I'm planning to build something like this...
http://www.soundproofingcompany.com/..._construction/

....with 4x2 top+bottom, and 3x2 studs.

Has anyone every successfully put a corner into one of these without
joining the two sides together (which would make the whole thing
pointless)? If so, how?!

Also, Noggins.I've seen suggestions to put little 45 degree pieces top
and bottom internally, since conventional noggins would simply couple
the two walls together (making it pointless). Any other ideas?

You can build them further apart, like this:
http://www.diydata.com/general_build...tion_proof.php
....leaving room for conventional noggins without bridging the two
sides, but I don't want to "waste" that much space.

Shall I try to fit sound insulation into the little 1" gap behind each
stud, or just put it in the larger gaps between studs?

Cheers,
David.
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,565
Default staggered stud partition wall - noggins, corners, and soundinsulation

On Jun 3, 12:44*am, David Robinson
wrote:
I'm planning to build something like this...http://www.soundproofingcompany.com/...aggered_stud_w...

...with 4x2 top+bottom, and 3x2 studs.

Has anyone every successfully put a corner into one of these without
joining the two sides together (which would make the whole thing
pointless)? If so, how?!


Corners are relatievly rigid, so dont much compromise sound
resistance.


Also, Noggins.I've seen suggestions to put little 45 degree pieces top
and bottom internally, since conventional noggins would simply couple
the two walls together (making it pointless). Any other ideas?


you could upsize from 2x3 to 2x4 uprights at the cost of another inch
of space, but I dont know how much sound insulation youre looking for.

2 layers of 12mm PB on each side helps too. If not enough space for
that you can always stick scrap PB or even plaster to the inner side
of one of the PB where the gaps between studs are to stiffen and
weight it.

You can also add weights to the uprights to redce movement. Its less
easy with no noggings, but still doable.


You can build them further apart, like this:http://www.diydata.com/general_build.../partition_pro...
...leaving room for conventional noggins without bridging the two
sides, but I don't want to "waste" that much space.

Shall I try to fit sound insulation into the little 1" gap behind each
stud


no

, or just put it in the larger gaps between studs?
Cheers,
David.



NT
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,379
Default staggered stud partition wall - noggins, corners, and soundinsulation

On 3 June, 00:44, David Robinson
wrote:
I'm planning to build something like this...http://www.soundproofingcompany.com/...aggered_stud_w...

...with 4x2 top+bottom, and 3x2 studs.

Has anyone every successfully put a corner into one of these without
joining the two sides together (which would make the whole thing
pointless)? If so, how?!

Also, Noggins.I've seen suggestions to put little 45 degree pieces top
and bottom internally, since conventional noggins would simply couple
the two walls together (making it pointless). Any other ideas?

You can build them further apart, like this:http://www.diydata.com/general_build.../partition_pro...
...leaving room for conventional noggins without bridging the two
sides, but I don't want to "waste" that much space.

Shall I try to fit sound insulation into the little 1" gap behind each
stud, or just put it in the larger gaps between studs?

Cheers,
David.


You can set conventional noggins on their side, so using 50*100mm
studs you would need to be only a shade over 150mm wide top and sole
plates.

Everything counts, so thicker studs (particularly with higher
ceilings) give extra stiffness, as does adding extra rows of noggins.

Thicker plasterboard, sound deadening plasterboard (e.g. LaFarge dB
check) double staggered layers, denser sound insulation material,
peripheral airtight seals around the wall, more screws, carefully
positioned sockets - all counts - as does just good workmanship.

Check out Part E of the approved docs for lots of proven good advice.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Stud partition - how thin can it be? [email protected] UK diy 36 June 23rd 20 11:44 PM
Stud partition and noise nsulation [email protected] UK diy 7 October 20th 08 03:49 PM
Stud partition and noise nsulation [email protected] UK diy 0 October 20th 08 01:01 PM
Sound proofing a stud partition Trab Nospmis UK diy 7 February 25th 05 09:40 AM
Stud Partition and RSJ inNeedofHelp UK diy 5 November 4th 04 09:35 PM


All times are GMT +1. The time now is 02:55 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"