Hi there,

We have decided to fit the fan in our bathroom in the ceiling, but we
are not 100% sure about what kind of extraction system is needed.

The plan is to fit a 6" in line fan in the roof and vent it like this:

http://www.tlc-direct.co.uk/Images/P...e_3/BGSF2X.JPG

But we were after a fan that has a humidity sensor/ movement sensor
for fully automatic operation but I cannot find an in line model like
this.

Could we get a 6" centrifugal fan and vent it in the same way?

If so what are the advantages/dis-advantages of the two solution.
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,538
Default Extractor fan solution sought

David coughed up some electrons that declared:

Hi there,

We have decided to fit the fan in our bathroom in the ceiling, but we
are not 100% sure about what kind of extraction system is needed.

The plan is to fit a 6" in line fan in the roof and vent it like this:

http://www.tlc-direct.co.uk/Images/P...e_3/BGSF2X.JPG

But we were after a fan that has a humidity sensor/ movement sensor
for fully automatic operation but I cannot find an in line model like
this.

Could we get a 6" centrifugal fan and vent it in the same way?

If so what are the advantages/dis-advantages of the two solution.


Can you get a standard humidistat/PIR and use them to control the axial
fan - that's what I'd do.

Cheers

Tim
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25,191
Default Extractor fan solution sought

David wrote:

We have decided to fit the fan in our bathroom in the ceiling, but we
are not 100% sure about what kind of extraction system is needed.

The plan is to fit a 6" in line fan in the roof and vent it like this:

http://www.tlc-direct.co.uk/Images/P...e_3/BGSF2X.JPG

But we were after a fan that has a humidity sensor/ movement sensor
for fully automatic operation but I cannot find an in line model like
this.



An inline fan with such facilities would be kind of pointless - unless
you want it to sense the humidity of your loft rather than the bathroom.
;-)

What you need is a standalone sensor like this :

http://www.tlc-direct.co.uk/Products/BGREMHM.html

That also puts the humidity control within reach rather than on the
ceiling or in the loft.

You can parallel a standalone PIR with the above as well if you want
motion detection as well.

Could we get a 6" centrifugal fan and vent it in the same way?


You could...

If so what are the advantages/dis-advantages of the two solution.


Advantages of inline: freedom to chose an inlet vent of your choice
(TLC do a nice shower light combined vent for example), quieter
operation with less vibration. Pair it with whatever controls you fancy.

CF fan: not much to recommended it except you could possibly get a "one
box" solution with a built in humidistat (which would be at ceiling level)

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 4,010
Default Extractor fan solution sought

John Rumm wrote:
David wrote:

We have decided to fit the fan in our bathroom in the ceiling, but we
are not 100% sure about what kind of extraction system is needed.

The plan is to fit a 6" in line fan in the roof and vent it like
this: http://www.tlc-direct.co.uk/Images/P...e_3/BGSF2X.JPG

But we were after a fan that has a humidity sensor/ movement sensor
for fully automatic operation but I cannot find an in line model like
this.



An inline fan with such facilities would be kind of pointless - unless
you want it to sense the humidity of your loft rather than the
bathroom. ;-)


It's sealed from the loft by the ducting....


--
Phil L
RSRL Tipster Of The Year 2008


  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25,191
Default Extractor fan solution sought

Phil L wrote:
John Rumm wrote:
David wrote:

We have decided to fit the fan in our bathroom in the ceiling, but we
are not 100% sure about what kind of extraction system is needed.

The plan is to fit a 6" in line fan in the roof and vent it like
this: http://www.tlc-direct.co.uk/Images/P...e_3/BGSF2X.JPG

But we were after a fan that has a humidity sensor/ movement sensor
for fully automatic operation but I cannot find an in line model like
this.


An inline fan with such facilities would be kind of pointless - unless
you want it to sense the humidity of your loft rather than the
bathroom. ;-)


It's sealed from the loft by the ducting....


So you would be sensing the humidity in the duct in the loft then...
still not much use if you want to know the humidity in the bathroom.

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/


  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 382
Default Extractor fan solution sought

On 23 Mar, 21:37, John Rumm wrote:
David wrote:
We have decided to fit the fan in our bathroom in the ceiling, but we
are not 100% sure about what kind of extraction system is needed.


The plan is to fit a 6" in line fan in the roof and vent it like this:


http://www.tlc-direct.co.uk/Images/P...e_3/BGSF2X.JPG


But we were after a fan that has a humidity sensor/ movement sensor
for fully automatic operation but I cannot find an in line model like
this.


An inline fan with such facilities would be kind of pointless - unless
you want it to sense the humidity of your loft rather than the bathroom.
;-)

What you need is a standalone sensor like this :

http://www.tlc-direct.co.uk/Products/BGREMHM.html

That also puts the humidity control within reach rather than on the
ceiling or in the loft.

You can parallel a standalone PIR with the above as well if you want
motion detection as well.

Could we get a 6" centrifugal fan and vent it in the same way?


You could...

If so what are the advantages/dis-advantages of the two solution.


Advantages of inline: freedom to chose an inlet vent of your choice
(TLC do a nice shower light combined vent for example), quieter
operation with less vibration. Pair it with whatever controls you fancy.

CF fan: not much to recommended it except you could possibly get a "one
box" solution with a built in humidistat (which would be at ceiling level)

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/


Thanks for that.

I asked my Dad and we have decided to have just a PIR sensor, my Dad
says it should help to extract "fumes" when people use the toilet :-)

The bathroom is 9 meters squared, will a 5" fan be sufficient?

There is a trickle vent and a gap under the door.

AIUI the fan is activated by the PIR sensor, and then runs for a set
time.

Will I need a separate timer?

Your help is appreciated.




  #7   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25,191
Default Extractor fan solution sought

David wrote:

I asked my Dad and we have decided to have just a PIR sensor, my Dad
says it should help to extract "fumes" when people use the toilet :-)

The bathroom is 9 meters squared, will a 5" fan be sufficient?


IIRC The requirement for a bathroom fan is a flow of 15 litres per
second. Most fans will be able to do that.

There is a trickle vent and a gap under the door.

AIUI the fan is activated by the PIR sensor, and then runs for a set
time.


Yup - as long as it has a permanent live as well as a switched one from
the PIR it should run on for a user selectable time. Note you will also
need a three pole isolator switch in the feed to the fan. If this is not
going to be in the same room as the fan then it should be one that can
be locked off.

Will I need a separate timer?


Not if you get a timer fan...



--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
  #8   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 14,085
Default Extractor fan solution sought

On Tue, 24 Mar 2009 02:58:30 +0000, John Rumm wrote:

IIRC The requirement for a bathroom fan is a flow of 15 litres per
second. Most fans will be able to do that.


Fan sizeing is normally derived from room volume and so many changes per
hour. Fans are rated normally rated in cubic meters per hour. 15l/s is
54m^3/hr. *IIRC* bathrooms are reckoned to need 5 to 10 changes/hr so a
54m^3/hr fan is suitable for a tiny bathroom.

--
Cheers
Dave.



  #9   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25,191
Default Extractor fan solution sought

Dave Liquorice wrote:
On Tue, 24 Mar 2009 02:58:30 +0000, John Rumm wrote:

IIRC The requirement for a bathroom fan is a flow of 15 litres per
second. Most fans will be able to do that.


Fan sizeing is normally derived from room volume and so many changes per
hour. Fans are rated normally rated in cubic meters per hour. 15l/s is
54m^3/hr. *IIRC* bathrooms are reckoned to need 5 to 10 changes/hr so a
54m^3/hr fan is suitable for a tiny bathroom.


I just had a look through part F of the building regs, and the only
mention of data for bathroom intermittent mechanical extraction is the
15 l/s figure - they don't seem to take into account the room volume.

If you apply your 54 m^3 to a room of say 3x2x2m, that does in fact give
you 4.5 air changes per hour, which seems toward the upper end of what
would be required in a bathroom - especially without heat recovery.

Anecdotally, I have used a 4" humidistat fan in a bathroom with a high
pressure shower. I found that it would keep most of the visible steam
under control during the shower, and would have the room visibly clear
within 5 mins or finishing. It would then take 20 - 45 mins to dry the
all the room surfaces after that (that was all tiled, with two outside
non cavity walls).


--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
  #10   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 382
Default Extractor fan solution sought

On 24 Mar, 02:58, John Rumm wrote:
David wrote:
I asked my Dad and we have decided to have just a PIR sensor, my Dad
says it should help to extract "fumes" when people use the toilet :-)


The bathroom is 9 meters squared, will a 5" fan be sufficient?


IIRC The requirement for a bathroom fan is a flow of 15 litres per
second. Most fans will be able to do that.

There is a trickle vent and a gap under the door.


AIUI the fan is activated by the PIR sensor, and then runs for a set
time.


Yup - as long as it has a permanent live as well as a switched one from
the PIR it should run on for a user selectable time. Note you will also
need a three pole isolator switch in the feed to the fan. If this is not
going to be in the same room as the fan then it should be one that can
be locked off.

Will I need a separate timer?


Not if you get a timer fan...

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/


So what I need is a good 5" in line fan with a timer, PIR sensor and
ducting etc.

Can you recommend me a good PIR sensor and in line fan please?

I understand the good brands are Xpelair and Vent axia.




Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
email extractor , site , solutions , email based marketing , email marketing solution , email extractor , newsletter software , mass email , e-mail marketing , email marketing solutions , bulk email software , web advertising , email marketing , mark Nuclear Incorporation. www.nuclear-inc.com UK diy 0 April 5th 07 09:31 PM
Toilet extractor fan solution after extension - carbon filter? [email protected] UK diy 3 April 29th 05 05:56 PM
Solution for Bathroom extractor???? John Borman UK diy 5 December 30th 04 08:38 PM
Condensation – Is this a good solution? - Advice Sought Robin Smith UK diy 14 December 27th 03 09:48 PM
33" Mitsubishi tv - help sought kasstzam Electronics Repair 2 November 26th 03 01:22 AM


All times are GMT +1. The time now is 08:15 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"