I have some Drayton TRV3 units which are probably 15 years old. I find
that on the frost setting they do shut off the water supply and the
radiator goes cold but only at room temperatures of 15C or so, at lower
room temperatures the radiator is full on even on the frost setting. I
assumed that the wax capsule (or whatever is in them) had broken and
ordered some replacement heads. (which being TRV3 to TRV4 converters are
not as cheap as simple TRV4 heads). Anyway having fitted the
replacements curiosity got the better of me and I took one of the old
ones apart.

https://picasaweb.google.com/lh/phot...t=d irectlink


I found that when taken from the cold outdoors to the warm indoors the
extension of the actuator pin in the TRV head (ie the bit that presses
on the little pip in the water valve) varied between 20mm and 25 mm,

(Dimension A on here)
https://picasaweb.google.com/lh/phot...t=d irectlink

which indicates that the wax capsule is indeed doing its stuff.
Furthermore the very end of the actuator arm was a screwed in brass
hexagon, and if I was a betting man I would say that when manufactured
there is/was a calibration table to show the total length of the
actuator arm for the ambient condition in the factory.

My thought process is if I extend the length of the actuator by a turn
or so this should shut off the water supply at a lower temperature
driving the room down to say 10C (or lower) on the frost setting.

My concern is when the actuator extends to maximum length and the water
valve is closed where is the extra movement of the actuator absorbed?
If I press with my thumb on the actuator shaft (the same way that the
pin in the valve will do) there appears to be no give or resilience.

On a completely un-tampered with unit this would be the equivalent of
what happens to the unit when the head selected temp is "frost setting"
but the body temperature reaches say 30C in high summer. The valve was
closed at 5C but now its closed and a further 25C of expansion needs to
take place - where is the spring give?

Any ideas or help would be appreciated as this might mean that I can fix
at least some of the remaining 4 heads that I have so far not bought
replacements for.


Chris.

 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Drilling into old VERY hard concrete - or give up and use "no nails"? Jonathan UK diy 34 April 12th 17 07:31 PM
OT - Will Sarah "The Quitter" Palin Give Back Her PAC Money To The Donors? Steve B[_10_] Metalworking 0 October 7th 11 01:50 AM
I am looking for a local source for "Rockwool" / "Mineral Wool" /"Safe & Sound" / "AFB" jtpr Home Repair 3 June 10th 10 06:27 AM
For women who desire the traditional 12-marker dials, the "Faceto,""Juro" and "Rilati" all add a little more functionality, without sacrificingthe diamonds. [email protected] Woodworking 0 April 19th 08 11:12 AM
OK, I give up: what is a "registered" chisel? David Woodworking 32 January 28th 06 03:12 PM


All times are GMT +1. The time now is 01:06 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"