ALARM PROBLEM
I have a problem with the 9450 fitted, we have just moved into our new property. The alarm is fine and works, however I want to change some light fittings in the house and when I trip the fuse for the lights the alarm goes off. I enter the code to stop it but can't seem to stop the whole system.
What can I do to stop the alarm when the electrics is tripped ? |
#2
Posted to uk.d-i-y
|
|||
|
|||
ALARM PROBLEM
|
#3
Posted to uk.d-i-y
|
|||
|
|||
ALARM PROBLEM
On 18/08/2015 10:26, Andy Burns wrote:
wrote: What can I do to stop the alarm when the electrics is tripped ? Replace the battery in the bell box (and maybe the one in the panel too?) It will be the one in the panel that has gone wrong. If the alarm rings out on a power cut then the independent one in the bell box must still be OK. It is ringing because it doesn't see signals from its controller. There will be an anti tamper on the main box too so you need to know what order to take it apart and the right engineers code. (at least that is how it works on mine) Having just had a power-cut here, the usual cacophony of alarms with dead batteries has just stopped! -- Regards, Martin Brown |
#4
Posted to uk.d-i-y
|
|||
|
|||
ALARM PROBLEM
In article ,
wrote: I have a problem with the 9450 fitted, we have just moved into our new property. The alarm is fine and works, however I want to change some light fittings in the house and when I trip the fuse for the lights the alarm goes off. I enter the code to stop it but can't seem to stop the whole system. What can I do to stop the alarm when the electrics is tripped ? fit a new battery -- Please note new email address: |
#5
Posted to uk.d-i-y
|
|||
|
|||
ALARM PROBLEM
On 18/08/2015 10:21, wrote:
I have a problem with the 9450 fitted, we have just moved into our new property. The alarm is fine and works, however I want to change some light fittings in the house and when I trip the fuse for the lights the alarm goes off. I enter the code to stop it but can't seem to stop the whole system. What can I do to stop the alarm when the electrics is tripped ? Replace the standby battery which should power the system whem the power fails. Possibly like this? https://www.tlc-direct.co.uk/Products/TSB1.html and a lot cheaper than alarm company will charge. Peter |