Problem with Bosch Worcester Greenstar 24 Ri Boiler
My Bosch Worcester Greenstar 24 Ri Boiler was installed in about 2008 and
has been fine until a few weeks ago. We leave the heating on constant and use the thermostat to control it. When we turn the thermostat down last thing at night, the pump keeps running for a very long time, even when there is no heat left in the radiators. There is also a lot of clicking coming from the boiler. I have resorted to turning off the mains to get it to stop. This problem is just with the heating and not the hot water, which only comes on for a brief period in the day, and the pump always shuts down normally after the hot water has been on. Has anyone else had this problem and what did you find helpful? -- |
#2
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
On Mon, 03 Mar 2014 21:44:01 +0000, Mike
wrote: My Bosch Worcester Greenstar 24 Ri Boiler was installed in about 2008 and has been fine until a few weeks ago. We leave the heating on constant and use the thermostat to control it. When we turn the thermostat down last thing at night, the pump keeps running for a very long time, even when there is no heat left in the radiators. There is also a lot of clicking coming from the boiler. I have resorted to turning off the mains to get it to stop. This problem is just with the heating and not the hot water, which only comes on for a brief period in the day, and the pump always shuts down normally after the hot water has been on. Has anyone else had this problem and what did you find helpful? I haven't had this problem but W-B have a good repair service. I would recommend calling them out. And I don't recommend switching off at the mains. The fans on some W-B boilers are prone to failure and need running regularly. -- (\__/) M. (='.'=) If a man stands in a forest and no woman is around (")_(") is he still wrong? |
#3
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
Mike wrote:
My Bosch Worcester Greenstar 24 Ri Boiler was installed in about 2008 and has been fine until a few weeks ago. We leave the heating on constant and use the thermostat to control it. When we turn the thermostat down last thing at night, the pump keeps running for a very long time, even when there is no heat left in the radiators. There is also a lot of clicking coming from the boiler. I have resorted to turning off the mains to get it to stop. This problem is just with the heating and not the hot water, which only comes on for a brief period in the day, and the pump always shuts down normally after the hot water has been on. Has anyone else had this problem and what did you find helpful? Is the clicking noise you hear that associated with cooling down or more like a relay on the control board opening and closing? |
#4
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
On Mon, 03 Mar 2014 21:44:01 +0000, Mike wrote:
Has anyone else had this problem and what did you find helpful? Similar sort of problem with the same boiler, yes. Turned out to be the cheap and nasty Chinese relays they use. Try exposing the control pcb and gently tapping it whilst listening for the characteristic relay 'click' followed by the pump cutting out. Then you'll know for sure it's a relay. However, sometimes there's no 'click' but the same thing happens anyway. In both cases, it's a relay. Even when the relays are energised and the contacts appear closed, they can still be open circuit as they often don't close with sufficient pressure to pass current. If Worcester-Bosch had used decent relays, it wouldn't have added hardly anything to the final price, so it's a shame. A service bod won't bother trying to trace a faulty relay, however, he'll just swap out the whole board (90 quid odd) and charge you for that plus the labour etc. If you're handy with a soldering iron, you can save a worthwhile sum just replacing the duff relay(s). |
#5
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
replying to Cursitor Doom , Mike wrote:
cd wrote: Similar sort of problem with the same boiler, yes. Turned out to be the cheap and nasty Chinese relays they use. Try exposing the control pcb and gently tapping it whilst listening for the characteristic relay 'click' followed by the pump cutting out. Then you'll know for sure it's a relay. However, sometimes there's no 'click' but the same thing happens anyway. In both cases, it's a relay. Even when the relays are energised and the contacts appear closed, they can still be open circuit as they often don't close with sufficient pressure to pass current. If Worcester-Bosch had used decent relays, it wouldn't have added hardly anything to the final price, so it's a shame. A service bod won't bother trying to trace a faulty relay, however, he'll just swap out the whole board (90 quid odd) and charge you for that plus the labour etc. If you're handy with a soldering iron, you can save a worthwhile sum just replacing the duff relay(s). Many thanks for this advice. I am not up to much with a soldering iron and think I will probably discuss it with the CH engineer who installed it to start with. -- |
#6
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
replying to Bob Minchin , Mike wrote:
bob.minchinREMOVE wrote: Is the clicking noise you hear that associated with cooling down or more like a relay on the control board opening and closing? No it is definitely not a cooling noise and it sounds louder and more like a technical problem inside the boiler. Not sure what could be causing it. -- |
#7
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
replying to Mark , Mike wrote:
i wrote: On Mon, 03 Mar 2014 21:44:01 +0000, Mike I haven't had this problem but W-B have a good repair service. I would recommend calling them out. And I don't recommend switching off at the mains. The fans on some W-B boilers are prone to failure and need running regularly. -- (__/) M. (='.'=) If a man stands in a forest and no woman is around (")_(") is he still wrong? Thanks Mark, I will probably end up taking that advice. -- |
#8
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
Proper hate boiler problems as you never know how much it'll cost to be put right! Mind you don't trust BG though as I read that they like to turn a modest fault into a new boiler sale for their commission!
Instead, try asking a local heating engineer for help/advice. It may be something that they can fix quite easily and quickly - if you're stuck with who to ask, try STL Heating because they were very helpful to me and they didn't mess me about either. |
#9
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
On Fri, 13 Feb 2015 04:43:13 -0800 (PST),
wrote: lying newsgroup spam for STL |
#10
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
Mike wrote:
My Bosch Worcester Greenstar 24 Ri Boiler was installed in about 2008 and has been fine until a few weeks ago. We leave the heating on constant and use the thermostat to control it. When we turn the thermostat down last thing at night, the pump keeps running for a very long time, even when there is no heat left in the radiators. There is also a lot of clicking coming from the boiler. I have resorted to turning off the mains to get it to stop. This problem is just with the heating and not the hot water, which only comes on for a brief period in the day, and the pump always shuts down normally after the hot water has been on. Has anyone else had this problem and what did you find helpful? Have you got TRVs on all rads? and if so is there a bypass valve and is it working OK. Basically the pump is running on unable to lose the excess heat possibly because the bypass valve is not opening? |
#11
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
Bob Minchin wrote:
Mike wrote: My Bosch Worcester Greenstar 24 Ri Boiler was installed in about 2008 and has been fine until a few weeks ago. We leave the heating on constant and use the thermostat to control it. When we turn the thermostat down last thing at night, the pump keeps running for a very long time, even when there is no heat left in the radiators. There is also a lot of clicking coming from the boiler. I have resorted to turning off the mains to get it to stop. This problem is just with the heating and not the hot water, which only comes on for a brief period in the day, and the pump always shuts down normally after the hot water has been on. Has anyone else had this problem and what did you find helpful? Have you got TRVs on all rads? and if so is there a bypass valve and is it working OK. Basically the pump is running on unable to lose the excess heat possibly because the bypass valve is not opening? Bugger - did not spot this was a vintage thread and even one I'd replied to before! DOH |
#12
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
On Monday, March 3, 2014 at 9:44:01 PM UTC, Mike wrote:
My Bosch Worcester Greenstar 24 Ri Boiler was installed in about 2008. There is also a lot of clicking coming from the boiler. The whole electrical wiring circuit associated with the boiler and the boiler itself needs to be checked. Sometimes soon after the clicking noise starts the boiler stops working.For your safety and the safety of others around you if you are not qualified never remove the boiler cover and tap on the relays as stated in previous posting. Taping on the printed circuit board relay might cause damage to the board electronic components or circuits. Thousands of Worcester Bosch boilers repaired and serviced. Electronic engineer and Electrical Engineer Gas Safe registered engineer before working for Worcester Bosch, whilst working for Worcester Bosch as a boiler breakdown engineer and currently a gas Safe registered engineer. Mohun 07737845657 www.worcesterboilerrepairs.com |
#14
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
replying to John Rumm, Tony wrote:
have this problem, last night with water/heating off boiler was still starting/clicking. luckily engineer visited this am and was able to hear noise. He spoke with Worcestor boilers support and they say its likely to be voltage leakage triggering the boiler/fan and have suggested fitting a capacitor to solve problem...and if that doesnt work then new board. Will post update when i know its fixed -- posted from http://www.homeownershub.com/uk-diy/...er-959948-.htm |
#15
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
On 26/05/2016 14:44, Tony wrote:
replying to John Rumm, Tony wrote: have this problem, last night with water/heating off boiler was still starting/clicking. luckily engineer visited this am and was able to hear noise. He spoke with Worcestor boilers support and they say its likely to be voltage leakage triggering the boiler/fan and have suggested fitting a capacitor to solve problem...and if that doesnt work then new board. Will post update when i know its fixed If it does turn out to be a PCB, then talk to Geoff at http://www.cetltd.com/ Chances are he will have a remanufactured board to swap at a fraction of the WB price. -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |
#16
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
On Thu, 26 May 2016 17:55:25 +0100, John Rumm wrote:
On 26/05/2016 14:44, Tony wrote: replying to John Rumm, Tony wrote: have this problem, last night with water/heating off boiler was still starting/clicking. luckily engineer visited this am and was able to hear noise. He spoke with Worcestor boilers support and they say its likely to be voltage leakage triggering the boiler/fan and have suggested fitting a capacitor to solve problem...and if that doesnt work then new board. Will post update when i know its fixed If it does turn out to be a PCB, then talk to Geoff at http://www.cetltd.com/ Chances are he will have a remanufactured board to swap at a fraction of the WB price. With ours (same model) it turned out to be a burned/melted wiring harness subsequent to a seal failure. I got a fixed price repair and they rebuilt most of the boiler. -- My posts are my copyright and if @diy_forums or Home Owners' Hub wish to copy them they can pay me £1 a message. Use the BIG mirror service in the UK: http://www.mirrorservice.org *lightning surge protection* - a w_tom conductor |
#17
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
"Bob Eager" wrote in message ... On Thu, 26 May 2016 17:55:25 +0100, John Rumm wrote: On 26/05/2016 14:44, Tony wrote: replying to John Rumm, Tony wrote: have this problem, last night with water/heating off boiler was still starting/clicking. luckily engineer visited this am and was able to hear noise. He spoke with Worcestor boilers support and they say its likely to be voltage leakage triggering the boiler/fan and have suggested fitting a capacitor to solve problem...and if that doesnt work then new board. Will post update when i know its fixed If it does turn out to be a PCB, then talk to Geoff at http://www.cetltd.com/ Chances are he will have a remanufactured board to swap at a fraction of the WB price. With ours (same model) it turned out to be a burned/melted wiring harness subsequent to a seal failure. I got a fixed price repair and they rebuilt most of the boiler. OOI what price, Bob? |
#18
Posted to uk.d-i-y
|
|||
|
|||
Problem with Bosch Worcester Greenstar 24 Ri Boiler
On 29/11/2017 18:44, Grannysmith wrote:
replying to Mike, Grannysmith wrote: I too have a Worcester Greenstar Ri it is 8yrs old , it is making the same clicking noise my man was going to have a word with the Worcester dealer but as yet no comeback. It is making the noise all the time now but only when the heating is on not the water Read the bloody date of the original post !! (Three years ago), and please use a proper newsgroup reader, not that pathetic forum. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Worcester-Bosch CDi 30 Greenstar | UK diy | |||
Worcester Bosch Greenstar won't fire up | UK diy | |||
[?] Worcester-Bosch Greenstar boiler - pressure adjustment. | UK diy | |||
Worcester Bosch Greenstar boiler | UK diy | |||
Worcester (Bosch) Greenstar HE Combi Boiler question | UK diy |