Just because I thought I'd have a clear weekend for doing something
useful, one of my boilers went phut. I've localised it to the PCB and will source one. Apparently this is very common on this model (Ideal Icos HE24) as the power supply has a tendency to go. Although the odds are clearly in favour of the power supply, in my researches on t'interweb, I see some general chatter to the effect that other components can cause a PCB failure. Of course this would mean a new unit would blow right away. So, while awaiting a replacement part, should I be checking all the other components and, more importantly, how? (ie am I looking for simple shorts or something more subtle?) Cheers |
#2
Posted to uk.d-i-y
|
|||
|
|||
Boiler troubles
On Mon, 23 Mar 2015 08:57:56 +0000, GMM wrote:
Although the odds are clearly in favour of the power supply, in my researches on t'interweb, I see some general chatter to the effect that other components can cause a PCB failure. Of course this would mean a new unit would blow right away. So, while awaiting a replacement part, should I be checking all the other components and, more importantly, how? (ie am I looking for simple shorts or something more subtle?) Have a word with Geoff at CET http://www.cetltd.com/ A walking compendium of every known boiler fault since the Ark and supplier of replacement fans and PCB's at sensible prices. |
#3
Posted to uk.d-i-y
|
|||
|
|||
Boiler troubles
In article ,
GMM writes: Just because I thought I'd have a clear weekend for doing something useful, one of my boilers went phut. I've localised it to the PCB and will source one. Apparently this is very common on this model (Ideal Icos HE24) as the power supply has a tendency to go. Although the odds are clearly in favour of the power supply, in my researches on t'interweb, I see some general chatter to the effect that other components can cause a PCB failure. Of course this would mean a new unit would blow right away. So, while awaiting a replacement part, should I be checking all the other components and, more importantly, how? (ie am I looking for simple shorts or something more subtle?) I would suggest getting an exchange board from Geoff @ CET Ltd - he used to be a frequent poster on here, and he may well be able to tell you what else to check before fitting the new board. http://www.cetltd.com -- Andrew Gabriel [email address is not usable -- followup in the newsgroup] |
#4
Posted to uk.d-i-y
|
|||
|
|||
Boiler troubles
On 23/03/2015 09:53, Peter Parry wrote:
On Mon, 23 Mar 2015 08:57:56 +0000, GMM wrote: Although the odds are clearly in favour of the power supply, in my researches on t'interweb, I see some general chatter to the effect that other components can cause a PCB failure. Of course this would mean a new unit would blow right away. So, while awaiting a replacement part, should I be checking all the other components and, more importantly, how? (ie am I looking for simple shorts or something more subtle?) Have a word with Geoff at CET http://www.cetltd.com/ A walking compendium of every known boiler fault since the Ark and supplier of replacement fans and PCB's at sensible prices. Thanks Peter - that was absolutely the right answer. Although his prices are a little higher than some options, he clearly knows his stuff. In case anyone finds this thread and is wondering: The only check is to make sure the fan is spinning freely as that can be the root cause of a blown pcb. |
#5
Posted to uk.d-i-y
|
|||
|
|||
Boiler troubles
In article , Peter Parry
scribeth thus On Mon, 23 Mar 2015 08:57:56 +0000, GMM wrote: Although the odds are clearly in favour of the power supply, in my researches on t'interweb, I see some general chatter to the effect that other components can cause a PCB failure. Of course this would mean a new unit would blow right away. So, while awaiting a replacement part, should I be checking all the other components and, more importantly, how? (ie am I looking for simple shorts or something more subtle?) Have a word with Geoff at CET http://www.cetltd.com/ A walking compendium of every known boiler fault since the Ark and supplier of replacement fans and PCB's at sensible prices. Seconded... -- Tony Sayer |
#6
Posted to uk.d-i-y
|
|||
|
|||
Boiler troubles
On 23/03/2015 10:06, Andrew Gabriel wrote:
In article , GMM writes: Just because I thought I'd have a clear weekend for doing something useful, one of my boilers went phut. I've localised it to the PCB and will source one. Apparently this is very common on this model (Ideal Icos HE24) as the power supply has a tendency to go. Although the odds are clearly in favour of the power supply, in my researches on t'interweb, I see some general chatter to the effect that other components can cause a PCB failure. Of course this would mean a new unit would blow right away. So, while awaiting a replacement part, should I be checking all the other components and, more importantly, how? (ie am I looking for simple shorts or something more subtle?) I would suggest getting an exchange board from Geoff @ CET Ltd - he used to be a frequent poster on here, and he may well be able to tell you what else to check before fitting the new board. http://www.cetltd.com Just to round this off, in case anyone looks in the future. CET delivered promptly, but I couldn't get the board to work. Geoff readily sent me another. This still didn't work, but the problem turned out to be the jumper settings, as there are differences betwen different iterations of the 'same' PCB and I was transferring the settings from the original. Great service from Geoff and I will definitely use them again, when I have to. Judging by what people say about this model of boiler, that won't be very long..... |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
gas usage rates of condensing boiler -prepayment meter troubles | UK diy | |||
GE dishwasher troubles | Home Ownership | |||
Looking for an M38x1.5 nut and having troubles | Metalworking | |||
Dishwasher Troubles | Home Repair | |||
Toilet troubles.... | Home Repair |