Banshee noise from boiler
I've recently moved into a house with a 7 year old Halstead 55 wall mounted
boiler supplying an ordinary tank fed hot water and central heating system. After a while, when it all starts to heat up, the boiler begins to make a wailing type noise which can be heard all through the house. It stops as soon as the boiler stat kills the flame and if you set the stat lower it doesn't happen. The pump seems to be working fine and the problem's worse if it's just heating hot water rather than the rads as well. This implies it's related to either the boiler heat exchanger temperature or the temperature of the return flow. Anyone got any ideas how to fix it or where to start fiddling, I want to turn up the boiler stat to get the rads hotter but at the moment I can't without the kids thinking the house is haunted. TIA Andy R |
#2
|
|||
|
|||
Banshee noise from boiler
Anyone got any ideas how to fix it or where to start fiddling, I
want to turn up the boiler stat to get the rads hotter but at the moment I can't without the kids thinking the house is haunted. It sounds like the boiler is kettling. This is usually because the heat transfer through the boiler exchanger is too low. This could be for a number of reasons. Some suggestions: 1. Pump knackered 2. Pump set too slow 3. Pump valves not open properly 4. Heat exchanger clogged/scaled 5. Most TRVs have turned off and bypass design/setting is insufficient 6. Pipe blockage/airlock Christian. |
#3
|
|||
|
|||
Banshee noise from boiler
Andy R wrote:
I've recently moved into a house with a 7 year old Halstead 55 wall mounted boiler supplying an ordinary tank fed hot water and central heating system. After a while, when it all starts to heat up, the boiler begins to make a wailing type noise which can be heard all through the house. It stops as soon as the boiler stat kills the flame and if you set the stat lower it doesn't happen. The pump seems to be working fine and the problem's worse if it's just heating hot water rather than the rads as well. This implies it's related to either the boiler heat exchanger temperature or the temperature of the return flow. Anyone got any ideas how to fix it or where to start fiddling, I want to turn up the boiler stat to get the rads hotter but at the moment I can't without the kids thinking the house is haunted. TIA Andy R When our combi did this, mostly on DHW, we found it was the pump itself squealing when the temp got to 82C. Turning the temp down stopped the squealing, but it seems to have cured itself now since we have been able to increase the temp again without the problem returning. It sounded exactly like shot bearings, but possibly it was air since it went away by itself Lee -- To reply use lee.blaver and ntlworld.com |
#4
|
|||
|
|||
Banshee noise from boiler
sounds like when my powered flue fan went.
Steve "Andy R" wrote in message ... I've recently moved into a house with a 7 year old Halstead 55 wall mounted boiler supplying an ordinary tank fed hot water and central heating system. After a while, when it all starts to heat up, the boiler begins to make a wailing type noise which can be heard all through the house. It stops as soon as the boiler stat kills the flame and if you set the stat lower it doesn't happen. The pump seems to be working fine and the problem's worse if it's just heating hot water rather than the rads as well. This implies it's related to either the boiler heat exchanger temperature or the temperature of the return flow. Anyone got any ideas how to fix it or where to start fiddling, I want to turn up the boiler stat to get the rads hotter but at the moment I can't without the kids thinking the house is haunted. TIA Andy R |
#5
|
|||
|
|||
Banshee noise from boiler
"Andy R" wrote in message ... I've recently moved into a house with a 7 year old Halstead 55 wall mounted boiler supplying an ordinary tank fed hot water and central heating system. After a while, when it all starts to heat up, the boiler begins to make a wailing type noise which can be heard all through the house. It stops as soon as the boiler stat kills the flame and if you set the stat lower it doesn't happen. The pump seems to be working fine and the problem's worse if it's just heating hot water rather than the rads as well. This implies it's related to either the boiler heat exchanger temperature or the temperature of the return flow. Anyone got any ideas how to fix it or where to start fiddling, I want to turn up the boiler stat to get the rads hotter but at the moment I can't without the kids thinking the house is haunted. TIA Andy R Lime scale? |
#6
|
|||
|
|||
Banshee noise from boiler
You sure its a Banshee noise and not a hippopotamus? Only I know how to fix hippopotamus noises. Phil |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Replacing a boiler | UK diy | |||
gas boiler on landing: noise? | UK diy | |||
increasing boiler kettling noise | UK diy | |||
Boiler noise | UK diy | |||
CH boiler - making droning noise - Potterton Suprima 60 | UK diy |