Hi all,

I'm building a computer server farm, network switch rack and
TV/Sat/Radio headend in my loft. All of these gadgets need 240 volt
power via 13amp plugs.

This means lots and lots of double sockets. :-)

I'm planning on putting in a 32A RCBO in the CU to power all this kit in
the loft via suitable wiring.

The reason for a separate RCBO is to ensure high power availability so
that faults elsewhere in the house do not kill power and hence cause
data corruption in the computer servers.

Now, I have acquired some 2nd hand bench power strips that are basically
white plastic trunking with double sockets inserted. They are wired in a
ring main fashion within the trunking and had a RCBO in at one end.

See https://www.dropbox.com/s/562yp1r27v...Close%20up.JPG and

https://www.dropbox.com/s/kfcvrg71q9...mal%20view.JPG

I intend to modify all these by putting in as many double sockets as the
trunking allows which will be 10 double sockets over a length of 2 metres.

This entire assembly will then be fixed to the loft gable end wall and
then provide a fixed wired cable from this assembly back to the CU.

This will then power all my kit.

Now my questions:

Should I use a single run of 4mm2 cable run back to the 32A RCBO or
should I use 2.5mm2 T&E in a ring main fashion as per normal practice
for ring main sockets?

Will all this be compliant with wiring regs such as socket spacing &
density?

Regards,

Stephen.





 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Server room rack power [email protected] UK diy 20 January 13th 09 02:15 PM
Power For Server Room AJ UK diy 11 March 17th 07 06:16 PM
Server Room Power Supply Richard UK diy 2 March 16th 07 03:06 PM
Computer room static blowing server power supplies T Electronics Repair 25 April 8th 06 03:13 AM
Cooling Server Room Richard Conway UK diy 13 July 3rd 05 10:15 PM


All times are GMT +1. The time now is 08:11 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"