![]() "Julian" wrote in message ... Hi all I am a complete amateur trying to get my central heating going again. I reattached an old radiator, bled it and all seemed fine then I noticed that the downstairs radiators were all cold. Upstairs were lukwarm all of a sudden. I assumed an airlock but could not find air in any of the rads. Then I looked in the attic and found that header tank was empty (and dry). Fixed valve on stop cock and that seems to be ok now. I ssumed system airlock. We don't seem to have a bleed valve on the system in this house so I drained it down and refilled it bleeding all downstairs and then upstairs. Now when switched central heating on again, the water does not seem to flow and boiler does not fully ignite (pilot only). Can anyone detect anything screamingly obvious that I have neglected to do? Pump is definitely working by the way. Jules Have you bled the pump? Should be a big (plastic?) screw you loosen to let water out. Air in the pump can prevent water circulating. HTH Dave R |
#2
![]() |
|||
|
|||
![]()
In message , David W.E.
Roberts writes Can anyone detect anything screamingly obvious that I have neglected to do? Pump is definitely working by the way. Jules Have you bled the pump? Should be a big (plastic?) screw you loosen to let water out. Air in the pump can prevent water circulating. I hope you're not on about the big chrome screw at the back of the pump. This is not a bleed screw. -- geoff |
#3
![]() |
|||
|
|||
![]()
On Mon, 08 Dec 2003 21:03:34 +0000, geoff wrote:
In message , David W.E. Roberts writes Can anyone detect anything screamingly obvious that I have neglected to do? Pump is definitely working by the way. Jules Have you bled the pump? Should be a big (plastic?) screw you loosen to let water out. Air in the pump can prevent water circulating. I hope you're not on about the big chrome screw at the back of the pump. This is not a bleed screw. OK it's an access cover but it serves to let any air that's in the pump out. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html |
#4
![]() |
|||
|
|||
![]()
In message .uk, Ed
Sirett writes On Mon, 08 Dec 2003 21:03:34 +0000, geoff wrote: In message , David W.E. Roberts writes Can anyone detect anything screamingly obvious that I have neglected to do? Pump is definitely working by the way. Jules Have you bled the pump? Should be a big (plastic?) screw you loosen to let water out. Air in the pump can prevent water circulating. I hope you're not on about the big chrome screw at the back of the pump. This is not a bleed screw. OK it's an access cover but it serves to let any air that's in the pump out. Not if it's mounted horizontally Ed (as in my boiler). Both motor bearings are between the water and the screw cover. -- geoff |
#5
![]() |
|||
|
|||
![]()
On Tue, 09 Dec 2003 00:04:11 +0000, geoff wrote:
In message .uk, Ed Sirett writes On Mon, 08 Dec 2003 21:03:34 +0000, geoff wrote: In message , David W.E. Roberts writes Can anyone detect anything screamingly obvious that I have neglected to do? Pump is definitely working by the way. Jules Have you bled the pump? Should be a big (plastic?) screw you loosen to let water out. Air in the pump can prevent water circulating. I hope you're not on about the big chrome screw at the back of the pump. This is not a bleed screw. OK it's an access cover but it serves to let any air that's in the pump out. Not if it's mounted horizontally Ed (as in my boiler). Both motor bearings are between the water and the screw cover. Perhaps I should have said it serves to let enough of the air out to get the pump primed. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html |
#6
![]() |
|||
|
|||
![]()
It's a grundfos selectric.
Can't see any screw except the big one in the middle which I have removed and replaced to no avail. It spurted out a little water and the pump rotor is visible. Seemed to be spinning happily. Jules "David W.E. Roberts" wrote in message ... "Julian" wrote in message ... Have you bled the pump? Should be a big (plastic?) screw you loosen to let water out. Air in the pump can prevent water circulating. HTH Dave R |
#7
![]() |
|||
|
|||
![]() "Julian" wrote in message ... It's a grundfos selectric. Can't see any screw except the big one in the middle which I have removed and replaced to no avail. It spurted out a little water and the pump rotor is visible. Seemed to be spinning happily. Jules With my pump there is a big black plastic screw in the middle of the cover. If I unscrew this a few turns then jiggle it water comes out. This effectively bleeds the pump. Had to do this last time I drained and refilled because of symptoms like yours - pump running but no heat to radiators. After some jiggling and spurting (plumbing can be fun) the note of the pump changed, there was a 'shoosh' noise, and everything started working again. If your setup is like mine (pump in airing cupboard by hot water tank, higher than highest radiator) then you probably got into the situation where the upstairs radiators had water but the pump was running on air. This can cause an airlock in the feed down from the header tank to the system, and/or in the pump. (1) Try jiggling that central screw a bit more - from what you said you didn't get a lot of water out so you may still have mainly air in the pump. If the pump was full of water and pumping at presssure I would expect water to come out quite forcefully. Also, if you have a speed switch, try increasing the speed of the pump. (2) Try to clear out the feed from your header tank to the system. You can do this from the top or the bottom. (i) from the top: tie up the stop cock and then drain the header tank using whatever drain you have at the bottom of the system. If your header tank will not drain because of an airlock or blockage, then siphon it out into the bath using a hosepipe. This also cleans any crud out of the header tank. Disconnect the feed pipe from the bottom of the tank, and connect a hose pipe to it with a jubilee clip. Other end of the hosepipe on a mains cold tap. This will pressurise the system and then you can bleed all the radiators and hopefully clear all the air out. This is especially effective when gunge has been sucked out of the header tank into the pipework because you let it empty. (ii) from the bottom: attach a hose pipe between a cold mains tap and your drain tap at the bottom of the central heating. Open the drain tap and turn on the cold tap. This will pressurise your system and should drive water up the filler pipe to the header tank, then out the overflow (check carefully first that your overflow is working). This should shift any air out of the top end of the system above the level of the upstairs radiators. Do this slowly and carefully! Too much oomph with the cold mains, or a poorly tightened jubilee clip, can rain on your parade. I would be mildly surprised if you boiler had overheated because the thermostat should shut it off as soon as it is up to temperature, and you haven't been running it dry as far as I can tell because your upstairs radiators were still warm, therfore at least partly full of water. My (virtual) money is still on an airlock in the pump. Cheers Dave R |
#8
![]() |
|||
|
|||
![]()
In an earlier contribution to this discussion,
David W.E. Roberts wrote: (i) from the top: SNIP Disconnect the feed pipe from the bottom of the tank, and connect a hose pipe to it with a jubilee clip. Other end of the hosepipe on a mains cold tap. This will pressurise the system and then you can bleed all the radiators and hopefully clear all the air out. Er.. what about the expansion pipe? Unless I'm missing something(!), rather than pressurise the system, mains water will flow up the expansion pipe into the header tank - and will promptly pee out through the (now open) bottom connection! -- Cheers, Set Square ______ Please reply to newsgroup. Reply address is Black Hole! |
#9
![]() |
|||
|
|||
![]() "Set Square" wrote in message ... In an earlier contribution to this discussion, David W.E. Roberts wrote: (i) from the top: SNIP Disconnect the feed pipe from the bottom of the tank, and connect a hose pipe to it with a jubilee clip. Other end of the hosepipe on a mains cold tap. This will pressurise the system and then you can bleed all the radiators and hopefully clear all the air out. Er.. what about the expansion pipe? Unless I'm missing something(!), rather than pressurise the system, mains water will flow up the expansion pipe into the header tank - and will promptly pee out through the (now open) bottom connection! -- Cheers, Set Square Good point - I am now racking my brains to remeber how I did this when I had to clear my system out. My first guess would be that I put a bung in the hole out of the tank, or a stop end where the copper was disconnected from the tank coupler. However to pressurise the system you would have to close off the expansion pipe as well. Second thought is that I had my trusty helper working the tap, and once water came out of the expansion pipe then the top end of the system was clear of air and crud. Probably best to put a bucket in the (empty) tank under the expansion pipe to save having to siphon the water out again. I describd this correctly (I think) a few months back - will have to Google back and find out. Thinking further, if you attached the hose to the expansion pipe with the down pipe still connected, then this would force water round the system and water should come up the down pipe. This again would clear air and crud out of the top end of the system. However ISTR my expansion pipe is 22mm so would need some adapting to take a hose pipe (which just fits 15mm). Apologies to the OP for my senior moment :-( Cheers Dave R |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Rayburn integrated into central heating | UK diy | |||
Central Heating costs + other questions | UK diy | |||
No central heating - HW only threewayvalve and tank therm | UK diy | |||
Pool water in central heating system | UK diy | |||
Further to my last post entitled 'Flushing and treating central heating question' | UK diy |