes phut anyone bothers to worry.
Brian

--
----- --
This newsgroup posting comes to you directly from...
The Sofa of Brian Gaff...

Blind user, so no pictures please
Note this Signature is meaningless.!
wrote in message
...
On Wednesday, 1 August 2018 17:40:06 UTC+1, Brian Gaff wrote:
wrote in message
...


Hi All

Can you spot the errors made by putting this sewing machine out for
sale
in a charity shop?

- 13 amp plug with unsleeved L and N pins
- figure-8 single-insulated wire outside the machine casing to the
lampholder
- unguarded drive belt and pulleys between the motor and the machine*

Not this exact machine, but this sort of arrangement, see photo 11
https://www.ebth.com/items/6178614-r...sewing-machine

Owain


Unsleeved plug & single insulated flex are PAT fails of course.

The drive belt I don't believe has enough force or momentum to cause
injury, so not a problem. And not an electrical issue anyway.


If its an antique, one must cut the plug off and make sure you have a
sheet
that goes with it about it not complying with modern safety standards if
actually powered up.

This sort of thing will mean a heck of a lot of old kit that people might
like to collect ends up as landfill, sadly.
Brian


not true of course


NT



  #8   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 4,564
Default PAT Testing and consumer safety regulations

On Wednesday, 1 August 2018 17:36:18 UTC+1, wrote:
Not this exact machine, but this sort of arrangement, see photo 11
https://www.ebth.com/items/6178614-r...sewing-machine


As some people may have misunderstood me, the picture illustrates the general arrangement of motor and drive belt, not the actual machine in question.

And it's displayed with a helpful notice saying "sewing machine - full working order", not an an antique for display purposes.

I'm certainly not volunteering to stick my finger anywhere near the motor.

Owain


--
Please help keep the uk.telecom archive available on Google
https://productforums.google.com/for...ps/M6Cs9XdH-2o

  #9   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,105
Default PAT Testing and consumer safety regulations

Hi All

Can you spot the errors made by putting this sewing machine out for sale in a charity shop?

- 13 amp plug with unsleeved L and N pins
- figure-8 single-insulated wire outside the machine casing to the lampholder
- unguarded drive belt and pulleys between the motor and the machine*

Not this exact machine, but this sort of arrangement, see photo 11
https://www.ebth.com/items/6178614-r...sewing-machine

Owain


Perhaps it was a venerable Singer 99K like we have?
It belonged to SWMBO's grandmother and spent 50 years in my late MiL's
cellar until I rescued.
It has twin flex to the plug and the foot pedal (the later has no
exposed metal) the flex is double insulated. The plug is an old MK
with no sleeving on the pins. I am in no hurry to replace that.

I suppose I should really fit a three core mains led and earth the
machine, perhaps I'll get round tuit.

Oh, top for anyone with a 99K.
I was using it on Monday, and left it plugged in for half an hour
while I went outside. When I returned the machine was operating at
about half speed, "stitching its own thread".

A little investigation showed that the interference filter capacitor
across the rheostat in the foot pedal was reading 50 ohms. I snipped
it out.

--

Graham.
%Profound_observation%
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
PAT / safety-testing - domestic lighting? Adrian Brentnall[_2_] UK diy 160 February 9th 18 11:53 PM
PAT testing appliances in an office environment is a total waste of time money and effort. Graham.[_3_] UK diy 20 March 20th 11 06:50 PM
Letting a house and PAT testing F UK diy 4 January 9th 07 06:43 PM
Consumer Product Safety Comm. to discuss proposed SawStop technology safety rule George Max Woodworking 256 September 16th 06 06:03 PM
PAT Testing costs Andy Dingley UK diy 14 November 25th 04 10:53 AM


All times are GMT +1. The time now is 03:05 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"