  #1   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,283
Default Pipe Leak in Solid Floor - Suggestions Please

Hi all

OK so now I am well passed the end of the old teather!
Bought house in 2002 and discovered that damp patch in dining room was not
due to patio door problems but a leaking pipe in the solid concrete floor.
So broke out top of channel and repaired leak in hot water feed for the
existing kitchen extension.
The damage was a broken elbow that had obviously been leaking a fair while
due to limescale build up on the face of the fitting. The elbow was
replaced with a formed bend for better flexibility.
The floor was left uncovered for a good while and the top of the slab
appeared completely dry.
Last year we decorated the room and finally got carpet down.
Over the weekend I noticed a raised bit of floor toward one corner, peeled
back the carpet to find that some infill concrete has "blown" due to damp
and there is a film of water on the bottom of the underlay.

So the questions a

Has anyone had serious leaks into a concrete floor?
Could the appearance of water be a result of the CH driving previously
leaked water to the surface?
How can I find the source of another leak if there is one?
I cannot hear water running when all taps etc are off.
The CH header tank does not appear to drop significantly if the ball is tied
up.
Within the dining room floor there are CH flow/return pipes, hot (gravity
fed) and cold (mains fed) water to the kitchen.

Any suggestions on means of locating/testing for leaks would be appreciated.
The fact that the room is the most recently refurbished makes me reluctant
to start hacking up floors/destroying box work etc. SWMBO has not yet been
appraised of the issue!

Final question:

Should insurance cover this? No plumbing work has been carried out in the
last 2 years!

TIA

Phil



  #2   Report Post  
Posted to uk.d-i-y
Rod Rod is offline
external usenet poster
 
Posts: 2,892
Default Pipe Leak in Solid Floor - Suggestions Please

TheScullster wrote:
Hi all

OK so now I am well passed the end of the old teather!
Bought house in 2002 and discovered that damp patch in dining room was not
due to patio door problems but a leaking pipe in the solid concrete floor.
So broke out top of channel and repaired leak in hot water feed for the
existing kitchen extension.
The damage was a broken elbow that had obviously been leaking a fair while
due to limescale build up on the face of the fitting. The elbow was
replaced with a formed bend for better flexibility.
The floor was left uncovered for a good while and the top of the slab
appeared completely dry.
Last year we decorated the room and finally got carpet down.
Over the weekend I noticed a raised bit of floor toward one corner, peeled
back the carpet to find that some infill concrete has "blown" due to damp
and there is a film of water on the bottom of the underlay.

So the questions a

Has anyone had serious leaks into a concrete floor?
Could the appearance of water be a result of the CH driving previously
leaked water to the surface?
How can I find the source of another leak if there is one?
I cannot hear water running when all taps etc are off.
The CH header tank does not appear to drop significantly if the ball is tied
up.
Within the dining room floor there are CH flow/return pipes, hot (gravity
fed) and cold (mains fed) water to the kitchen.

Any suggestions on means of locating/testing for leaks would be appreciated.
The fact that the room is the most recently refurbished makes me reluctant
to start hacking up floors/destroying box work etc. SWMBO has not yet been
appraised of the issue!

Final question:

Should insurance cover this? No plumbing work has been carried out in the
last 2 years!

TIA

Phil


When you repaired the pipe, did you then simply re-fill the hole with
cement/concrete? Was the pipe protected in any way either originally or
in your repair?

Is there any possibility of bypassing that leg of pipework? Maybe using
a completely different route? Maybe using plastic pipe would make a
route viable that was not sensible when the extension was built?

Are you certain of the route the entire pipework takes through the
concrete? I would hazard a guess that if one joint has failed, any
others that exist could also fail and would not wish to trust any that
might exist. If unprotected, I would not even wish to trust the
straight, unjointed pipework in the long term.

--
Rod

Hypothyroidism is a seriously debilitating condition with an insidious
onset.
Although common it frequently goes undiagnosed.
www.thyromind.info www.thyroiduk.org www.altsupportthyroid.org
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,283
Default Pipe Leak in Solid Floor - Suggestions Please


"Rod" wrote


When you repaired the pipe, did you then simply re-fill the hole with
cement/concrete? Was the pipe protected in any way either originally or in
your repair?


The pipe was carefully wrapped in dpm material before concreting over.
Originally, the u/ground piping is all wrapped in a hession type sleave in a
channel of sand.


Is there any possibility of bypassing that leg of pipework? Maybe using a
completely different route? Maybe using plastic pipe would make a route
viable that was not sensible when the extension was built?


Yes that is possibility which I have made provision for, but I'm not sure if
that pipe is leaking elsewhere or not.
It might be another pipe that is at fault.
Or maybe there isn't a leak there now and the moisture that is surfacing is
water from the original leak that is trapped around/under the slab.
The problem is, how do I confirm what's what?


Are you certain of the route the entire pipework takes through the
concrete? I would hazard a guess that if one joint has failed, any others
that exist could also fail and would not wish to trust any that might
exist. If unprotected, I would not even wish to trust the straight,
unjointed pipework in the long term.

Phil


  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 9,560
Default Pipe Leak in Solid Floor - Suggestions Please

On Nov 3, 1:55*pm, "TheScullster" wrote:
"Rod" wrote


The pipe was carefully wrapped in dpm material before concreting over.
Originally, the u/ground piping is all wrapped in a hession type sleave in a
channel of sand.



Is there any possibility of bypassing that leg of pipework? Maybe using a
completely different route? Maybe using plastic pipe would make a route
viable that was not sensible when the extension was built?


Yes that is possibility which I have made provision for, but I'm not sure if
that pipe is leaking elsewhere or not.
It might be another pipe that is at fault.
Or maybe there isn't a leak there now and the moisture that is surfacing is
water from the original leak that is trapped around/under the slab.
The problem is, how do I confirm what's what?


If you dont want to dig up the floor or bypass all buried pipes with
surface plumbing, you might put some dye in the CH primary. I'm
guessing it would take a fair while to know if that dye had come
through the floor or not, so not exactly a quick solution, but
certainly an easy option - in a month's time you'll know what to
bypass and what not to.

You may well find that the rubber underlay has stopped the leaking
water from evaporating from the slab, and that using porous flooring
leaves the slab dry to the touch, once its dried off initially.


NT
  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 666
Default Pipe Leak in Solid Floor - Suggestions Please


"TheScullster" wrote in message
. uk...

"Rod" wrote


When you repaired the pipe, did you then simply re-fill the hole with
cement/concrete? Was the pipe protected in any way either originally or

in
your repair?


The pipe was carefully wrapped in dpm material before concreting over.
Originally, the u/ground piping is all wrapped in a hession type sleave in

a
channel of sand.


Is there any possibility of bypassing that leg of pipework? Maybe using

a
completely different route? Maybe using plastic pipe would make a route
viable that was not sensible when the extension was built?


Yes that is possibility which I have made provision for, but I'm not sure

if
that pipe is leaking elsewhere or not.
It might be another pipe that is at fault.
Or maybe there isn't a leak there now and the moisture that is surfacing

is
water from the original leak that is trapped around/under the slab.
The problem is, how do I confirm what's what?


Are you certain of the route the entire pipework takes through the
concrete? I would hazard a guess that if one joint has failed, any

others
that exist could also fail and would not wish to trust any that might
exist. If unprotected, I would not even wish to trust the straight,
unjointed pipework in the long term.

Phil



Hey Scullster, face it mate. The only sure way to find out what's what, is
to dig it out and have look. What damage has been caused by this problem?
Ask your insurance if they will cover it, before you go digging it all out.

Once you fix what ever it is, it seems that the protection methods currently
being used are not up the job. When the fix has been done, try boxing
around the pipework with loft lagging and sand, before making good the
floor.

How deep are the pipes in the floor? Is the room heated throughout the
night? What composition is the floor, and is it laid directly on the
groundwork? How close together are the pipes? Can the cold feed use
residual heat from the central heating runs to keep it from freezing?

The best underfloor system I've seen, was a trough containing the pipes, a
layer of sand, a layer of loft lagging, pipe runs, a layer of lagging, and
topped off with narrow paving slabs an inch or two below floor level, then
skimmed over to make good. So the pipes were not hard packed in the floor
at all. Amazing that it still has no problems after thirty years of
continuous use under our workshop floor. I have also seen it done with
brick capping and it has had no problems for years also.

Something could be wrong with the pipework in the floor, and you'd better
get is sorted or it is going to recur. It may take three years the next
time, but what if it happens again. Get it fixed with at least a 20 year
guarantee on it.

Good luck with it.



  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 9,045
Default Pipe Leak in Solid Floor - Suggestions Please

BigWallop wrote:
"TheScullster" wrote in message
. uk...
"Rod" wrote

When you repaired the pipe, did you then simply re-fill the hole with
cement/concrete? Was the pipe protected in any way either originally or

in
your repair?

The pipe was carefully wrapped in dpm material before concreting over.
Originally, the u/ground piping is all wrapped in a hession type sleave in

a
channel of sand.

Is there any possibility of bypassing that leg of pipework? Maybe using

a
completely different route? Maybe using plastic pipe would make a route
viable that was not sensible when the extension was built?

Yes that is possibility which I have made provision for, but I'm not sure

if
that pipe is leaking elsewhere or not.
It might be another pipe that is at fault.
Or maybe there isn't a leak there now and the moisture that is surfacing

is
water from the original leak that is trapped around/under the slab.
The problem is, how do I confirm what's what?

Are you certain of the route the entire pipework takes through the
concrete? I would hazard a guess that if one joint has failed, any

others
that exist could also fail and would not wish to trust any that might
exist. If unprotected, I would not even wish to trust the straight,
unjointed pipework in the long term.

Phil



Hey Scullster, face it mate. The only sure way to find out what's what, is
to dig it out and have look. What damage has been caused by this problem?
Ask your insurance if they will cover it, before you go digging it all out.

Once you fix what ever it is, it seems that the protection methods currently
being used are not up the job. When the fix has been done, try boxing
around the pipework with loft lagging and sand, before making good the
floor.


Be sure its not merely a concrete slab lying on wet ground with no
membrane under.

But yes, dig the ******* up.
  #7   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 16
Default Pipe Leak in Solid Floor - Suggestions Please

On 3 Nov, 18:16, "Fred" wrote:
"TheScullster" wrote in message

. uk...

Hi all


The CH header tank does not appear to drop significantly if the ball is
tied up.


How much, if tied up for a week or 2, how much does the level go down?


Can you not isolate each pipe in turn and pressure test it with a car
pump and a pressure gauge bought for the purpose from Screwfix?

http://www.screwfix.com/prods/72940/...ssure-Test-Kit

You would then be able to verify the integrity of the pipework without
digging up the floor - providing you can find somewhere to connect the
gauge for each of the pipes you mention (CH Flow and Return should be
achievable, DHW should also be possible, Mains cold water feed may be
a bit more problematical).

A bit of tinkering here and there to boxing in is a hell of a lot less
work than digging up an entire floor.

I would be very surprised if the current damp problem is caused by
previously leaked water being driven to the surface, simply due to the
sheer volume of water involved if, as you say, the underlay is
literally wringing wet.

I wouldn't rule out the possibility that the dampness is caused by an
entirely new problem.

Luke
  #8   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 9,560
Default Pipe Leak in Solid Floor - Suggestions Please

On Nov 3, 10:31*pm, Wingedcat wrote:
On 3 Nov, 18:16, "Fred" wrote:

"TheScullster" wrote in message


.uk...


Hi all


The CH header tank does not appear to drop significantly if the ball is
tied up.


How much, if tied up for a week or 2, how much does the level go down?


Can you not isolate each pipe in turn and pressure test it with a car
pump and a pressure gauge bought for the purpose from Screwfix?

http://www.screwfix.com/prods/72940/...-Tools/Pressur...

You would then be able to verify the integrity of the pipework without
digging up the floor - providing you can find somewhere to connect the
gauge for each of the pipes you mention (CH Flow and Return should be
achievable, DHW should also be possible, Mains cold water feed may be
a bit more problematical).

A bit of tinkering here and there to boxing in is a hell of a lot less
work than digging up an entire floor.


Running a surface pipe is a fair bit less work than digging it up.


I would be very surprised if the current damp problem is caused by
previously leaked water being driven to the surface, simply due to the
sheer volume of water involved if, as you say, the underlay is
literally wringing wet.

I wouldn't rule out the possibility that the dampness is caused by an
entirely new problem.

Luke


quite.


NT
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Laying gas pipe in solid floor. tonyjeffs UK diy 2 September 22nd 07 06:00 PM
When to lay the floor tiles and shower trays on a solid floor. Sparks UK diy 2 September 11th 06 11:01 AM
Installing gas pipe under solid floor Tournifreak UK diy 11 September 21st 05 10:51 PM
Fitting floor boards over solid concrete floor CharlieB UK diy 1 November 27th 04 08:10 PM
Water leak around tub surround. Suggestions? MAG Home Repair 3 May 31st 04 08:46 PM


All times are GMT +1. The time now is 02:15 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"