I've got a 100mm inline extractor fan in the ensuite; there's a vent in the
ceiling and it ducts the air up into the roofspace (in corrugated flexible ducting) and as this is a dormer-style house with a very low roofline, it passes down under the tiles in 100mm rigid flat ducting to a grille just below the guttering. It's really very ineffective though, and while I'm scrabbling around in the roof space sorting out my downlighter wiring I thought I might try fixing this too... I was considering replacing the 100mm fan with a 150mm model; however, realistically there's no easy way to upgrade the length of fixed 100mm ducting (about 1-1.5m worth) which runs under the roof tiles. I would replace the flexible stuff in the roof space with 150mm ducting, probably rigid rather than the flexible hose. Question is, would that be worthwhile at all? Would the old 100mm section, which I can't upgrade, just act as a bottleneck to eliminate any benefit? Thanks -- David |
#2
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
In message , Lobster
writes I've got a 100mm inline extractor fan in the ensuite; there's a vent in the ceiling and it ducts the air up into the roofspace (in corrugated flexible ducting) and as this is a dormer-style house with a very low roofline, it passes down under the tiles in 100mm rigid flat ducting to a grille just below the guttering. It's really very ineffective though, and while I'm scrabbling around in the roof space sorting out my downlighter wiring I thought I might try fixing this too... I was considering replacing the 100mm fan with a 150mm model; however, realistically there's no easy way to upgrade the length of fixed 100mm ducting (about 1-1.5m worth) which runs under the roof tiles. I would replace the flexible stuff in the roof space with 150mm ducting, probably rigid rather than the flexible hose. Question is, would that be worthwhile at all? Would the old 100mm section, which I can't upgrade, just act as a bottleneck to eliminate any benefit? Thanks Monrose do a high powered 100mm fan. -- bert |
#3
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 15/02/2014 19:13, Lobster wrote:
I've got a 100mm inline extractor fan in the ensuite; there's a vent in the ceiling and it ducts the air up into the roofspace (in corrugated flexible ducting) and as this is a dormer-style house with a very low roofline, it passes down under the tiles in 100mm rigid flat ducting to a grille just below the guttering. It's really very ineffective though, and while I'm scrabbling around in the roof space sorting out my downlighter wiring I thought I might try fixing this too... I was considering replacing the 100mm fan with a 150mm model; however, realistically there's no easy way to upgrade the length of fixed 100mm ducting (about 1-1.5m worth) which runs under the roof tiles. I would replace the flexible stuff in the roof space with 150mm ducting, probably rigid rather than the flexible hose. Question is, would that be worthwhile at all? Would the old 100mm section, which I can't upgrade, just act as a bottleneck to eliminate any benefit? Thanks Have you considered a mixed flow fan? They can deliver a good flow rate under high resistance. I have a 100mm Vent Axia one which has about a metre of flexible ductwork on each side and it vents out through a dedicated roof vent tile. It works extremely well, the roof tile creates a lot of resistance due to its design but the fan is still able to deliver a decent flow rate. http://www.vent-axia.com/product/acm...ns-acm100.html -- Dawood |
#4
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On Sat, 15 Feb 2014 19:13:39 GMT, Lobster wrote:
I've got a 100mm inline extractor fan in the ensuite; there's a vent in the ceiling and it ducts the air up into the roofspace (in corrugated flexible ducting) and as this is a dormer-style house with a very low roofline, it passes down under the tiles in 100mm rigid flat ducting to a grille just below the guttering. It's really very ineffective though, and while I'm scrabbling around in the roof space sorting out my downlighter wiring I thought I might try fixing this too... I was considering replacing the 100mm fan with a 150mm model; however, realistically there's no easy way to upgrade the length of fixed 100mm ducting (about 1-1.5m worth) which runs under the roof tiles. I would replace the flexible stuff in the roof space with 150mm ducting, probably rigid rather than the flexible hose. Question is, would that be worthwhile at all? Would the old 100mm section, which I can't upgrade, just act as a bottleneck to eliminate any benefit? Thanks Rigid would, in itself, help, as corrugations cause a lot of drag. -- Peter. The gods will stay away whilst religions hold sway |
#5
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
PeterC wrote in
: On Sat, 15 Feb 2014 19:13:39 GMT, Lobster wrote: I've got a 100mm inline extractor fan in the ensuite; there's a vent in the ceiling and it ducts the air up into the roofspace (in corrugated flexible ducting) and as this is a dormer-style house with a very low roofline, it passes down under the tiles in 100mm rigid flat ducting to a grille just below the guttering. It's really very ineffective though, and while I'm scrabbling around in the roof space sorting out my downlighter wiring I thought I might try fixing this too... I was considering replacing the 100mm fan with a 150mm model; however, realistically there's no easy way to upgrade the length of fixed 100mm ducting (about 1-1.5m worth) which runs under the roof tiles. I would replace the flexible stuff in the roof space with 150mm ducting, probably rigid rather than the flexible hose. Question is, would that be worthwhile at all? Would the old 100mm section, which I can't upgrade, just act as a bottleneck to eliminate any benefit? Thanks Rigid would, in itself, help, as corrugations cause a lot of drag. Corrugations also allow a build up of fluff. What is meant by "mixed flow"? -- DerbyBorn --- This email is free from viruses and malware because avast! Antivirus protection is active. http://www.avast.com |
#6
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 15/02/2014 23:12, DerbyBorn wrote:
PeterC wrote in : On Sat, 15 Feb 2014 19:13:39 GMT, Lobster wrote: I've got a 100mm inline extractor fan in the ensuite; there's a vent in the ceiling and it ducts the air up into the roofspace (in corrugated flexible ducting) and as this is a dormer-style house with a very low roofline, it passes down under the tiles in 100mm rigid flat ducting to a grille just below the guttering. It's really very ineffective though, and while I'm scrabbling around in the roof space sorting out my downlighter wiring I thought I might try fixing this too... I was considering replacing the 100mm fan with a 150mm model; however, realistically there's no easy way to upgrade the length of fixed 100mm ducting (about 1-1.5m worth) which runs under the roof tiles. I would replace the flexible stuff in the roof space with 150mm ducting, probably rigid rather than the flexible hose. Question is, would that be worthwhile at all? Would the old 100mm section, which I can't upgrade, just act as a bottleneck to eliminate any benefit? Thanks Rigid would, in itself, help, as corrugations cause a lot of drag. Corrugations also allow a build up of fluff. What is meant by "mixed flow"? "In a mixed flow fan the air flows in both axial and radial direction relative to the shaft. Mixed flow fans develops higher pressures than axial fans." Read mo http://www.engineeringtoolbox.com/fan-types-d_142.html -- Dawood |
#7
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Lobster wrote:
I've got a 100mm inline extractor fan in the ensuite; there's a vent in the ceiling and it ducts the air up into the roofspace (in corrugated flexible ducting) and as this is a dormer-style house with a very low roofline, it passes down under the tiles in 100mm rigid flat ducting to a grille just below the guttering. It's really very ineffective though, and while I'm scrabbling around in the roof space sorting out my downlighter wiring I thought I might try fixing this too... I was considering replacing the 100mm fan with a 150mm model; however, realistically there's no easy way to upgrade the length of fixed 100mm ducting (about 1-1.5m worth) which runs under the roof tiles. I would replace the flexible stuff in the roof space with 150mm ducting, probably rigid rather than the flexible hose. Question is, would that be worthwhile at all? Would the old 100mm section, which I can't upgrade, just act as a bottleneck to eliminate any benefit? Thanks Is the fan the right way round? Yes, I know it's a stupid question! |
#8
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() "Lobster" wrote in message . 236... I've got a 100mm inline extractor fan in the ensuite; there's a vent in the ceiling and it ducts the air up into the roofspace (in corrugated flexible ducting) and as this is a dormer-style house with a very low roofline, it passes down under the tiles in 100mm rigid flat ducting to a grille just below the guttering. It's really very ineffective though, and while I'm scrabbling around in the roof space sorting out my downlighter wiring I thought I might try fixing this too... I was considering replacing the 100mm fan with a 150mm model; however, realistically there's no easy way to upgrade the length of fixed 100mm ducting (about 1-1.5m worth) which runs under the roof tiles. I would replace the flexible stuff in the roof space with 150mm ducting, probably rigid rather than the flexible hose. Question is, would that be worthwhile at all? Would the old 100mm section, which I can't upgrade, just act as a bottleneck to eliminate any benefit? There are two aspects to fans, the volume they shift and the pressure they develop. (As with all bladed pumps, centrifugal and axial) It sounds like your fan does not develop enough pressure. There are special high pressure fans for long ducts, usually centrifugal. |
#9
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Assuming you can join them in a sloping kind of way, it will work, is all i
can say, as I've seen this sort ogf thing done via a reducer. I guess it depends on how much 'oomph' the fan can deliver! Brian -- From the Sofa of Brian Gaff Reply address is active "Lobster" wrote in message . 236... I've got a 100mm inline extractor fan in the ensuite; there's a vent in the ceiling and it ducts the air up into the roofspace (in corrugated flexible ducting) and as this is a dormer-style house with a very low roofline, it passes down under the tiles in 100mm rigid flat ducting to a grille just below the guttering. It's really very ineffective though, and while I'm scrabbling around in the roof space sorting out my downlighter wiring I thought I might try fixing this too... I was considering replacing the 100mm fan with a 150mm model; however, realistically there's no easy way to upgrade the length of fixed 100mm ducting (about 1-1.5m worth) which runs under the roof tiles. I would replace the flexible stuff in the roof space with 150mm ducting, probably rigid rather than the flexible hose. Question is, would that be worthwhile at all? Would the old 100mm section, which I can't upgrade, just act as a bottleneck to eliminate any benefit? Thanks -- David |
#10
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Lobster wrote:
I've got a 100mm inline extractor fan in the ensuite; there's a vent in the ceiling and it ducts the air up into the roofspace (in corrugated flexible ducting) and as this is a dormer-style house with a very low roofline, it passes down under the tiles in 100mm rigid flat ducting to a grille just below the guttering. It's really very ineffective though, and while I'm scrabbling around in the roof space sorting out my downlighter wiring I thought I might try fixing this too... I was considering replacing the 100mm fan with a 150mm model; however, realistically there's no easy way to upgrade the length of fixed 100mm ducting (about 1-1.5m worth) which runs under the roof tiles. I would replace the flexible stuff in the roof space with 150mm ducting, probably rigid rather than the flexible hose. Question is, would that be worthwhile at all? Would the old 100mm section, which I can't upgrade, just act as a bottleneck to eliminate any benefit? After recommendation here, I bought one of these: http://www.tlc-direct.co.uk/Products...ENTslashT.html Admittedly not cheap, but I was amazed by how quiet it was, I had to feel the air to be sure it was running. The airflow is far better than the (failed) cheap one it replaced. It can push-fit into the pipework, and is readily removable for cleaning. Chris -- Chris J Dixon Nottingham UK Plant amazing Acers. |
#11
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 16 Feb 2014, "harryagain" grunted:
"Lobster" wrote in message . 236... I've got a 100mm inline extractor fan in the ensuite; there's a vent in the ceiling and it ducts the air up into the roofspace (in corrugated flexible ducting) and as this is a dormer-style house with a very low roofline, it passes down under the tiles in 100mm rigid flat ducting to a grille just below the guttering. It's really very ineffective though, and while I'm scrabbling around in the roof space sorting out my downlighter wiring I thought I might try fixing this too... I was considering replacing the 100mm fan with a 150mm model; however, realistically there's no easy way to upgrade the length of fixed 100mm ducting (about 1-1.5m worth) which runs under the roof tiles. I would replace the flexible stuff in the roof space with 150mm ducting, probably rigid rather than the flexible hose. Question is, would that be worthwhile at all? Would the old 100mm section, which I can't upgrade, just act as a bottleneck to eliminate any benefit? There are two aspects to fans, the volume they shift and the pressure they develop. (As with all bladed pumps, centrifugal and axial) It sounds like your fan does not develop enough pressure. There are special high pressure fans for long ducts, usually centrifugal. Yeah, I think the answer is maybe just to replace it with a 100mm centrifugal model. The plot thickens actually: the 150mm fan I was originally thinking of going for was http://tinyurl.com/ma4xp3c (or http://www.toolstation.com/shop/Elec...mm%20Part%20L% 20Inline %20Shower%20Fan%20Kit%20with%20Timer/d190/sd280/p97314); however I hadn't originally spotted that this doesn't coincide with the standard ducting sizes which are 100mm or 125mm. Weird! -- David |
#12
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On Sunday, February 16, 2014 11:34:07 AM UTC, Chris J Dixon wrote:
Lobster wrote: I've got a 100mm inline extractor fan in the ensuite; there's a vent in the ceiling and it ducts the air up into the roofspace (in corrugated flexible ducting) and as this is a dormer-style house with a very low roofline, it passes down under the tiles in 100mm rigid flat ducting to a grille just below the guttering. It's really very ineffective though, and while I'm scrabbling around in the roof space sorting out my downlighter wiring I thought I might try fixing this too... I was considering replacing the 100mm fan with a 150mm model; however, realistically there's no easy way to upgrade the length of fixed 100mm ducting (about 1-1.5m worth) which runs under the roof tiles. I would replace the flexible stuff in the roof space with 150mm ducting, probably rigid rather than the flexible hose. Question is, would that be worthwhile at all? Would the old 100mm section, which I can't upgrade, just act as a bottleneck to eliminate any benefit? After recommendation here, I bought one of these: http://www.tlc-direct.co.uk/Products...ENTslashT.html Admittedly not cheap, but I was amazed by how quiet it was, I had to feel the air to be sure it was running. The airflow is far better than the (failed) cheap one it replaced. It can push-fit into the pipework, and is readily removable for cleaning. +1 Excellent fans, very quiet. That is until you control them with a triac controller, but that is a matter for the other post ! Simon. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
extractor reducer 150mm to 80mm | UK diy | |||
150mm extract ducting - source? | UK diy | |||
Gutter guards: worth installing? | UK diy | |||
Extractor fan ducting 125mm to 100mm | UK diy | |||
100mm extractor hood ducting problem | UK diy |