#1
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Does anyone happen to have a manual for one of these to hand please ?
(I don't know which specific model it is from the range atm) I'm just trying to work out what's making it run so noisily - the rads are bled, but even with them off it sounds like it's pumping a huge amount of air around the system (gurgling like a b*stard to be more precise) I've just tried to lower the temp at the boiler end in case it was kettling causing it (don't normally notice if it is, as it's in a garage) |
#2
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Colin Wilson wrote:
Does anyone happen to have a manual for one of these to hand please ? (I don't know which specific model it is from the range atm) I'm just trying to work out what's making it run so noisily - the rads are bled, but even with them off it sounds like it's pumping a huge amount of air around the system (gurgling like a b*stard to be more precise) I've just tried to lower the temp at the boiler end in case it was kettling causing it (don't normally notice if it is, as it's in a garage) Not for the Space saver, but I have one for Glow-worm Hideaway if that's any use to you? Don |
#3
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Not for the Space saver, but I have one for Glow-worm Hideaway if that's
any use to you? ....possibly - Ed or the other chap who repairs PCBs might have one to hand, but I might get back to you... Thanks for the reply :-) |
#4
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
In message ,
Colin Wilson o.uk writes Not for the Space saver, but I have one for Glow-worm Hideaway if that's any use to you? ...possibly - Ed or the other chap who repairs PCBs might have one to hand, The bloke who repairs PCBS ? You mean the one who pays other people to repair them for him ... -- bumsnase |
#5
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
...possibly - Ed or the other chap who repairs PCBs might have one to
hand, The bloke who repairs PCBS ? You mean the one who pays other people to repair them for him ... He's got enough positive feedback for me to consider him a worthwhile bet ! |
#6
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
In message ,
Colin Wilson o.uk writes ...possibly - Ed or the other chap who repairs PCBs might have one to hand, The bloke who repairs PCBS ? You mean the one who pays other people to repair them for him ... He's got enough positive feedback for me to consider him a worthwhile bet ! I still don't repair them myself much any more -- geoff |
#7
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
In message , Donwill
writes Colin Wilson wrote: Does anyone happen to have a manual for one of these to hand please ? (I don't know which specific model it is from the range atm) I'm just trying to work out what's making it run so noisily - the rads are bled, but even with them off it sounds like it's pumping a huge amount of air around the system (gurgling like a b*stard to be more precise) I've just tried to lower the temp at the boiler end in case it was kettling causing it (don't normally notice if it is, as it's in a garage) Not for the Space saver, but I have one for Glow-worm Hideaway if that's any use to you? Don Completely different animal -- geoff |
#8
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Does anyone happen to have a manual for one of these to hand please ?
(I don't know which specific model it is from the range atm) Just a small update, it's the Spacesaver Mk2 50BR model |
#9
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
In message , Colin
Wilson o.uk writes Does anyone happen to have a manual for one of these to hand please ? (I don't know which specific model it is from the range atm) I'm just trying to work out what's making it run so noisily - the rads are bled, but even with them off it sounds like it's pumping a huge amount of air around the system (gurgling like a b*stard to be more precise) I've just tried to lower the temp at the boiler end in case it was kettling causing it (don't normally notice if it is, as it's in a garage) I prolly have one, but I doubt it will be of much use for what you're describing If you have a leak somewhere that's letting air in, it could be anywhere in the system not necessarily in the boiler You might find that your auto bleed valve isn't working properly, it will be somewhere at the top of the boiler and is usually gold in colour and circular with a screw top an inch and a half in diameter and two inches tall Check out the joints in the boiler to see if there is evidence of water leaks especially around the heat exchanger The only other (continually) moving parts in the boiler are the fan, and the pump if its part of the boiler -- geoff |
#10
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
If you have a leak somewhere that's letting air in, it could be anywhere
in the system not necessarily in the boiler It's not a pressurised system either, so could be anywhere :-} You might find that your auto bleed valve isn't working properly, it will be somewhere at the top of the boiler and is usually gold in colour and circular with a screw top an inch and a half in diameter and two inches tall I'll check it out over the next few days... Check out the joints in the boiler to see if there is evidence of water leaks especially around the heat exchanger The only other (continually) moving parts in the boiler are the fan, and the pump if its part of the boiler No sign of leakage internally, and the pump is seperate :-} |
#11
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() "Colin Wilson" o.uk wrote in message ... Does anyone happen to have a manual for one of these to hand please ? (I don't know which specific model it is from the range atm) I'm just trying to work out what's making it run so noisily - the rads are bled, but even with them off it sounds like it's pumping a huge amount of air around the system (gurgling like a b*stard to be more precise) I've just tried to lower the temp at the boiler end in case it was kettling causing it (don't normally notice if it is, as it's in a garage) If your system is open vented then check the feed & expansion tank (probably in the loft). The float valve may have stuck causing the tank to run dry, a few yanks up and down usually frees it and gets the water running again. Alternatively if the tank is full then check that the cold feed is not blocked where it tees into the system. |
#12
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
If your system is open vented then check the feed & expansion tank (probably
in the loft). The float valve may have stuck causing the tank to run dry, a few yanks up and down usually frees it and gets the water running again. Alternatively if the tank is full then check that the cold feed is not blocked where it tees into the system. Thanks for that - we've already drained and refilled it a few times recently while decorating, and everything seems to work as normal though :-} |
#13
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() "Colin Wilson" o.uk wrote in message ... If your system is open vented then check the feed & expansion tank (probably in the loft). The float valve may have stuck causing the tank to run dry, a few yanks up and down usually frees it and gets the water running again. Alternatively if the tank is full then check that the cold feed is not blocked where it tees into the system. Thanks for that - we've already drained and refilled it a few times recently while decorating, and everything seems to work as normal though :-} It certainly seems like an air problem then if it has been drained & refilled several times. You should be able to vent most of the air through the pump vent screw. Loosen the screw and run the boiler. Put a container or piece of rag under the pump to catch the drips. |
#14
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
It certainly seems like an air problem then if it has been drained &
refilled several times. You should be able to vent most of the air through the pump vent screw. Loosen the screw and run the boiler. Put a container or piece of rag under the pump to catch the drips. Ahh, I didn't know they had one, i'll have a look tomorrow :-) (only ever had a combi before this) |
#15
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Does anyone happen to have a manual for one of these to hand please ?
Email or ring up Glowworm. They sent me a copy for mine PDQ. OK thanks for that - for some reason I thought they'd gone out of business ! |
#16
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
In message ,
Colin Wilson o.uk writes Does anyone happen to have a manual for one of these to hand please ? Email or ring up Glowworm. They sent me a copy for mine PDQ. OK thanks for that - for some reason I thought they'd gone out of business ! Just hiding behind a hyphen http://www.glow-worm.co.uk/ -- geoff |
#17
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() |