Default Solar Roof Holes?

Solar Roof Holes?

Whilst they reslate my roof
I'm having scaffold bars attached and flashed
to attach some Navitron solar panels,
But where to put holes for the water pipes?
Should they both be lower than the panels so that I can drain them?
Or one above it and one below it?

I will be studying the water system etcetera when the roofing's done,
and the scaffold is down,
but have just realised I must leave a hole for the water pipes!

advice please...

[g]
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 14,085
Default Solar Roof Holes?

On Tue, 02 Mar 2010 11:32:22 +0000, george [dicegeorge] wrote:

Whilst they reslate my roof I'm having scaffold bars attached and
flashed to attach some Navitron solar panels,


Sensible to get the roof work done at the same time.

But where to put holes for the water pipes?


Which sort of panel? Evacuated tube or flat plate?

The tube type have a manifold that runs along the top into which the
heat tubes project, so I'd expect a pipe hole each end at the top.
Flat panel I'd expect diagonal oposite corners.

The navitron site is normally preety good isn't the information
there, you'll need panel sizes anyway to get rough posistions for the
mount anyway.

--
Cheers
Dave.



  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 21
Default Solar Roof Holes?


"george [dicegeorge]" wrote in message
...
Solar Roof Holes?

Whilst they reslate my roof
I'm having scaffold bars attached and flashed
to attach some Navitron solar panels,
But where to put holes for the water pipes?
Should they both be lower than the panels so that I can drain them?
Or one above it and one below it?

I will be studying the water system etcetera when the roofing's done,
and the scaffold is down,
but have just realised I must leave a hole for the water pipes!

advice please...

[g]


I installed a Navitron tube collector a couple of weeks ago with a RESOL
"flowcon" pump station on a sealed loop of about 9 litres capacity.

In my case I have clay tiles so the holes were simple to drill. Pipes go up
a couple of inches (parallel to roof) then down. Within the loft I have
tails on both flow and return that terminate in a vent cap at the apex.
Used 15mm copper with 19mm thick Armaflex for the circuit (about 12 metres
loop length).

With the pipes going up any air is forced into 15mm pipe and easily pumped
around. No problem.

When I first commissioned I used water and literally blew most air out of
the system when filling it. It was easy. After a couple of weeks to make
sure there were no leaks I refilled with glycol and water and to be honest
bleeding this has been a hassle, but nothing insurmountable so long as your
pump has enough "jaffa".

Using the SFB30-47 panel I yielded about 7 kWh yesterday. V impressed.

david





  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,356
Default Solar Roof Holes?

On Tue, 02 Mar 2010 11:32:22 +0000 someone who may be "george
[dicegeorge]" wrote this:-

to attach some Navitron solar panels,
But where to put holes for the water pipes?
Should they both be lower than the panels so that I can drain them?
Or one above it and one below it?


Assuming tubes rather than a flat panel, at each end of the
manifold, as already stated.

If the pipes run down slightly then the panel will automatically
drain when you are fiddling with it. Provided the slope is not too
great then any air should be forced round to the air bottle you have
provided inside the house. Be careful what you use for the vent on
this, if the panel suffers stagnation this will get very hot and the
bottle and pipes could be filled with steam, or water at over 100C.
The water will be forced down the flow and return by the steam
bubble, having a gentle slope away from the panel means no more
water will flow into the panel to be turned into steam.

You can fit the manifold while the scaffolding is up. Don't fit the
tubes until the water system and its controls have been tested and
shown to work. Then put the tubes in as the last operation.



--
David Hansen, Edinburgh
I will *always* explain revoked encryption keys, unless RIP prevents me
http://www.opsi.gov.uk/acts/acts2000...#pt3-pb3-l1g54
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Solar reflective paint for polycarbonate roof. brass monkey UK diy 10 July 28th 13 09:45 AM
Mounting Solar A Frame to flat roof. Crispin UK diy 7 August 20th 08 02:03 PM
Solar Powered Roof Vent Lou Leciejewski Home Repair 7 April 21st 08 01:50 AM
Roof mounted Solar heating panels fredbloggstwo UK diy 4 December 29th 06 12:34 PM
Conservatory roof and 'Solar Control Inserts' puk UK diy 0 September 2nd 03 09:26 AM


All times are GMT +1. The time now is 06:18 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"